2408How can we improve the success of cardiac resynchronization therapy implantation?

View through CrossRef
Abstract Introduction The left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is one of the most important and complex steps, leading to implantation failure in 10–15% of cases. New LV lead implantation techniques are needed to allow better resynchronization and decrease mortality and hospitalizations. Objectives To evaluate the efficacy and safety of the snare technique in the LV lead implantation in cases of standard technique failure. Methods Prospective, single-center study of patients undergoing CRT implantation since 2015. Demographic, clinical, and CRT implantation techniques were evaluated, taking into account the vessel with the best resynchronization capacity. The snare technique, through the active traction of the lead to the target vessel, was used in cases of standard technique failure. Time to surgical revision and mortality were evaluated by the Cox regression and Kaplan-Meier methods. Major complications, defined as reasons for prolonged hospitalization or potentially fatal, were evaluated. Results 486 CRTs were implanted since 2015 (73.9% males, 73 years (IQR 66–79), median follow-up of 487 days (IQR 175–749), 91% for heart failure, dilated cardiomyopathy in 55.4%. In 17.3% of these patients (n=84), LV lead was implanted through the snare technique, 94% of the cases in a lateral vein, 100% efficacy in the positioning in the intended vessel. Comparing the snare technique with the standard technique, patients implanted with snare presented a lower all-cause surgical revision (HR 0.31, 95% CI 0.094–0.98, p=0.035), with a number needed to treat of 25 patients to prevent one surgical revision, and a lower revision rate due to LV lead implant failure/dislodgement (Log Rank 5.1, p=0.024). There were no surgical revisions for LV lead repositioning in patients undergoing the snare technique. The rate of major complications (4.8% vs 3.0%, p=0.41), 30-day mortality (3.5% vs 1.8%, p=0.28) and all-cause mortality (13.1% vs 13.9%, p=0.47) were similar to the standard procedure. Major complications in both groups were pericardial effusion and contrast nephropathy. The snare technique presented a longer procedure duration (104 vs 78 min, p<0.01) and fluoroscopy time (26.6 vs 15.5 min, p<0.01). Over time, there was a learning curve with reduction in procedure duration and fluoroscopy time. Conclusion The snare technique allows LV lead implantation in the vein with the best resynchronization characteristics, increasing the success rate in the implantation of CRT. It also reduced all-cause surgical revisions and surgical revisions due to LV lead implant failure/dislodgement, with a favourable safety profile similar to the standard technique.
Title: 2408How can we improve the success of cardiac resynchronization therapy implantation?
Description:
Abstract Introduction The left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is one of the most important and complex steps, leading to implantation failure in 10–15% of cases.
New LV lead implantation techniques are needed to allow better resynchronization and decrease mortality and hospitalizations.
Objectives To evaluate the efficacy and safety of the snare technique in the LV lead implantation in cases of standard technique failure.
Methods Prospective, single-center study of patients undergoing CRT implantation since 2015.
Demographic, clinical, and CRT implantation techniques were evaluated, taking into account the vessel with the best resynchronization capacity.
The snare technique, through the active traction of the lead to the target vessel, was used in cases of standard technique failure.
Time to surgical revision and mortality were evaluated by the Cox regression and Kaplan-Meier methods.
Major complications, defined as reasons for prolonged hospitalization or potentially fatal, were evaluated.
Results 486 CRTs were implanted since 2015 (73.
9% males, 73 years (IQR 66–79), median follow-up of 487 days (IQR 175–749), 91% for heart failure, dilated cardiomyopathy in 55.
4%.
In 17.
3% of these patients (n=84), LV lead was implanted through the snare technique, 94% of the cases in a lateral vein, 100% efficacy in the positioning in the intended vessel.
Comparing the snare technique with the standard technique, patients implanted with snare presented a lower all-cause surgical revision (HR 0.
31, 95% CI 0.
094–0.
98, p=0.
035), with a number needed to treat of 25 patients to prevent one surgical revision, and a lower revision rate due to LV lead implant failure/dislodgement (Log Rank 5.
1, p=0.
024).
There were no surgical revisions for LV lead repositioning in patients undergoing the snare technique.
The rate of major complications (4.
8% vs 3.
0%, p=0.
41), 30-day mortality (3.
5% vs 1.
8%, p=0.
28) and all-cause mortality (13.
1% vs 13.
9%, p=0.
47) were similar to the standard procedure.
Major complications in both groups were pericardial effusion and contrast nephropathy.
The snare technique presented a longer procedure duration (104 vs 78 min, p<0.
01) and fluoroscopy time (26.
6 vs 15.
5 min, p<0.
01).
Over time, there was a learning curve with reduction in procedure duration and fluoroscopy time.
Conclusion The snare technique allows LV lead implantation in the vein with the best resynchronization characteristics, increasing the success rate in the implantation of CRT.
It also reduced all-cause surgical revisions and surgical revisions due to LV lead implant failure/dislodgement, with a favourable safety profile similar to the standard technique.

Related Results

Predictive value of left atrial remodeling for response to cardiac resynchronization therapy
Predictive value of left atrial remodeling for response to cardiac resynchronization therapy
Aim: Response to cardiac resynchronization therapy varies significantly among patients, with one third of them failing to demonstrate left ventricular reverse ...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
Dual versus conventional cardiac resynchronization: A pilot study
Dual versus conventional cardiac resynchronization: A pilot study
Background: Systolic heart failure treatment now includes cardiac resynchronization therapy (CRT) as a necessary element. CRT has been shown to have advantageous impacts on mortali...
Dual versus conventional cardiac resynchronization: A pilot study
Dual versus conventional cardiac resynchronization: A pilot study
Background: Systolic heart failure treatment now includes cardiac resynchronization therapy (CRT) as a necessary element. CRT has been shown to have advantageous impacts on mortali...
Mediator kinase submodule-dependent regulation of cardiac transcription
Mediator kinase submodule-dependent regulation of cardiac transcription
<p>Pathological cardiac remodeling results from myocardial stresses including pressure and volume overload, neurohumoral activation, myocardial infarction, and hypothyroidism...

Back to Top