Constant-Tissue Model for Comparison of Supine and Prone Breast Coil SNR
View through CrossRef
Recent work has developed supine breast imaging for improved correlation with surgery and comfort but will likely require breast-specific coils to maximize the SNR. Comparing prone and supine SNR can be difficult due to substantial deformation between the positions and heterogeneity of the patient population. We measured SNR in a constant-tissue model to reduce dependence on tissue heterogeneity and provide an overall SNR across the volume of interest. We compared SNR of a novel 60-channel supine coil and a standard prone coil. In the cosntant-tissue images, the supine 60-channel coil increased SNR by 33%, 78% and 80% across 3 volunteers.
Title: Constant-Tissue Model for Comparison of Supine and Prone Breast Coil SNR
Description:
Recent work has developed supine breast imaging for improved correlation with surgery and comfort but will likely require breast-specific coils to maximize the SNR.
Comparing prone and supine SNR can be difficult due to substantial deformation between the positions and heterogeneity of the patient population.
We measured SNR in a constant-tissue model to reduce dependence on tissue heterogeneity and provide an overall SNR across the volume of interest.
We compared SNR of a novel 60-channel supine coil and a standard prone coil.
In the cosntant-tissue images, the supine 60-channel coil increased SNR by 33%, 78% and 80% across 3 volunteers.
Related Results
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Relative SNR Measurement with Supine versus Prone Positioning in Breast MRI
Relative SNR Measurement with Supine versus Prone Positioning in Breast MRI
Motivation: The current imaging setup for breast MRI is for the patient to be in the prone position. Recent coil advancements have enabled fast supine breast imaging, but this is n...
Tissue-Independent SNR Measurement for Supine Breast Coil Assessment
Tissue-Independent SNR Measurement for Supine Breast Coil Assessment
Motivation: Breast MRI typically is performed with a patient in the prone position. Imaging supine would dramatically improve patient comfort and possibly reduce setup and position...
COMPARISON BETWEEN SUPINE POSITION VERSUS PRONE POSITION IN PERCUTANEOUS NEPHROLITHOTOMY: A SINGLE CENTERED ANALYSIS OF 623 CASES
COMPARISON BETWEEN SUPINE POSITION VERSUS PRONE POSITION IN PERCUTANEOUS NEPHROLITHOTOMY: A SINGLE CENTERED ANALYSIS OF 623 CASES
Background: The ideal urological method for treating complex, large renal calculi is Percutaneous nephrolithotomy (PCNL). Its instruments, surgical techniques, and positions have a...
Characterizing the imaging environment for supine breast MRI
Characterizing the imaging environment for supine breast MRI
Abstract
Purpose
Supine breast MRI has the potential to improve over standard prone breast magnetic resonance imaging (MR...
Percutaneous Nephrolithotomy in Supine versus Prone Position in Tertiary Hospital in Mysore: A Prospective Cohort Study
Percutaneous Nephrolithotomy in Supine versus Prone Position in Tertiary Hospital in Mysore: A Prospective Cohort Study
Introduction: Percutaneous Nephrolithotomy (PCNL) is a procedure of choice for large renal calculi. It is a common urological procedure. PCNL can be performed in various positions....
Characterizing B0 field inhomogeneity, B1+ variations, and respiratory motion for breast MRI in the supine position
Characterizing B0 field inhomogeneity, B1+ variations, and respiratory motion for breast MRI in the supine position
Motivation: Supine breast MRI would overcome many drawbacks of prone breast imaging, including patient discomfort, claustrophobia, misalignment with other procedures, and setup tim...