Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Signal alignment for cross-datasets in P300 brain-computer interfaces

View through CrossRef
Abstract Objective. Transfer learning has become an important issue in the brain-computer interface (BCI) field, and studies on subject-to-subject transfer within the same dataset have been performed. However, few studies have been performed on dataset-to-dataset transfer, including paradigm-to-paradigm transfer. In this study, we propose a signal alignment (SA) for P300 event-related potential (ERP) signals that is intuitive, simple, computationally less expensive, and can be used for cross-dataset transfer learning. Approach. We proposed a linear SA that uses the P300’s latency, amplitude scale, and reverse factor to transform signals. For evaluation, four datasets were introduced (two from conventional P300 Speller BCIs, one from a P300 Speller with face stimuli, and the last from a standard auditory oddball paradigm). Results. Although the standard approach without SA had an average precision (AP) score of 25.5%, the approach demonstrated a 35.8% AP score, and we observed that the number of subjects showing improvement was 36.0% on average. Particularly, we confirmed that the Speller dataset with face stimuli was more comparable with other datasets. Significance. We proposed a simple and intuitive way to align ERP signals that uses the characteristics of ERP signals. The results demonstrated the feasibility of cross-dataset transfer learning even between datasets with different paradigms.
Title: Signal alignment for cross-datasets in P300 brain-computer interfaces
Description:
Abstract Objective.
Transfer learning has become an important issue in the brain-computer interface (BCI) field, and studies on subject-to-subject transfer within the same dataset have been performed.
However, few studies have been performed on dataset-to-dataset transfer, including paradigm-to-paradigm transfer.
In this study, we propose a signal alignment (SA) for P300 event-related potential (ERP) signals that is intuitive, simple, computationally less expensive, and can be used for cross-dataset transfer learning.
Approach.
We proposed a linear SA that uses the P300’s latency, amplitude scale, and reverse factor to transform signals.
For evaluation, four datasets were introduced (two from conventional P300 Speller BCIs, one from a P300 Speller with face stimuli, and the last from a standard auditory oddball paradigm).
Results.
Although the standard approach without SA had an average precision (AP) score of 25.
5%, the approach demonstrated a 35.
8% AP score, and we observed that the number of subjects showing improvement was 36.
0% on average.
Particularly, we confirmed that the Speller dataset with face stimuli was more comparable with other datasets.
Significance.
We proposed a simple and intuitive way to align ERP signals that uses the characteristics of ERP signals.
The results demonstrated the feasibility of cross-dataset transfer learning even between datasets with different paradigms.

Related Results

Brain Organoids, the Path Forward?
Brain Organoids, the Path Forward?
Photo by Maxim Berg on Unsplash INTRODUCTION The brain is one of the most foundational parts of being human, and we are still learning about what makes humans unique. Advancements ...
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED]➢Item Name - Gro-X Brain➢ Creation - Natural Organic Compound➢ Incidental Effects - NA➢ Accessibility - Online➢ Rating - ⭐⭐⭐⭐⭐➢ Click Here To Visit - Official Website - ...
P300 Energy Loss in Aging and Alzheimer's Disease
P300 Energy Loss in Aging and Alzheimer's Disease
The amplitude of the event-related potential P300 component is sensitive to aging and Alzheimer's disease (AD). Using a standard 20-electrode configuration, the P300 was measured d...
Inhibition of p300 activity attenuates intimal hyperplasia following arterial injury
Inhibition of p300 activity attenuates intimal hyperplasia following arterial injury
Background p300 has been regarded as a potential source for cell proliferation, survival, growth, and differentiation by functioning as a transcriptional bridge, ...
P300 and decision-making in neuromarketing
P300 and decision-making in neuromarketing
Neuromarketing provides insights into consumers' decision-making that traditional marketing test methods cannot offer. The foundation in the process of decision-making is P300. Thu...
STAT3 Protein–Protein Interaction Analysis Finds P300 as a Regulator of STAT3 and Histone 3 Lysine 27 Acetylation in Pericytes
STAT3 Protein–Protein Interaction Analysis Finds P300 as a Regulator of STAT3 and Histone 3 Lysine 27 Acetylation in Pericytes
Background: Signal transducer and activator of transcription 3 (STAT3) is a member of the cytoplasmic inducible transcription factors and plays an important role in mediating signa...
A novel EEG-based spelling system using N100 and P300
A novel EEG-based spelling system using N100 and P300
P300-speller is one of the most popular EEG-based spelling systems proposed by Farwell and Donchin. P300-speller has a 6×6 character matrix and requires at least 12 flash...

Back to Top