Comparison of sirolimus‐eluting stent, paclitaxel‐eluting stent, and bare metal stent in the treatment of long coronary lesions

View through CrossRef
AbstractObjective: This study compared the efficacy of the sirolimus‐eluting stent (SES), the paclitaxel‐eluting stent (PES), and the bare metal stent (BMS) for long coronary lesions. Background: The outcome of drug‐eluting stent (DES) implantation in long coronary lesions remains unclear. Methods: The study involved 527 patients with de novo long coronary lesions (≥24 mm), which were treated with long (≥28 mm) SESs (223 lesions), PESs (194 lesions), or BMSs (201 lesions). Results: Lesions in the SES (36.0 ± 14.9 mm, P < 0.001) and PES (36.3 ± 14.5 mm, P < 0.001) groups were longer than those in the BMS group (32.0 ± 12.3 mm), meaning the two DES groups had longer stented segments than did the BMS group. Six‐month angiographic follow‐up showed the SES (9.3%, P < 0.001) and PES (21.3%, P < 0.001) groups had lower in‐segment restenosis rates than that of the BMS group (42.5%). The rate of major adverse cardiac events (MACE) including death, myocardial infarction, and target lesion revascularization at 9 months was higher in the BMS group (26.6%) than that in the SES (13.0%, P < 0.001) and PES (15.7%, P < 0.001) groups. Posthoc analysis of the two DES groups showed that the in‐segment restenosis rate was lower for the SES than that for the PES group (P = 0.002), while the MACE rate was similar. Conclusions: The use of DESs for long coronary lesions appears to be safe and more effective than the use of BMSs in terms of restenosis and adverse clinical events. SES use was associated with lower late luminal loss and a lower angiographic restenosis rate compared with PES use. © 2006 Wiley‐Liss, Inc.
Title: Comparison of sirolimus‐eluting stent, paclitaxel‐eluting stent, and bare metal stent in the treatment of long coronary lesions
Description:
AbstractObjective: This study compared the efficacy of the sirolimus‐eluting stent (SES), the paclitaxel‐eluting stent (PES), and the bare metal stent (BMS) for long coronary lesions.
Background: The outcome of drug‐eluting stent (DES) implantation in long coronary lesions remains unclear.
Methods: The study involved 527 patients with de novo long coronary lesions (≥24 mm), which were treated with long (≥28 mm) SESs (223 lesions), PESs (194 lesions), or BMSs (201 lesions).
Results: Lesions in the SES (36.
0 ± 14.
9 mm, P < 0.
001) and PES (36.
3 ± 14.
5 mm, P < 0.
001) groups were longer than those in the BMS group (32.
0 ± 12.
3 mm), meaning the two DES groups had longer stented segments than did the BMS group.
Six‐month angiographic follow‐up showed the SES (9.
3%, P < 0.
001) and PES (21.
3%, P < 0.
001) groups had lower in‐segment restenosis rates than that of the BMS group (42.
5%).
The rate of major adverse cardiac events (MACE) including death, myocardial infarction, and target lesion revascularization at 9 months was higher in the BMS group (26.
6%) than that in the SES (13.
0%, P < 0.
001) and PES (15.
7%, P < 0.
001) groups.
Posthoc analysis of the two DES groups showed that the in‐segment restenosis rate was lower for the SES than that for the PES group (P = 0.
002), while the MACE rate was similar.
Conclusions: The use of DESs for long coronary lesions appears to be safe and more effective than the use of BMSs in terms of restenosis and adverse clinical events.
SES use was associated with lower late luminal loss and a lower angiographic restenosis rate compared with PES use.
© 2006 Wiley‐Liss, Inc.

Related Results

Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Crush Stenting With Paclitaxel-Eluting or Sirolimus-Eluting Stents for the Treatment of Coronary Bifurcation Lesions
Two hundred forty-six patients with 252 bifurcation lesions were enrolled into a prospective, nonrandomized study to use paclitaxel-eluting or sirolimus-eluting stent for crush ste...
Sirolimus PK trial: A pharmacokinetic study of the sirolimus‐eluting Bx Velocity stent in patients with de novo coronary lesions
Sirolimus PK trial: A pharmacokinetic study of the sirolimus‐eluting Bx Velocity stent in patients with de novo coronary lesions
AbstractThis study was conducted to assess the systemic drug release and distribution of sirolimus‐eluting stents. Early results with sirolimus‐eluting stents have demonstrated a f...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Effectiveness and safety of the sirolimus‐eluting stents coated with bioabsorbable polymer coating in human coronary arteries
Effectiveness and safety of the sirolimus‐eluting stents coated with bioabsorbable polymer coating in human coronary arteries
AbstractBackground: Although the sirolimus‐eluting stent (CYPHER®, Cordis, USA) has shown a dramatic reduction of restenosis, there are still some concerns about its efficacy and s...
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Introduction: The most prevalent complication of cardiac intervention is restenosis. After the BMS period, drug-eluting stents (DES) are the most suitable choice for stenosis treat...

Back to Top