Javascript must be enabled to continue!
Changing Trends of Imaging in Angle Closure Evaluation
View through CrossRef
Primary angle closure glaucoma (PACG) is a significant cause of visual disability worldwide. It predominantly affects the Eastern and South Asian population of the world. Early detection of anatomically narrow angles is important, and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA). Gonioscopy has given way to modern day imaging technologies such as ultrasound biomicroscopy (UBM) and more recently, anterior segment optical coherence tomography (AS-OCT). Ultrasound biomicroscopy provides objective, high-resolution images of anterior segment anatomy, including the cornea, iris, anterior chamber, anterior chamber angle, and ciliary body. Optical coherence tomography (OCT) is a noncontact optical signal acquisition and processing device that provides magnified, high-resolution cross-sectional images of ocular tissues. Recent technological advances towards three-dimensional visualization broadened the scope of AS-OCT in ophthalmologic evaluation. Optical coherence tomography systems use low-coherence, near-infrared light to provide detailed images of anterior segment structures at resolutions exceeding that of UBM. This paper summarizes the clinical application of UBM and OCT for assessment of anterior segment in glaucoma.
Title: Changing Trends of Imaging in Angle Closure Evaluation
Description:
Primary angle closure glaucoma (PACG) is a significant cause of visual disability worldwide.
It predominantly affects the Eastern and South Asian population of the world.
Early detection of anatomically narrow angles is important, and the subsequent prevention of visual loss from PACG depends on an accurate assessment of the anterior chamber angle (ACA).
Gonioscopy has given way to modern day imaging technologies such as ultrasound biomicroscopy (UBM) and more recently, anterior segment optical coherence tomography (AS-OCT).
Ultrasound biomicroscopy provides objective, high-resolution images of anterior segment anatomy, including the cornea, iris, anterior chamber, anterior chamber angle, and ciliary body.
Optical coherence tomography (OCT) is a noncontact optical signal acquisition and processing device that provides magnified, high-resolution cross-sectional images of ocular tissues.
Recent technological advances towards three-dimensional visualization broadened the scope of AS-OCT in ophthalmologic evaluation.
Optical coherence tomography systems use low-coherence, near-infrared light to provide detailed images of anterior segment structures at resolutions exceeding that of UBM.
This paper summarizes the clinical application of UBM and OCT for assessment of anterior segment in glaucoma.
Related Results
ONE- VERSUS TWO-LAYER CLOSURE AT CESAREAN BIRTH
ONE- VERSUS TWO-LAYER CLOSURE AT CESAREAN BIRTH
Background: Cesarean delivery is one of the most commonly performed surgical procedures worldwide. The technique of uterine closure plays a significant role in postoperative recove...
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Correlation study of changes in visual acuity, pupil diameter, Kappa angle, and Alpha angle after phacoemulsification surgery combined with multifocal IOL implantation
Abstract
Purpose To study the changes and correlation of visual acuity, pupil size, kappa angle and Alpha angle after phacoemulsification combined with multifocal intraocul...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
The Effect of Clinical Knee Measurement in Children with Genu Varus
The Effect of Clinical Knee Measurement in Children with Genu Varus
Abstract
Introduction
Children with genu varus needs frequent assessment and follow up that may need several radiographies. This study investigates the effectiveness of the clinica...
Peritoneal Closure at Caesarean Section; A Comparative Cross-Sectional Study
Peritoneal Closure at Caesarean Section; A Comparative Cross-Sectional Study
Background: Cesarean section rates have been growing consistently on a worldwide scale. Peritoneal closure is important because it can help provide the best possible surgical resul...
Comparison of primary and delayed wound closure of dog-bite wounds
Comparison of primary and delayed wound closure of dog-bite wounds
SummaryBackground: Primary bite wound suturing in the emergency department remains controversial in some cases.Objective: We conducted a study to investigate the infection rate and...
Improving Sternal Closure Outcomes in Cardiac Surgery: Polyethylene Suture Tapes vs. Steel Wires
Improving Sternal Closure Outcomes in Cardiac Surgery: Polyethylene Suture Tapes vs. Steel Wires
Background: Steel wires are often inadequate for sternal closure for patients at high risk of sternal complications. This study compares a novel sternal closure system to conventio...