Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Randomized Comparison of Xience V and Multi-Link Vision Coronary Stents in the Same Multivessel Patient With Chronic Kidney Disease (RENAL-DES) Study

View through CrossRef
Background— Percutaneous coronary interventions in patients with chronic kidney disease have shown suboptimal results. Drug-eluting stents (DES) might reduce the rate of target vessel revascularization in comparison with bare-metal stents (BMS) in patients with chronic kidney disease. However, given the multiple concomitant individual variables present in such patients, the comparison of neointimal growth after percutaneous coronary intervention is complex and difficult to assess. Methods and Results— Randomized Comparison of Xience V and Multi-Link Vision Coronary Stents in the Same Multivessel Patient with Chronic Kidney Disease (RENAL-DES) was a prospective, randomized, multicenter study to directly compare the efficacy in the prevention of clinical restenosis of everolimus-eluting stent (Xience V) and BMS with an identical design (Multi-Link Vision), both implanted in the same patient with multivessel coronary artery disease and chronic kidney disease (estimated glomerular filtration rate <60 mL/min). The primary end point of the study was the ischemia-driven target vessel revascularization as detected with myocardial scintigraphy at 12 months. In 215 patients, 512 coronary vessels were successfully treated with the randomly assigned DES (n=257) or BMS (n=255). At 1 year, the rate of ischemia-driven target vessel revascularization for DES and BMS groups was 2.7% (95% confidence interval, 1.1%–5.6%) and 11.4% (95% confidence interval, 7.8% to 16%), respectively, P <0.001. For the multivariate analysis, independent predictors of the ischemia-driven target vessel revascularization were BMS implantation (odds ratio, 4.95; 95% confidence interval, 2.1–11.6; P <0.001) and vessel size (odds ratio, 0.32; 95% confidence interval, 0.1–0.7; P =0.006). Conclusions— This is the first randomized trial showing a reduction of clinical restenosis with a new-generation DES in comparison with a BMS of equal design, in patients who have chronic kidney disease with multivessel coronary artery disease. Clinical Trial Registration— URL: http://clinicaltrials.gov . Unique identifier: NCT00818792.
Title: Randomized Comparison of Xience V and Multi-Link Vision Coronary Stents in the Same Multivessel Patient With Chronic Kidney Disease (RENAL-DES) Study
Description:
Background— Percutaneous coronary interventions in patients with chronic kidney disease have shown suboptimal results.
Drug-eluting stents (DES) might reduce the rate of target vessel revascularization in comparison with bare-metal stents (BMS) in patients with chronic kidney disease.
However, given the multiple concomitant individual variables present in such patients, the comparison of neointimal growth after percutaneous coronary intervention is complex and difficult to assess.
Methods and Results— Randomized Comparison of Xience V and Multi-Link Vision Coronary Stents in the Same Multivessel Patient with Chronic Kidney Disease (RENAL-DES) was a prospective, randomized, multicenter study to directly compare the efficacy in the prevention of clinical restenosis of everolimus-eluting stent (Xience V) and BMS with an identical design (Multi-Link Vision), both implanted in the same patient with multivessel coronary artery disease and chronic kidney disease (estimated glomerular filtration rate <60 mL/min).
The primary end point of the study was the ischemia-driven target vessel revascularization as detected with myocardial scintigraphy at 12 months.
In 215 patients, 512 coronary vessels were successfully treated with the randomly assigned DES (n=257) or BMS (n=255).
At 1 year, the rate of ischemia-driven target vessel revascularization for DES and BMS groups was 2.
7% (95% confidence interval, 1.
1%–5.
6%) and 11.
4% (95% confidence interval, 7.
8% to 16%), respectively, P <0.
001.
For the multivariate analysis, independent predictors of the ischemia-driven target vessel revascularization were BMS implantation (odds ratio, 4.
95; 95% confidence interval, 2.
1–11.
6; P <0.
001) and vessel size (odds ratio, 0.
32; 95% confidence interval, 0.
1–0.
7; P =0.
006).
Conclusions— This is the first randomized trial showing a reduction of clinical restenosis with a new-generation DES in comparison with a BMS of equal design, in patients who have chronic kidney disease with multivessel coronary artery disease.
Clinical Trial Registration— URL: http://clinicaltrials.
gov .
Unique identifier: NCT00818792.

Related Results

REGULAR ARTICLES
REGULAR ARTICLES
L. Cowen and C. J. Schwarz       657Les Radio‐tags, en raison de leur détectabilitéélevée, ...
Résumés des conférences JRANF 2021
Résumés des conférences JRANF 2021
able des matières Résumés. 140 Agenda Formation en Radioprotection JRANF 2021 Ouagadougou. 140 RPF 1 Rappel des unités de doses. 140 RPF 2 Risques déterministes et stochastique...
Renal Ewing Sarcoma: A Case Report and Literature Review
Renal Ewing Sarcoma: A Case Report and Literature Review
Abstract Introduction Primary renal Ewing sarcoma is an extremely rare and aggressive tumor, representing less than 1% of all renal tumors. This case report contributes valuable in...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash Abstract This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Avant-propos
Avant-propos
L’Agriculture Biologique (AB) se présente comme un mode de production agricole spécifique basé sur le respect d’un certain nombre de principes et de pratiques visant à réduire au m...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Objective In prior research, we employed artificial intelligence (AI) to distinguish different anatomical positions in the airway under bronchoscopy. We aimed to levera...

Back to Top