Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Flexural sensitivity of high resonant atomic force microscopy cantilever based on optical lever detection

View through CrossRef
Flexural sensitivity is a key parameter of atomic force microscopy. In order to improve the dynamic atomic force microscopy’s flexural sensitivity, a scanning method that drives the atomic force microscopy cantilever vibrating at its high resonant frequency is utilized. In this article, the operation principle of the high resonant atomic force microscopy is introduced and the factors that affect the sensitivity in the measurement of the displacement of the amplitude based on optical lever detection method are analyzed, and the flexural sensitivities of the cantilever vibrating at different resonant frequencies are compared theoretically and measured experimentally. The experimental results indicate that the flexural resolution of atomic force microscopy operated on the fundamental mode and the second mode is 0.30 and 0.13 nm, respectively. Both the theoretical and experimental results demonstrate that the flexural sensitivity of the high resonant cantilever is better than that of the fundamental mode cantilever. It is an effective method to improve the sensitivity of dynamic atomic force microscopy cantilever by working at higher resonant frequency.
Title: Flexural sensitivity of high resonant atomic force microscopy cantilever based on optical lever detection
Description:
Flexural sensitivity is a key parameter of atomic force microscopy.
In order to improve the dynamic atomic force microscopy’s flexural sensitivity, a scanning method that drives the atomic force microscopy cantilever vibrating at its high resonant frequency is utilized.
In this article, the operation principle of the high resonant atomic force microscopy is introduced and the factors that affect the sensitivity in the measurement of the displacement of the amplitude based on optical lever detection method are analyzed, and the flexural sensitivities of the cantilever vibrating at different resonant frequencies are compared theoretically and measured experimentally.
The experimental results indicate that the flexural resolution of atomic force microscopy operated on the fundamental mode and the second mode is 0.
30 and 0.
13 nm, respectively.
Both the theoretical and experimental results demonstrate that the flexural sensitivity of the high resonant cantilever is better than that of the fundamental mode cantilever.
It is an effective method to improve the sensitivity of dynamic atomic force microscopy cantilever by working at higher resonant frequency.

Related Results

Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding t...
Renormalization, resonance bifurcation, and phase contrast in dynamic atomic force microscopy
Renormalization, resonance bifurcation, and phase contrast in dynamic atomic force microscopy
Renormalization of the model describing dynamic atomic force microscopy is shown to provide a simple and robust interpretation of cantilever dynamics as a single spring and mass wi...
Highly-efficient optical storage of two orthogonal polarization modes in a cold atom ensemble
Highly-efficient optical storage of two orthogonal polarization modes in a cold atom ensemble
Optical quantum memory plays an important role in scaling-up linear optical quantum computations and longdistance quantum communication. For effectively realizing such tasks, a lon...
Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with h...
Resonance Based Force Measurement: Prelude to High-Resolution Anemometry for Liquid Metal Flows
Resonance Based Force Measurement: Prelude to High-Resolution Anemometry for Liquid Metal Flows
Abstract This paper describes the first phase of a two-part project designed to develop a new anemometry method for use in high temperature liquid metal flows. The d...
Generalized Heterodyne Configurations for Photo-induced Force Microscopy
Generalized Heterodyne Configurations for Photo-induced Force Microscopy
Infrared chemical microscopy through mechanical probing of light-matter interactions by atomic force microscopy (AFM) bypasses the diffraction limit. One increasingly popular techn...
Erratum
Erratum
Erratum: “Separation of Resonant and Non-Resonant Components-Part I: Sound Reduction Index” Jeffrey Mahn There was an error...
Measurement of Mechanical Properties of Cantilever Shaped Materials
Measurement of Mechanical Properties of Cantilever Shaped Materials
Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM) due to their extremely high sensitivity in measuring surface forces. The versatility of th...

Back to Top