Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of Performance and Longevity of Ti-Cu Dry Electrodes: Degradation Analysis Using Anodic Stripping Voltammetry

View through CrossRef
This study aimed to investigate the degradation of dry biopotential electrodes using the anodic stripping voltammetry (ASV) technique. The electrodes were based on Ti-Cu thin films deposited on different polymeric substrates (polyurethane, polylactic acid, and cellulose) by Direct Current (DC) magnetron sputtering. TiCu0.34 thin films (chemical composition of 25.4 at.% Cu and 74.6 at.% Ti) were prepared by sputtering a composite Ti target. For comparison purposes, a Cu-pure thin film was prepared under the same conditions and used as a reference. Both films exhibited dense microstructures with differences in surface topography and crystalline structure. The degradation process involved immersing TiCu0.34 and Cu-pure thin films in artificial sweat (prepared following the ISO standard 3160-2) for different durations (1 h, 4 h, 24 h, 168 h, and 240 h). ASV was the technique selected to quantify the amount of Cu(II) released by the electrodes immersed in the sweat solution. The optimal analysis conditions were set for 120 s and −1.0 V for time deposition and potential deposition, respectively, with a quantification limit of 0.050 ppm and a detection limit of 0.016 ppm. The results showed that TiCu0.34 electrodes on polyurethane substrates were significantly more reliable over time compared to Cu-pure electrodes. After 240 h of immersion, the TiCu0.34 electrodes released a maximum of 0.06 ppm Cu, while Cu-pure electrodes released 16 ppm. The results showed the significant impact of the substrate on the electrode’s longevity, with cellulose bases performing poorly. TiCu0.34 thin films on cellulose released 1.15 µg/cm2 of copper after 240 h, compared to 1.12 mg/cm2 from Cu-pure films deposited on the same substrate. Optical microscopy revealed that electrodes based on polylactic acid substrates were more prone to corrosion over time, whereas TiCu thin-film metallic glass-like structures on PU substrates showed extended lifespan. This study underscored the importance of assessing the degradation of dry biopotential electrodes for e-health applications, contributing to developing more durable and reliable sensing devices. While the study simulated real-world conditions using artificial sweat, it did not involve in vivo measurements.
Title: Evaluation of Performance and Longevity of Ti-Cu Dry Electrodes: Degradation Analysis Using Anodic Stripping Voltammetry
Description:
This study aimed to investigate the degradation of dry biopotential electrodes using the anodic stripping voltammetry (ASV) technique.
The electrodes were based on Ti-Cu thin films deposited on different polymeric substrates (polyurethane, polylactic acid, and cellulose) by Direct Current (DC) magnetron sputtering.
TiCu0.
34 thin films (chemical composition of 25.
4 at.
% Cu and 74.
6 at.
% Ti) were prepared by sputtering a composite Ti target.
For comparison purposes, a Cu-pure thin film was prepared under the same conditions and used as a reference.
Both films exhibited dense microstructures with differences in surface topography and crystalline structure.
The degradation process involved immersing TiCu0.
34 and Cu-pure thin films in artificial sweat (prepared following the ISO standard 3160-2) for different durations (1 h, 4 h, 24 h, 168 h, and 240 h).
ASV was the technique selected to quantify the amount of Cu(II) released by the electrodes immersed in the sweat solution.
The optimal analysis conditions were set for 120 s and −1.
0 V for time deposition and potential deposition, respectively, with a quantification limit of 0.
050 ppm and a detection limit of 0.
016 ppm.
The results showed that TiCu0.
34 electrodes on polyurethane substrates were significantly more reliable over time compared to Cu-pure electrodes.
After 240 h of immersion, the TiCu0.
34 electrodes released a maximum of 0.
06 ppm Cu, while Cu-pure electrodes released 16 ppm.
The results showed the significant impact of the substrate on the electrode’s longevity, with cellulose bases performing poorly.
TiCu0.
34 thin films on cellulose released 1.
15 µg/cm2 of copper after 240 h, compared to 1.
12 mg/cm2 from Cu-pure films deposited on the same substrate.
Optical microscopy revealed that electrodes based on polylactic acid substrates were more prone to corrosion over time, whereas TiCu thin-film metallic glass-like structures on PU substrates showed extended lifespan.
This study underscored the importance of assessing the degradation of dry biopotential electrodes for e-health applications, contributing to developing more durable and reliable sensing devices.
While the study simulated real-world conditions using artificial sweat, it did not involve in vivo measurements.

Related Results

Preparation of Silver-Based Mercury Film Electrodes for Anodic Stripping Voltammetry
Preparation of Silver-Based Mercury Film Electrodes for Anodic Stripping Voltammetry
The aim of this study was to develop an electrochemical method for reproducible preparation and evaluation of silver-based mercury film electrodes (SBMFE) for applications such as ...
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Boosting Oxygen Electrode Performance via a Redox-Treatment
Boosting Oxygen Electrode Performance via a Redox-Treatment
Introduction The transition to a sustainable energy system complying with climate policy targets is a huge societal challenge. “Hard to electri...
Effects of binder and solvent on cathode manufacturing for Li-ion batteries
Effects of binder and solvent on cathode manufacturing for Li-ion batteries
Lithium-ion batteries (LIBs) have played a significant role in consumer electronics and electric vehicles. The major focus of research in Li-ion batteries has been to maximize perf...
The synergy between deformation and anodic dissolution of an austenitic stainless steel in acidic chloride solution
The synergy between deformation and anodic dissolution of an austenitic stainless steel in acidic chloride solution
AbstractIn corrosion medium, metals can deform under tensile stress and form a new active surface with the anodic dissolution of the metals being accelerated. At the same time, the...
To evaluate the outcome of varicose vein surgery with and without venous stripping
To evaluate the outcome of varicose vein surgery with and without venous stripping
Aim: The aim of this study to evaluate the outcome of varicose vein surgery with and without venous stripping.Material and methods: This research covered 100 varicose vein operatio...
Recent Observations in Surface Electromyography Recording of Triceps Brachii Muscle in Patients and Athletes
Recent Observations in Surface Electromyography Recording of Triceps Brachii Muscle in Patients and Athletes
Objective: To observe and analyse the literature on the use of surface electromyography electrodes, including the shape, size, and metal composition of the electrodes used, the int...
Amalgam Electrodes for Electroanalysis
Amalgam Electrodes for Electroanalysis
AbstractLiquid mercury is a unique material for the indicator electrode in voltammetry. One reason for this is the high overvoltage for hydrogen formation, thus extending the actua...

Back to Top