Javascript must be enabled to continue!
Flexural sensitivity of high resonant atomic force microscopy cantilever based on optical lever detection
View through CrossRef
Flexural sensitivity is a key parameter of atomic force microscopy. In order to improve the dynamic atomic force microscopy’s flexural sensitivity, a scanning method that drives the atomic force microscopy cantilever vibrating at its high resonant frequency is utilized. In this article, the operation principle of the high resonant atomic force microscopy is introduced and the factors that affect the sensitivity in the measurement of the displacement of the amplitude based on optical lever detection method are analyzed, and the flexural sensitivities of the cantilever vibrating at different resonant frequencies are compared theoretically and measured experimentally. The experimental results indicate that the flexural resolution of atomic force microscopy operated on the fundamental mode and the second mode is 0.30 and 0.13 nm, respectively. Both the theoretical and experimental results demonstrate that the flexural sensitivity of the high resonant cantilever is better than that of the fundamental mode cantilever. It is an effective method to improve the sensitivity of dynamic atomic force microscopy cantilever by working at higher resonant frequency.
Title: Flexural sensitivity of high resonant atomic force microscopy cantilever based on optical lever detection
Description:
Flexural sensitivity is a key parameter of atomic force microscopy.
In order to improve the dynamic atomic force microscopy’s flexural sensitivity, a scanning method that drives the atomic force microscopy cantilever vibrating at its high resonant frequency is utilized.
In this article, the operation principle of the high resonant atomic force microscopy is introduced and the factors that affect the sensitivity in the measurement of the displacement of the amplitude based on optical lever detection method are analyzed, and the flexural sensitivities of the cantilever vibrating at different resonant frequencies are compared theoretically and measured experimentally.
The experimental results indicate that the flexural resolution of atomic force microscopy operated on the fundamental mode and the second mode is 0.
30 and 0.
13 nm, respectively.
Both the theoretical and experimental results demonstrate that the flexural sensitivity of the high resonant cantilever is better than that of the fundamental mode cantilever.
It is an effective method to improve the sensitivity of dynamic atomic force microscopy cantilever by working at higher resonant frequency.
Related Results
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
Bifurcation, chaos, and scan instability in dynamic atomic force microscopy
The dynamical motion at any point on the cantilever of an atomic force microscope can be expressed quite generally as a superposition of simple harmonic oscillators corresponding t...
Renormalization, resonance bifurcation, and phase contrast in dynamic atomic force microscopy
Renormalization, resonance bifurcation, and phase contrast in dynamic atomic force microscopy
Renormalization of the model describing dynamic atomic force microscopy is shown to provide a simple and robust interpretation of cantilever dynamics as a single spring and mass wi...
Highly-efficient optical storage of two orthogonal polarization modes in a cold atom ensemble
Highly-efficient optical storage of two orthogonal polarization modes in a cold atom ensemble
Optical quantum memory plays an important role in scaling-up linear optical quantum computations and longdistance quantum communication. For effectively realizing such tasks, a lon...
Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND
To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with high prec...
Measurement of Mechanical Properties of Cantilever Shaped Materials
Measurement of Mechanical Properties of Cantilever Shaped Materials
Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM) due to their extremely high sensitivity in measuring surface forces. The versatility of th...
Nanoscale subsurface imaging via resonant difference-frequency atomic force ultrasonic microscopy
Nanoscale subsurface imaging via resonant difference-frequency atomic force ultrasonic microscopy
A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. It employs an ultrasonic wave launc...
Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials
Effect Of Methyl Formate-Methyl Acetate Treatment On Flexural Strength Between Denture Base And Self-Cured Hard Reline Materials
The purpose of this study was to evaluate the effect of methyl formate-methyl acetate (MF-MA) surface treatment on the flexural strength between denture base and hard reline materi...

