Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Validation of Vacuum Consistency of The Internal Evacuated Blood Collection Tube (BCT)

View through CrossRef
Evacuated blood collection tube (BCT) or also known as Vacutainer® is a device which accumulate negative pressure as a function of vacuum to collect blood as a specimen for pharmaceutical analysis. Nevertheless, BCT consist of three (3) components which is transparent tube, rubber stopper, and hemogard closure. Study of vacuum on BCT has become interest in many researchers about its consistency due to effect by its surrounding condition. In this research, impact of storage temperature will be studied to identify the effect of vacuum content within BCT, also to investigate the problem and seek proper (surrounding) placement for these BCT. At the same time, it should develop with a new benchmark vacuum volume (negative pressure) inside BCT aiming to obtain the standardise figure. This BCT should be placed under temperature condition between 4°C to 25°C as suggested by BD-Vacutainer® company and under certified humidity condition are ranged between 40% to 60%. It is to ensure the pharmaceutical device which is sterile and consist of shelf life does not deplete its properties drastically and sustain its life span as recommended based on technical data sheet. Thus, the amount of negative pressure in BCT presentively indicate as a shelf life.
Title: Validation of Vacuum Consistency of The Internal Evacuated Blood Collection Tube (BCT)
Description:
Evacuated blood collection tube (BCT) or also known as Vacutainer® is a device which accumulate negative pressure as a function of vacuum to collect blood as a specimen for pharmaceutical analysis.
Nevertheless, BCT consist of three (3) components which is transparent tube, rubber stopper, and hemogard closure.
Study of vacuum on BCT has become interest in many researchers about its consistency due to effect by its surrounding condition.
In this research, impact of storage temperature will be studied to identify the effect of vacuum content within BCT, also to investigate the problem and seek proper (surrounding) placement for these BCT.
At the same time, it should develop with a new benchmark vacuum volume (negative pressure) inside BCT aiming to obtain the standardise figure.
This BCT should be placed under temperature condition between 4°C to 25°C as suggested by BD-Vacutainer® company and under certified humidity condition are ranged between 40% to 60%.
It is to ensure the pharmaceutical device which is sterile and consist of shelf life does not deplete its properties drastically and sustain its life span as recommended based on technical data sheet.
Thus, the amount of negative pressure in BCT presentively indicate as a shelf life.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Validation in Doctoral Education: Exploring PhD Students’ Perceptions of Belonging to Scaffold Doctoral Identity Work
Aim/Purpose: The aim of this article is to make a case of the role of validation in doctoral education. The purpose is to detail findings from three studies which explore PhD stude...
Groundwater Potential Mapping Using Remote Sensing and GIS-Based Machine Learning Techniques
Groundwater Potential Mapping Using Remote Sensing and GIS-Based Machine Learning Techniques
Adequate groundwater development for the rural population is essential because groundwater is an important source of drinking water and agricultural water. In this study, ensemble ...
Lead‐Free Pyroelectric Materials for Thermal Energy Harvesting: A Comparative Study
Lead‐Free Pyroelectric Materials for Thermal Energy Harvesting: A Comparative Study
AbstractThe thermal energy harvesting potential of different pyroelectric materials including Sr0.5Ba0.5Nb2O5(SBN), [Bi0.48Na0.4032K0.0768] Sr0.04(Ti0.975Nb0.025)O3(BNT‐Nb), Ba0.85...
Expectations, Affect Change, and Military Performance in the Army Recruit
Expectations, Affect Change, and Military Performance in the Army Recruit
Previous study at Fort Dix of the distressful affective response of Army recruits to basic combat training (BCT) was extended to Fort Ord. Several features of the inverted-U BCT di...
Tube Shunt Related Complications in Pediatrics
Tube Shunt Related Complications in Pediatrics
Although medical therapy is usually an excellent therapeutic option in the adult population, in children it is often ineffective or associated with an undesirable risk:benefit rati...
Factors Affecting the Adoption of Blockchain Technology in the Complex Industrial Systems: Data Modeling
Factors Affecting the Adoption of Blockchain Technology in the Complex Industrial Systems: Data Modeling
Nowadays, Blockchain Technology (BCT) is contributing toward addressing the challenges of complex industrial systems (CISs). The BCT reduces the complexity of cash data storage as ...

Back to Top