Estimation of Cardiorespiratory fitness using a using a chest mounted accelerometer

View through CrossRef
Abstract   Cardiorespiratory fitness expressed as maximal oxygen consumption (V̇O2 max) is a strong predictor of cardiovascular health. However, quantification of cardiorespiratory fitness by cardiopulmonary exercise (CPX) assessment is complex and costly and therefore not suitable in most clinical settings. In the current study we develop and validate an algorithm for estimation of V̇O2 max using seismocardiography (SCG-V̇O2 max). SCG is measurement of precordial vibrations using an accelerometer. Methods SCG recordings and results from ergometer CPX testing of V̇O2 max in 300 subjects from six clinical studies were combined in a database. 83 subjects underwent repeated measurements sessions across several days. SCG was obtained using a sensitive accelerometer, located on the lower sternum at the Xiphoid protrusion and subjects were placed in a supine position. 5 subjects were excluded due to cardiovascular disease, or missing data. A machine learning algorithm was devolved for estimation of V̇O2 max in a training set including 221 subjects. The remaining 74 subjects were included in a test set for validation. Correlation and accuracy between SCG-V̇O2 max and ergometer CPX V̇O2 max assessed and day to day variation was assessed in subjects who underwent multiple ergometer CPX sessions. Results In 144 recordings from 74 test set subjects SCG-V̇O2 max was 45.0±9.3 ml/min/kg which was comparable to the ergometer CPX V̇O2 max at 44.3±10.1 ml/min/kg (p=0.09) and correlation between ergometer CPX V̇O2 max and SCG-V̇O2 max was r=0.875. Mean average percentage error was 8.7%. Day to day variation measured as the within-subjects-standard-deviation was 1.2 ml/min/kg for SCG-V̇O2 max and 1.7 ml/min/kg for ergometer CPX. Conclusions SCG based estimation of VV̇O2 max is a novel, low cost, easy to use and accurate estimation method of CRF with a high level of reproducibility. SCG-V̇O2 max can potentially facilitate that cardiorespiratory fitness becomes an integrated part of modern health assessment. Funding Acknowledgement Type of funding sources: Private company. Main funding source(s): VentriJect A/S DK
Title: Estimation of Cardiorespiratory fitness using a using a chest mounted accelerometer
Description:
Abstract   Cardiorespiratory fitness expressed as maximal oxygen consumption (V̇O2 max) is a strong predictor of cardiovascular health.
However, quantification of cardiorespiratory fitness by cardiopulmonary exercise (CPX) assessment is complex and costly and therefore not suitable in most clinical settings.
In the current study we develop and validate an algorithm for estimation of V̇O2 max using seismocardiography (SCG-V̇O2 max).
SCG is measurement of precordial vibrations using an accelerometer.
Methods SCG recordings and results from ergometer CPX testing of V̇O2 max in 300 subjects from six clinical studies were combined in a database.
83 subjects underwent repeated measurements sessions across several days.
SCG was obtained using a sensitive accelerometer, located on the lower sternum at the Xiphoid protrusion and subjects were placed in a supine position.
5 subjects were excluded due to cardiovascular disease, or missing data.
A machine learning algorithm was devolved for estimation of V̇O2 max in a training set including 221 subjects.
The remaining 74 subjects were included in a test set for validation.
Correlation and accuracy between SCG-V̇O2 max and ergometer CPX V̇O2 max assessed and day to day variation was assessed in subjects who underwent multiple ergometer CPX sessions.
Results In 144 recordings from 74 test set subjects SCG-V̇O2 max was 45.
0±9.
3 ml/min/kg which was comparable to the ergometer CPX V̇O2 max at 44.
3±10.
1 ml/min/kg (p=0.
09) and correlation between ergometer CPX V̇O2 max and SCG-V̇O2 max was r=0.
875.
Mean average percentage error was 8.
7%.
Day to day variation measured as the within-subjects-standard-deviation was 1.
2 ml/min/kg for SCG-V̇O2 max and 1.
7 ml/min/kg for ergometer CPX.
Conclusions SCG based estimation of VV̇O2 max is a novel, low cost, easy to use and accurate estimation method of CRF with a high level of reproducibility.
SCG-V̇O2 max can potentially facilitate that cardiorespiratory fitness becomes an integrated part of modern health assessment.
Funding Acknowledgement Type of funding sources: Private company.
Main funding source(s): VentriJect A/S DK.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Chest Wall Hydatid Cysts: A Systematic Review
Chest Wall Hydatid Cysts: A Systematic Review
Abstract Introduction Given the rarity of chest wall hydatid disease, information on this condition is primarily drawn from case reports. Hence, this study systematically reviews t...
Effect Aerobic Exercise On Cardiorespiratory Fitness In Athlete
Effect Aerobic Exercise On Cardiorespiratory Fitness In Athlete
Background: Cardiorespiratory fitness or fitness is one of the endogenous factors that can affect athlete performance, this is because good cardiorespiratory fitness shows good end...
Influence of yoga practices and core exercises training on cardiorespiratory fitness of college females
Influence of yoga practices and core exercises training on cardiorespiratory fitness of college females
Background: Obesity is a major health issue in modern society. Regular physical exercise and healthy habits are some of the ways to get rid of it. In this study, researchers applie...
Estimation of Cardiorespiratory fitness using a using a chest mounted accelerometer
Estimation of Cardiorespiratory fitness using a using a chest mounted accelerometer
Abstract   Cardiorespiratory fitness expressed as maximal oxygen consumption (V̇O2 max) is a strong predictor of cardiovascular ...
Advancing Cardiorespiratory Physiotherapy Practice in a Developing Country: Surveying and Benchmarking
Advancing Cardiorespiratory Physiotherapy Practice in a Developing Country: Surveying and Benchmarking
Management of noncommunicable diseases requires the adoption of multidisciplinary interventions that targets the modification of risk factors. Cardiovascular and respiratory diseas...
Developing Total Force Fitness and Its Components to Achieve Optimal Military Performance in Iran
Developing Total Force Fitness and Its Components to Achieve Optimal Military Performance in Iran
Abstract Background Military personnel is the most valuable asset of the armed forces to carry out missions. The Iranian Armed Forces have not provided a comprehensive defi...