Javascript must be enabled to continue!
Novel approach to constructing laser ionization elemental time-of-flight mass spectrometer
View through CrossRef
The main advantages of laser sampling are associated with following features: sample preparations as well as consumables are not needed, low risk of sample contamination, good spatial resolution. In mass spectrometry, high laser irradiance can be used for both ablation and ionization processes. The method is especially profitable in time-of-flight mass spectrometry. A new principle of constructing laser ionization time-of-flight mass spectrometer based on wedge-shaped ion mirrors and the absence of electrostatic ion acceleration before mass analysis is discussed. Among advantages of the analyzer there are ability to provide temporal focusing of ions in a wide energy range (±20%), compactness of the analyzer, and minimization of the requirements for power supplies. The approach is expected to be profitable for standardless elemental analysis of solid samples, which should be possible at laser irradiation power density more than 3 × 10
9
W/cm
2
that ensures complete ionization of all elements in a laser plasma. The analytical signal of each element is formed as the sum of the signals for all charge states and the energy scan of the mass spectra is provided.
Title: Novel approach to constructing laser ionization elemental time-of-flight mass spectrometer
Description:
The main advantages of laser sampling are associated with following features: sample preparations as well as consumables are not needed, low risk of sample contamination, good spatial resolution.
In mass spectrometry, high laser irradiance can be used for both ablation and ionization processes.
The method is especially profitable in time-of-flight mass spectrometry.
A new principle of constructing laser ionization time-of-flight mass spectrometer based on wedge-shaped ion mirrors and the absence of electrostatic ion acceleration before mass analysis is discussed.
Among advantages of the analyzer there are ability to provide temporal focusing of ions in a wide energy range (±20%), compactness of the analyzer, and minimization of the requirements for power supplies.
The approach is expected to be profitable for standardless elemental analysis of solid samples, which should be possible at laser irradiation power density more than 3 × 10
9
W/cm
2
that ensures complete ionization of all elements in a laser plasma.
The analytical signal of each element is formed as the sum of the signals for all charge states and the energy scan of the mass spectra is provided.
Related Results
Flight Reservation System
Flight Reservation System
Flight reservation System is a computerized system used to store and retrieve information and conduct transactions related to air travel. The project is aimed at exposing the relev...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Dual Laser Method for Experimentally Weathering Planetary Regoliths
Dual Laser Method for Experimentally Weathering Planetary Regoliths
<p>Experimental space weathering&#8212;whether laser, thermal reduction, impact, or ion based&#8212;is a critical endeavor to accurately interpret spa...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...
Mechanosensory cephalic bristles mediate rapid flight initiation in endothermic hawkmoths
Mechanosensory cephalic bristles mediate rapid flight initiation in endothermic hawkmoths
AbstractEndothermic insects including bees, butterflies, and moths need to warm up their flight muscles before taking flight. For instance, diurnal butterflies bask in the sun to h...
Excimer Laser Micromachining of MEMS Materials
Excimer Laser Micromachining of MEMS Materials
Conventional photolithography-based microfabrication techniques are limited to two-dimensional fabrication and only particular materials can be used. Excimer laser micromachining e...
Laser show safety for smaller shows: The ILDA category a laser show standard
Laser show safety for smaller shows: The ILDA category a laser show standard
The International Laser Display Association has developed a “Category A Standard” for laser shows that ILDA considers to be generally recognized as safe under the conditions of the...
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
Development of a high intensity Mid-Ir OPCPA pumped by a HO:YLF amplifier
The continuous development of laser sources delivering ultra-short light pulses underpins much of the current progress in experimental science, particularly in the domain of physic...

