Javascript must be enabled to continue!
To evaluate the functional and anatomical outcomes for autologous retinal autograft with Finesse™ Flex Loop for failed macular holes
View through CrossRef
Purpose:
To evaluate the functional and anatomical outcomes for autologous retinal autograft with Finesse™ Flex Loop for failed macular holes.
Methods:
This is a retrospective study analyzing medical records of consecutive patients with refractory macular hole (at least 1 prior surgery) and eyes with retinal detachment with coexisting macular holes (MH). Optical coherence tomography (OCT) of the macula was performed before and after surgery. The primary study outcome evaluated were the functional and anatomic macular hole closure, and secondary outcomes were improvement in visual acuity and restoration of the outer retinal bands, external limiting membrane, and ellipsoid zone in eyes with acquisition of autologous retinal transplant using Finesse Loop.
Results:
The study included eight eyes of eight patients; retinal autograft was performed in six (75.0%) and autologous retinal transplantation (ART) with rhegmatogenous retinal detachment (RRD) was performed in two (25.0%) eyes. The average MH basal diameter in the study was 1310.88 ± 138.63 µm. The successful hole closure rate was observed to be 75% (6 eyes) and 100% retinal reattachment was observed in ART with RRD. Statistically significant (P = 0.001) improvement was noted for preop and postop visual acuity gain for ART acquisition and postop macular hole closure. The restoration of the external limiting membrane (ELM) and ellipsoid zone (EZ) was observed in 37.5% (3 eyes) of patients.
Conclusion:
Finesse™ Flex Loop can be used to harvest retinal tissue and it provides good anatomical and functional outcomes for failed macular hole.
Title: To evaluate the functional and anatomical outcomes for autologous retinal autograft with Finesse™ Flex Loop for failed macular holes
Description:
Purpose:
To evaluate the functional and anatomical outcomes for autologous retinal autograft with Finesse™ Flex Loop for failed macular holes.
Methods:
This is a retrospective study analyzing medical records of consecutive patients with refractory macular hole (at least 1 prior surgery) and eyes with retinal detachment with coexisting macular holes (MH).
Optical coherence tomography (OCT) of the macula was performed before and after surgery.
The primary study outcome evaluated were the functional and anatomic macular hole closure, and secondary outcomes were improvement in visual acuity and restoration of the outer retinal bands, external limiting membrane, and ellipsoid zone in eyes with acquisition of autologous retinal transplant using Finesse Loop.
Results:
The study included eight eyes of eight patients; retinal autograft was performed in six (75.
0%) and autologous retinal transplantation (ART) with rhegmatogenous retinal detachment (RRD) was performed in two (25.
0%) eyes.
The average MH basal diameter in the study was 1310.
88 ± 138.
63 µm.
The successful hole closure rate was observed to be 75% (6 eyes) and 100% retinal reattachment was observed in ART with RRD.
Statistically significant (P = 0.
001) improvement was noted for preop and postop visual acuity gain for ART acquisition and postop macular hole closure.
The restoration of the external limiting membrane (ELM) and ellipsoid zone (EZ) was observed in 37.
5% (3 eyes) of patients.
Conclusion:
Finesse™ Flex Loop can be used to harvest retinal tissue and it provides good anatomical and functional outcomes for failed macular hole.
Related Results
Internal limiting membrane peel with or without finesse flex loop assistance
Internal limiting membrane peel with or without finesse flex loop assistance
Background: Internal Limiting Membrane (ILM) peeling, currently, due to more successful hole closure rate and prevention of postoperative reopening, has been accepted globally but ...
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Long-term Structural and Functional Outcomes after Autologous Retinal Transplant Surgery for Complex Macular Hole
Long-term Structural and Functional Outcomes after Autologous Retinal Transplant Surgery for Complex Macular Hole
Abstract
BACKGROUND
Vitrectomy and internal limiting membrane peeling has been the Gold Standard for macular hole treatment since the 90s with high closure rates for idiop...
Anatomical and functional correlates of cystic macular edema in retinitis pigmentosa
Anatomical and functional correlates of cystic macular edema in retinitis pigmentosa
Cystoid macular edema (CME) is a major cause of central visual deterioration in retinitis pigmentosa. The exact reason for CME and its prognostic significance in this patient popul...
Retinal oximetry in patients with ischaemic retinal diseases
Retinal oximetry in patients with ischaemic retinal diseases
AbstractThe retinal oximeter is a new tool for non‐invasive measurement of retinal oxygen saturation in humans. Several studies have investigated the associations between retinal o...
Retinal displacement after surgery for idiopathic macular hole
Retinal displacement after surgery for idiopathic macular hole
AIM: To review and summarize the mechanism hypothesis, influencing factors and possible consequences of macular retinal displacement after idiopathic macular hole (IMH) surgery.
ME...
Implementation of M-Flex Based Moodle in Pancasila Course: An Initial Evaluation on Student’s View
Implementation of M-Flex Based Moodle in Pancasila Course: An Initial Evaluation on Student’s View
<p><strong>Abstract </strong></p><p>M-Flex is the approach used by utilizing various interesting and quality online learning maneuvers. Moodle-based M...
Telomere Length of Hematopoietic Cells in Long-Term Post-Autograft Survivors: No Evidence of Accelerated Replicative Cell Senescence Despite the Persistent Reduction of Both Committed and Immature Progenitor Cell Compartments.
Telomere Length of Hematopoietic Cells in Long-Term Post-Autograft Survivors: No Evidence of Accelerated Replicative Cell Senescence Despite the Persistent Reduction of Both Committed and Immature Progenitor Cell Compartments.
Abstract