Method of Experts’ Quality Evaluation of the PET Images of the Patients
View through CrossRef
Purpose: To develop the method of experts’ quality evaluation of the PET images as an additional quality control method for accurate, comparable, and reproducible PET diagnostics results, and to conduct image quality evaluation in different PET departments used this method. Material and methods: 60 PET images (without CT) of the patients who underwent whole body PET/CT with 18F-FDG were collected from 12 PET/CT scanners in 9 PET departments. Experts’ quality evaluation was conducted with questioning of the experts. Each expert evaluated the image quality by five-point scale and filled out the special form which include three image quality criteria: image clarity, artefacts, and general image quality. There were 28 experts from 8 different PET departments who have work experience in radiology from 1 to 32 years. The results of experts’ quality evaluation of the PET images were examined for correlations with parameters of acquisition and reconstruction protocols, examination methods. The results were also examined for dependance of subjective factors such as work experience and work conditions of experts. The minimum required number of experts were defined. The results were analyzed used statistical methods. Results: The PET images obtained by 8 PET/CT scanners had mean quality value more than 4 points (good quality). PET/CT scanners, which had the lowest quality value, have the obsolete or unusual settings and reconstruction parameters. The correlations between experts’ quality evaluation of the PET images and acquisition parameters (acquisition time per bed, multiplication of injected activity and acquisition time per bed), and examination methods (injected activity and uptake time) were established. The results of experts’ quality evaluation of the PET images were dependent on work experience and work conditions of experts. Conclusion: The method of experts’ quality evaluation of the PET images of the patients based on the questioning of the experts working in PET was developed and demonstrated in the current study. The results showed this method has the potential to compare the PET images obtained by different acquisition and reconstruction protocols, and it can be applied during the optimization of examination method and for the determination of obsolete and unusual settings of PET/CT. Experts’ evaluation of the PET images should include the opinion of at least six experts with different work experience in PET from several PET departments.
Burnasyan Federal Medical Biophysical Center Of Federal Medical Biological Agency
Title: Method of Experts’ Quality Evaluation of the PET Images of the Patients
Description:
Purpose: To develop the method of experts’ quality evaluation of the PET images as an additional quality control method for accurate, comparable, and reproducible PET diagnostics results, and to conduct image quality evaluation in different PET departments used this method.
Material and methods: 60 PET images (without CT) of the patients who underwent whole body PET/CT with 18F-FDG were collected from 12 PET/CT scanners in 9 PET departments.
Experts’ quality evaluation was conducted with questioning of the experts.
Each expert evaluated the image quality by five-point scale and filled out the special form which include three image quality criteria: image clarity, artefacts, and general image quality.
There were 28 experts from 8 different PET departments who have work experience in radiology from 1 to 32 years.
The results of experts’ quality evaluation of the PET images were examined for correlations with parameters of acquisition and reconstruction protocols, examination methods.
The results were also examined for dependance of subjective factors such as work experience and work conditions of experts.
The minimum required number of experts were defined.
The results were analyzed used statistical methods.
Results: The PET images obtained by 8 PET/CT scanners had mean quality value more than 4 points (good quality).
PET/CT scanners, which had the lowest quality value, have the obsolete or unusual settings and reconstruction parameters.
The correlations between experts’ quality evaluation of the PET images and acquisition parameters (acquisition time per bed, multiplication of injected activity and acquisition time per bed), and examination methods (injected activity and uptake time) were established.
The results of experts’ quality evaluation of the PET images were dependent on work experience and work conditions of experts.
Conclusion: The method of experts’ quality evaluation of the PET images of the patients based on the questioning of the experts working in PET was developed and demonstrated in the current study.
The results showed this method has the potential to compare the PET images obtained by different acquisition and reconstruction protocols, and it can be applied during the optimization of examination method and for the determination of obsolete and unusual settings of PET/CT.
Experts’ evaluation of the PET images should include the opinion of at least six experts with different work experience in PET from several PET departments.
Related Results
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
A enfermagem é o pilar da assistência pois está na linha de frente do cuidado holístico, todavia esta é estigmatizada e desvalorizada, assim como não possui reconhecimento consider...
Comparative study of total-body PET and PET/MR in the diagnosis of liver metastases
Comparative study of total-body PET and PET/MR in the diagnosis of liver metastases
ObjectiveTo compare the diagnostic differences between total-body PET/CT (positron emission tomography/computed tomography) and PET/MR (positron emission tomography/magnetic resona...
Forced diuresis and dual-phase 18F-fluorodeoxyglucose-PET/CT scan for restaging of urinary bladder cancers
Forced diuresis and dual-phase 18F-fluorodeoxyglucose-PET/CT scan for restaging of urinary bladder cancers
Abstract
Context: The results of 18 F-fluorodeoxyglucose (FDG)-PET imaging carried out with the current standard techniques for assessment of urinary tract cancers have...
Evaluation of pulmonary nodules and lung cancer with one‐inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT
Evaluation of pulmonary nodules and lung cancer with one‐inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT
SummaryDedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d‐PET) have become standard imaging instruments in many malignancies. Hybrid gamma ...
Comparison of 18F-FDG-PET and 18F-FDG-PET/CT for the diagnostic performance in thyroid nodules with indeterminate cytology
Comparison of 18F-FDG-PET and 18F-FDG-PET/CT for the diagnostic performance in thyroid nodules with indeterminate cytology
Abstract
Backgrounds:
We performed a meta-analysis to compare 18F-FDG-PET and 18F-FDG-PET/CT for the diagnostic performance in thyroid nodules wi...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract
The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Mechanical Properties of Recycled Polyethylene Terephthalate/ Polycarbonate/ Methylene Diphenyl Diisocyanate (r-PET/PC/MDI) Composite
Mechanical Properties of Recycled Polyethylene Terephthalate/ Polycarbonate/ Methylene Diphenyl Diisocyanate (r-PET/PC/MDI) Composite
The present study aimed to investigate the mechanical properties of recycled Polyethylene Terephthalate (r-PET) and Polycarbonate (PC) composites, with the incorporation of Methyle...
The Role of PET/TC in the Full Range of Monoclonal Gammopathies
The Role of PET/TC in the Full Range of Monoclonal Gammopathies
Abstract
Positron emission tomography (PET) with 18fluorine-fluoro-deoxyglucose (FDG) integrated with computed tomography (PET/CT) is a functional imaging technique ...