Javascript must be enabled to continue!
Effects of Flow Oscillations in the Mainstream on Film Cooling
View through CrossRef
The objective of this study is to investigate the effects of oscillations in the main flow and the coolant jets on film cooling at various frequencies (0 to 2144 Hz) at low and high average blowing ratios. Numerical simulations are performed using LES Smagorinsky–Lilly turbulence model for calculation of the adiabatic film cooling effectiveness and using the DES Realizable k-epsilon turbulence model for obtaining the Stanton number ratios (St/Sto). Additionally, multi-frequency inlet velocities are applied to the main and coolant flows to explore the effects of multi-frequency unsteady flows and the results are compared to those at single frequencies. The results show that at a low average blowing ratio (M = 0.5) if the oscillation frequency is increased from 0 to 180 Hz, the effectiveness decreases and the Stanton number ratio increases. However, when the frequency goes from 180 to 268 Hz, the effectiveness sharply increases and the Stanton number ratio increases slightly. If the frequency changes from 268 to 1072 Hz, the film cooling effectiveness decreases and the Stanton number ratio increases slightly. If the frequency goes from 1072 to 2144 Hz, the film cooling effectiveness climbs up and the Stanton number ratio decreases. The results show that at high average blowing ratio (M = 1.0) the trends of the film cooling effectiveness are similar to those at low blowing ratio (M = 0.5) except from 0 to 90 Hz. If the frequency goes from 0 to 90 Hz at M = 1.0, the film cooling effectiveness increases and the Stanton number ratio decreases. It can be said that it is important to include the effects of oscillating flows when designing film cooling systems for a gas turbine.
Title: Effects of Flow Oscillations in the Mainstream on Film Cooling
Description:
The objective of this study is to investigate the effects of oscillations in the main flow and the coolant jets on film cooling at various frequencies (0 to 2144 Hz) at low and high average blowing ratios.
Numerical simulations are performed using LES Smagorinsky–Lilly turbulence model for calculation of the adiabatic film cooling effectiveness and using the DES Realizable k-epsilon turbulence model for obtaining the Stanton number ratios (St/Sto).
Additionally, multi-frequency inlet velocities are applied to the main and coolant flows to explore the effects of multi-frequency unsteady flows and the results are compared to those at single frequencies.
The results show that at a low average blowing ratio (M = 0.
5) if the oscillation frequency is increased from 0 to 180 Hz, the effectiveness decreases and the Stanton number ratio increases.
However, when the frequency goes from 180 to 268 Hz, the effectiveness sharply increases and the Stanton number ratio increases slightly.
If the frequency changes from 268 to 1072 Hz, the film cooling effectiveness decreases and the Stanton number ratio increases slightly.
If the frequency goes from 1072 to 2144 Hz, the film cooling effectiveness climbs up and the Stanton number ratio decreases.
The results show that at high average blowing ratio (M = 1.
0) the trends of the film cooling effectiveness are similar to those at low blowing ratio (M = 0.
5) except from 0 to 90 Hz.
If the frequency goes from 0 to 90 Hz at M = 1.
0, the film cooling effectiveness increases and the Stanton number ratio decreases.
It can be said that it is important to include the effects of oscillating flows when designing film cooling systems for a gas turbine.
Related Results
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
It was always based on a teenage love story between the two kids. One is a sniffer and one is not. It was designed for Central Australia because we do write these kids off there. N...
Effects of Oscillations in the Mainstream on Film Cooling at Various Blowing Ratios
Effects of Oscillations in the Mainstream on Film Cooling at Various Blowing Ratios
The objective of this study is to understand the effects of flow oscillations in the mainstream and film cooling jets on film cooling at various blowing ratios (0.5, 0.78, 1.0 and ...
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Large Eddy Simulations on Fan Shaped Film Cooling Hole With Various Inlet Turbulence Generation Methods
Abstract
Large eddy simulations on well-known 7-7-7 fan shaped cooling hole have been carried out. Film cooling methods are generally applied to high pressure turbin...
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Abstract
Film cooling technology is widely used in gas turbines. Improvement of gas turbine thermal efficiency, specific power and specific thrust can be achieved by...
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Effect of Hole Diameter on Nozzle Endwall Film Cooling and Associated Phantom Cooling
Effect of Hole Diameter on Nozzle Endwall Film Cooling and Associated Phantom Cooling
Flow fields near the turbine nozzle endwall are highly complex due to the passage vortices and endwall cross flows. Consequently, it is challenging to provide proper cooling to the...
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Abstract
Based on the infrared temperature measurement technology, in this paper, the effect of the purge flow from the upstream slot on the film cooling performance...
Application of a CFD-Based Film Cooling Model to a Gas Turbine Vane Cascade With Cylindrical and Shaped Hole Endwall Film Cooling
Application of a CFD-Based Film Cooling Model to a Gas Turbine Vane Cascade With Cylindrical and Shaped Hole Endwall Film Cooling
This paper presents the application of a CFD-based film cooling model to a gas turbine vane cascade test rig. The experimental investigations feature aerodynamic and endwall film c...

