Javascript must be enabled to continue!
Measurement uncertainty analysis for bulk current injection calibration process
View through CrossRef
Abstract
In this article, the setup and calibration process of the BCI test according to ISO 11452-4 and a general evaluation and calculation of the total measurement uncertainty is presented. This sample measurement uncertainty calculations can be used as the measurement uncertainty calculations, which are absent in ISO 11452 standards. After the introduction into the measurement uncertainty calculation, the calibration process is critically examined on many sources of measurement uncertainties and mismatches inside the setup, which have significant impact on the calibration and also on the testing process. Additionally, new sources of uncertainty are evaluated in this paper, which can have a high impact on the calibration and testing process. This sample measurement uncertainty calculations can be used as the measurement uncertainty calculations, which are absent in ISO 11452 standards. With all detected sources of uncertainties, the measurement uncertainty calculation models can be used for other international standards with similar calibration and test processes, which are used for testing devices for different fields of application, and by calibration and testing laboratories, to improve the reproducibility of the calibration and testing process.
Walter de Gruyter GmbH
Title: Measurement uncertainty analysis for bulk current injection calibration process
Description:
Abstract
In this article, the setup and calibration process of the BCI test according to ISO 11452-4 and a general evaluation and calculation of the total measurement uncertainty is presented.
This sample measurement uncertainty calculations can be used as the measurement uncertainty calculations, which are absent in ISO 11452 standards.
After the introduction into the measurement uncertainty calculation, the calibration process is critically examined on many sources of measurement uncertainties and mismatches inside the setup, which have significant impact on the calibration and also on the testing process.
Additionally, new sources of uncertainty are evaluated in this paper, which can have a high impact on the calibration and testing process.
This sample measurement uncertainty calculations can be used as the measurement uncertainty calculations, which are absent in ISO 11452 standards.
With all detected sources of uncertainties, the measurement uncertainty calculation models can be used for other international standards with similar calibration and test processes, which are used for testing devices for different fields of application, and by calibration and testing laboratories, to improve the reproducibility of the calibration and testing process.
Related Results
Overview of Key Zonal Water Injection Technologies in China
Overview of Key Zonal Water Injection Technologies in China
Abstract
Separated layer water injection is the important technology to realize the oilfield long-term high and stable yield. Through continuous researches and te...
Reserves Uncertainty Calculation Accounting for Parameter Uncertainty
Reserves Uncertainty Calculation Accounting for Parameter Uncertainty
Abstract
An important goal of geostatistical modeling is to assess output uncertainty after processing realizations through a transfer function, in particular, to...
Dynamic calibration method for track geometry measurement system-a case study in China
Dynamic calibration method for track geometry measurement system-a case study in China
Abstract
With the rapid development of railway construction, the mileage of railway detection has increased dramatically, and railway companies have higher requireme...
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
Optimal Injection Parameters for Enhancing Coalbed Methane Recovery: A Simulation Study from the Shizhuang Block, Qinshui Basin, China
The injection of N2 into coal reservoir has great potential in improving recovery of coalbed methane (CBM). In this study, a numerical model was established based on the GEM compon...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Application of Novel Techniques to Fractured Injection Diagnostics in Waterflood Developments
Application of Novel Techniques to Fractured Injection Diagnostics in Waterflood Developments
Abstract
Controlled injection at high rates predominantly under fracture regime has been identified at the onset of most waterflood field developments as being cruci...
Features of measurement uncertainty evaluation during calibration of digital ohmmeters
Features of measurement uncertainty evaluation during calibration of digital ohmmeters
The scheme for transferring the size of the unit of resistance during the calibration of digital ohmmeters at direct current is considered. The procedure for the measurement uncert...
Control of Water Injection into a Layered Formation
Control of Water Injection into a Layered Formation
Abstract
In previously published work, we have analyzed transient injection of water from a growing vertical hydrofracture into a low-permeability compressible rock ...