Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Deformation of Orthodontic Archwires Over Time

View through CrossRef
Abstract Most previous studies of archwire deformation over time (hereafter referred to as “time-dependent deformation of orthodontic wires”) have been conducted at a constant room temperature. In the clinical situation however, arch wires are exposed to 37°C as well as to periods of temperature increase when hot foods or fluids are ingested. The effects of the latter on time-dependent behaviour are largely unknown. Since the introduction of direct electric resistance heat treatment to superelastic nickel titanium wires, there have been no reports on its effect on time-dependent deformation. This study investigated the effects of repeated temperature increases (70°C) on stainless steel, nickel titanium and beta titanium wires. The wires were deflected by approximately 3 and 5 mm on two jigs for periods of 1 minute, 1,7,14 and 28 days. Permanent deformation was measured optically with a measuring microscope and the amount of time-dependent deformation was calculated. Beta titanium wires demonstrated the greatest amount of time-dependent deformation; followed by non-superelastic nickel titanium, stainless steel, and superelastic nickel titanium. Exposure to repeated temperature (70°C) increases and direct electric resistance heat treatment of superelastic nickel titanium did not affect time-dependent behaviour.
Title: Deformation of Orthodontic Archwires Over Time
Description:
Abstract Most previous studies of archwire deformation over time (hereafter referred to as “time-dependent deformation of orthodontic wires”) have been conducted at a constant room temperature.
In the clinical situation however, arch wires are exposed to 37°C as well as to periods of temperature increase when hot foods or fluids are ingested.
The effects of the latter on time-dependent behaviour are largely unknown.
Since the introduction of direct electric resistance heat treatment to superelastic nickel titanium wires, there have been no reports on its effect on time-dependent deformation.
This study investigated the effects of repeated temperature increases (70°C) on stainless steel, nickel titanium and beta titanium wires.
The wires were deflected by approximately 3 and 5 mm on two jigs for periods of 1 minute, 1,7,14 and 28 days.
Permanent deformation was measured optically with a measuring microscope and the amount of time-dependent deformation was calculated.
Beta titanium wires demonstrated the greatest amount of time-dependent deformation; followed by non-superelastic nickel titanium, stainless steel, and superelastic nickel titanium.
Exposure to repeated temperature (70°C) increases and direct electric resistance heat treatment of superelastic nickel titanium did not affect time-dependent behaviour.

Related Results

Understanding the Effects of Sterilisation Methods on Orthodontic Archwires Properties: A Review
Understanding the Effects of Sterilisation Methods on Orthodontic Archwires Properties: A Review
Sterilisation is the removal of all microorganisms, vegetative or spore-forming, from an article, surface or medium that can be accomplished through steam autoclaving, dry heat and...
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Orthodontic treatment also aims to maintain ideal periodontal health. Gingival/periodontal conditions and orthodontic interventions have a complicated relationship because orthodon...
Evaluation of conformity of preformed orthodontic archwires and dental arch form
Evaluation of conformity of preformed orthodontic archwires and dental arch form
ABSTRACT Introduction: The alterations in the arch form during treatment are dictated by the dimensions of the archwires. Objective: This study aimed to determine the mean arch...
Impact of Simulated Gastric Acid on Surface Roughness and Frictional Resistance of Orthodontic Archwires: An In vitro Study
Impact of Simulated Gastric Acid on Surface Roughness and Frictional Resistance of Orthodontic Archwires: An In vitro Study
Introduction: Acid regurgitation caused by gastro-oesophageal reflux disease can lead to decreases in intraoral pH below the critical pH for orthodontic appliances. Exposure of bra...
Evaluation of the effect of different toothpastes on the frictional resistance of aesthetic archwires: an in vitro study
Evaluation of the effect of different toothpastes on the frictional resistance of aesthetic archwires: an in vitro study
there has been a trend for using aesthetic orthodontic treatment by many patients recently. The aim of this study was to evaluate the brushing effect of three brands of toothpaste ...
Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
Sterilisation removes microorganisms in the vegetative or spore states from a material, surface or medium. Ensuring infection control is of utmost importance for health safety. Pat...

Back to Top