Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Numerical Simulation for Elasto-Plastic Contact of Novel Ti-(SiCf/Al3Ti)-Laminated Composite with Double-Layered SiC Fiber Reinforcements

View through CrossRef
An innovative, high-strength metal–intermetallic-laminate (MIL) composite Ti-(SiCf/Al3Ti), reinforced by double or even several SiC fiber rows, was fabricated. A high-efficiency, semi-analytical model with a numerical equivalent inclusion method (NEIM) was employed to investigate the deformation behaviors, microscopic strengthening, and failure mechanisms of the composite during elasto-plastic sphere–plane contact. The microstructure and interface features were characterized by scanning electron microscopy (SEM) and energy dispersive spectrometer (EDS). The contact model for the Ti-(SiCf/Al3Ti) composite was validated via quasi-static compressive indentation tests with a spherical indenter. A series of in-depth parametric studies were conducted to quantify the effect of the microstructure. The results indicate that the as-fabricated laminated composite has a well-organized microstructure and a higher volume fraction of fibers. The SiC fiber rows effectively enhance the strength and toughness of the composite. The optimal diameter of the SiC fibers is 32 μm when the horizontal center distance between the adjacent fibers is 2.5 times that of the fiber diameter. The hole defects occurring above the fibers would damage the material strength most compared with those occurring in other positions. The optimal quantity of the SiC fiber rows is four when the thickness of the SiCf/Al3Ti layer is 400 μm and the fiber diameter is 8 μm.
Title: Numerical Simulation for Elasto-Plastic Contact of Novel Ti-(SiCf/Al3Ti)-Laminated Composite with Double-Layered SiC Fiber Reinforcements
Description:
An innovative, high-strength metal–intermetallic-laminate (MIL) composite Ti-(SiCf/Al3Ti), reinforced by double or even several SiC fiber rows, was fabricated.
A high-efficiency, semi-analytical model with a numerical equivalent inclusion method (NEIM) was employed to investigate the deformation behaviors, microscopic strengthening, and failure mechanisms of the composite during elasto-plastic sphere–plane contact.
The microstructure and interface features were characterized by scanning electron microscopy (SEM) and energy dispersive spectrometer (EDS).
The contact model for the Ti-(SiCf/Al3Ti) composite was validated via quasi-static compressive indentation tests with a spherical indenter.
A series of in-depth parametric studies were conducted to quantify the effect of the microstructure.
The results indicate that the as-fabricated laminated composite has a well-organized microstructure and a higher volume fraction of fibers.
The SiC fiber rows effectively enhance the strength and toughness of the composite.
The optimal diameter of the SiC fibers is 32 μm when the horizontal center distance between the adjacent fibers is 2.
5 times that of the fiber diameter.
The hole defects occurring above the fibers would damage the material strength most compared with those occurring in other positions.
The optimal quantity of the SiC fiber rows is four when the thickness of the SiCf/Al3Ti layer is 400 μm and the fiber diameter is 8 μm.

Related Results

Effect of different kinds of SiC fibers on microwave absorption and mechanical properties of SiCf/SiC composites
Effect of different kinds of SiC fibers on microwave absorption and mechanical properties of SiCf/SiC composites
Abstract The SiC fibers are essential for designing microwave absorption and mechanical properties of multifunctional composites. In this study, SLF, KD-II and KD-S SiC fib...
Adjustments of the Rock-Eval® thermal analysis for Soil Organic and Inorganic Carbon (SOC and SIC) quantifications
Adjustments of the Rock-Eval® thermal analysis for Soil Organic and Inorganic Carbon (SOC and SIC) quantifications
Quantifying Soil Organic and Inorganic Carbon (SOC & SIC) separately in carbonate soils involves successive pretreatments and/or measurements to separate the two carbon forms. ...
ERROR ESTIMATION FOR A PIEZOELECTRIC CONTACT PROBLEM WITH WEAR AND LONG MEMORY
ERROR ESTIMATION FOR A PIEZOELECTRIC CONTACT PROBLEM WITH WEAR AND LONG MEMORY
We study a mathematical model for a quasistatic behavior of electro-viscoelastic materials. The problem is related to highly nonlinear and non-smooth phenomena like contact, fricti...
Application of laminated and cross-laminated timber in reconstruction and new construction
Application of laminated and cross-laminated timber in reconstruction and new construction
The article is devoted to the actual problem of restoration of construction objects of Ukraine destroyed as a result of military actions. The issue of manufacturing and effective a...
(Invited) 4H-SiC Ion Implanted Bipolar Junctions: Relevance of the 1950°C Temperature for Post Implantation Annealing
(Invited) 4H-SiC Ion Implanted Bipolar Junctions: Relevance of the 1950°C Temperature for Post Implantation Annealing
Ion implantation is a relevant technology for the fabrication of p-n interfaces in several SiC electronic devices; ion implanted source/drain and body regions in commercial 4H-SiC ...
Effect of In Situ Grown SiC Nanowires on the Pressureless Sintering of Heterophase Ceramics TaSi2-TaC-SiC
Effect of In Situ Grown SiC Nanowires on the Pressureless Sintering of Heterophase Ceramics TaSi2-TaC-SiC
To ascertain the influence of SiC nanowires on sintering kinetics of heterophase ceramics, two composite powders (TaSi2-TaC-SiC and TaSi2-TaC-SiC-SiCnanowire) are fabricated by mec...
A New Approach for Transition Metal Free Magnetic Sic: Defect Induced Magnetism After Self-ion Implantation
A New Approach for Transition Metal Free Magnetic Sic: Defect Induced Magnetism After Self-ion Implantation
SiC has become an attractive wide bandgap semiconductor due to its unique physical and electronic properties and is widely used in high temperature, high frequency, high power and ...

Back to Top