Measurement of Spectral Match and Spatial Non-uniformity for Indoor Solar Simulator

View through CrossRef
This paper presents a study on the measurement of spectral match and spatial non-uniformity of the indoor solar simulator available in Universiti Teknikal Malaysia Melaka (UTeM). This indoor solar simulator which was successfully fabricated at the Applied Solar Energy Laboratory (ASEL) had used the quartz tungsten halogen lamp as its only light source. Upon its fabrication, the reliability of ASEL’s solar simulator has not been proved yet as there is no concrete evidence that it had followed the international standard set for solar simulator. Therefore, the motivation of this study had been set to determine the characteristics of the indoor solar simulator in term of its spectral match and spatial non-uniformity. The literature review conducted has revealed that there are few methods that been practiced to determine both cases. For the spectral match test, the experimental works chosen for this research was the mathematical modelling method. Meanwhile, for the spatial non-uniformity test, irradiance mapping method was used where the reading of irradiance intensity at each coordinate across the map was measured. At the end of this study, it shows that at 400-500nm and 500-600 wavelength range, the value of spectral match value obtained was 0.40 and 1.46 respectively; whereas for 600-700nm range, the spectral match measured was beyond the standard range set. On the other hand, this study also reveals that the solar simulator was capable to produce 8.42% of spatial non-uniformity across the tested area of 104cm x 80cm. The average irradiance intensity recorded for this test was 981.98 W/m2.
Title: Measurement of Spectral Match and Spatial Non-uniformity for Indoor Solar Simulator
Description:
This paper presents a study on the measurement of spectral match and spatial non-uniformity of the indoor solar simulator available in Universiti Teknikal Malaysia Melaka (UTeM).
This indoor solar simulator which was successfully fabricated at the Applied Solar Energy Laboratory (ASEL) had used the quartz tungsten halogen lamp as its only light source.
Upon its fabrication, the reliability of ASEL’s solar simulator has not been proved yet as there is no concrete evidence that it had followed the international standard set for solar simulator.
Therefore, the motivation of this study had been set to determine the characteristics of the indoor solar simulator in term of its spectral match and spatial non-uniformity.
The literature review conducted has revealed that there are few methods that been practiced to determine both cases.
For the spectral match test, the experimental works chosen for this research was the mathematical modelling method.
Meanwhile, for the spatial non-uniformity test, irradiance mapping method was used where the reading of irradiance intensity at each coordinate across the map was measured.
At the end of this study, it shows that at 400-500nm and 500-600 wavelength range, the value of spectral match value obtained was 0.
40 and 1.
46 respectively; whereas for 600-700nm range, the spectral match measured was beyond the standard range set.
On the other hand, this study also reveals that the solar simulator was capable to produce 8.
42% of spatial non-uniformity across the tested area of 104cm x 80cm.
The average irradiance intensity recorded for this test was 981.
98 W/m2.

Related Results

Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
City dwellers are increasingly exposed to summer heat due to climate change and urbanization. Summer heat, which causes heat stress, is intensified especially at night in urban are...
Simulator approaches in otorhinolaryngology ‐ Looking beyond the ophthalmological horizon
Simulator approaches in otorhinolaryngology ‐ Looking beyond the ophthalmological horizon
Purpose: To improve medical students' learning of handheld otoscopy technique and findings based on a standardized simulator‐based procedure.Methods: A group of 120 medical student...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract  Introduction Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
Parameterized Strings: Algorithms and Applications
Parameterized Strings: Algorithms and Applications
The parameterized string (p-string), a generalization of the traditional string, is composed of constant and parameter symbols. A parameterized match (p-match) exists between two p...
The indoor mycobiome of daycare centers is affected by occupancy and climate
The indoor mycobiome of daycare centers is affected by occupancy and climate
AbstractMany children spend considerable time in daycare centers and may here be influenced by indoor microorganisms, including fungi. In this study, we investigate the indoor myco...
Application of Virtual Reality Technology in Nuclear Power Plant Control Room Simulator
Application of Virtual Reality Technology in Nuclear Power Plant Control Room Simulator
Main control room simulator is widely used in design verification and operator training for nuclear power plant. The simulator needs to implement the arrangement, environment, huma...
Indoor and outdoor air quality relationships modelling
Indoor and outdoor air quality relationships modelling
Particulate matter (PM) related ambient pollution has emerged as one of the most significant environmental and human health issues during the last decades. Thus, ambient PM concent...

Back to Top