Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Particle position prediction based on Lagrangian coherency for flow over a cylinder in 4D-PTV

View through CrossRef
Recent developments in time-resolved Particle Tracking Velocimetry (4D-PTV) consistently improved tracking accuracy and robustness. We propose a novel technique named ”Lagrangian coherent predictor” to estimate particle positions within the 4D-PTV algorithm. We add spatial and temporal coherency information of neighbour particles to predict a single trajectory using Lagrangian Coherent Structures (LCS). We found that even a weak signal from coherent neighbour motions improves particle prediction accuracy in complex flow regions. We applied Finite Time Lyapunov Exponent (FTLE) to quantify local boundaries (i.e. ridges) of coherent motions. Synthetic analysis of the wake behind a smooth cylinder at Reynolds number equal to 3900 showed enhanced estimation compared with the recent predictor functions employed in 4D-PTV. Results of the experimental study of the same flow configuration are reported. We compared predicted positions with the optimised final positions of Shake The Box (STB). It was found that the Lagrangian coherent predictor succeeded in estimating particle positions with minimum deviation to the optimised positions.
Title: Particle position prediction based on Lagrangian coherency for flow over a cylinder in 4D-PTV
Description:
Recent developments in time-resolved Particle Tracking Velocimetry (4D-PTV) consistently improved tracking accuracy and robustness.
We propose a novel technique named ”Lagrangian coherent predictor” to estimate particle positions within the 4D-PTV algorithm.
We add spatial and temporal coherency information of neighbour particles to predict a single trajectory using Lagrangian Coherent Structures (LCS).
We found that even a weak signal from coherent neighbour motions improves particle prediction accuracy in complex flow regions.
We applied Finite Time Lyapunov Exponent (FTLE) to quantify local boundaries (i.
e.
ridges) of coherent motions.
Synthetic analysis of the wake behind a smooth cylinder at Reynolds number equal to 3900 showed enhanced estimation compared with the recent predictor functions employed in 4D-PTV.
Results of the experimental study of the same flow configuration are reported.
We compared predicted positions with the optimised final positions of Shake The Box (STB).
It was found that the Lagrangian coherent predictor succeeded in estimating particle positions with minimum deviation to the optimised positions.

Related Results

Lagrangian coherent track initialization
Lagrangian coherent track initialization
Advances in time-resolved three-dimensional Particle Tracking Velocimetry (4D-PTV) techniques have consistently revealed more accurate Lagrangian particle motions. A novel track in...
Numerical Investigations of a Rotating Wire-Wrapped Cylinder
Numerical Investigations of a Rotating Wire-Wrapped Cylinder
Previous investigations [1–3] on the effects of rotating cylinder with either a smooth surface or cylinders with different surface geometries, placed at either the leading or the t...
Effectiveness of robust optimization in intensity‐modulated proton therapy planning for head and neck cancers
Effectiveness of robust optimization in intensity‐modulated proton therapy planning for head and neck cancers
Purpose:Intensity‐modulated proton therapy (IMPT) is highly sensitive to uncertainties in beam range and patient setup. Conventionally, these uncertainties are dealt using geometri...
On the Flow-Excited Acoustic Resonance of Isolated Cylinder(s) in Cross-Flow
On the Flow-Excited Acoustic Resonance of Isolated Cylinder(s) in Cross-Flow
The flow-excited acoustic resonance of single and multiple cylinders in cross-flow is investigated experimentally. The effect of the cylinder(s) proximity to the acoustic particle ...
SU‐E‐T‐78: A Study of Dose Falloff Gradient in RapidArc Planning of Lung SBRT
SU‐E‐T‐78: A Study of Dose Falloff Gradient in RapidArc Planning of Lung SBRT
Purpose:Rapid dose falloff beyond PTV is an important criterion for normal tissue sparing in SBRT. RTOG protocols use D2cm and R50% for plan quality evaluation. This study is aimed...
Single-camera PTV within interfacially sheared drops in microgravity
Single-camera PTV within interfacially sheared drops in microgravity
Abstract Development of experimental methods for in situ particle tracking velocimetry (PTV) is fundamental for allowing measurement of moving systems non-tailored for velo...
VOLUMETRIC RIGIDITY OF HYDRAULIC SYSTEMS
VOLUMETRIC RIGIDITY OF HYDRAULIC SYSTEMS
A hydraulic drive is a set of interacting hydraulic devices that is designed to be ghosted by means of a working fluid under pressure. The main element in hydraulic drives most mac...
Coherency calculations in the presence of structural dip
Coherency calculations in the presence of structural dip
Abstract We have used crosscorrelation, semblance, and eigenstructure algorithms to estimate coherency. The first two algorithms calculate coherency over a multip...

Back to Top