Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

TLC–Densitometric Analysis of Selected 5-Nitroimidazoles

View through CrossRef
Metronidazole, ornidazole, tinidazole, and secnidazole are 5-nitroimidazoles. The purpose of this work was to propose a new economical TLC–densitometric method to evaluate the chemical stability of metronidazole, secnidazole, ornidazole, and tinidazole under stress conditions. A forced degradation study was performed on silica gel and aqueous solutions at various pH values; the metronidazole, secnidazole, ornidazole, and tinidazole solutions were prepared in saline and in hydrogen peroxide, respectively. The samples of the 5-nitroimidazoles were heated. TLC analyses were performed on silica gel 60F254 using chloroform–methanol (9:1, v/v) as the mobile phase. As the TLC–densitometric method can effectively separate the metronidazole, secnidazole, ornidazole, and tinidazole from their degradation products which formed as a result of the stress studies, it is considered to can be a good alternative and important tool in the routine quality control and stability testing of metronidazole, secnidazole, ornidazole, and tinidazole in pharmaceutical formulations. The results indicate that the proposed TLC–densitometric method is cost-effective, rapid, specific, accurate, and precise; the TLC–densitometric method also realizes the criterion of the linearity. A major advantage of the proposed method is its low cost and ability to analyze the 5-nitroimidazole which was investigated and all its degradation products simultaneously.
Title: TLC–Densitometric Analysis of Selected 5-Nitroimidazoles
Description:
Metronidazole, ornidazole, tinidazole, and secnidazole are 5-nitroimidazoles.
The purpose of this work was to propose a new economical TLC–densitometric method to evaluate the chemical stability of metronidazole, secnidazole, ornidazole, and tinidazole under stress conditions.
A forced degradation study was performed on silica gel and aqueous solutions at various pH values; the metronidazole, secnidazole, ornidazole, and tinidazole solutions were prepared in saline and in hydrogen peroxide, respectively.
The samples of the 5-nitroimidazoles were heated.
TLC analyses were performed on silica gel 60F254 using chloroform–methanol (9:1, v/v) as the mobile phase.
As the TLC–densitometric method can effectively separate the metronidazole, secnidazole, ornidazole, and tinidazole from their degradation products which formed as a result of the stress studies, it is considered to can be a good alternative and important tool in the routine quality control and stability testing of metronidazole, secnidazole, ornidazole, and tinidazole in pharmaceutical formulations.
The results indicate that the proposed TLC–densitometric method is cost-effective, rapid, specific, accurate, and precise; the TLC–densitometric method also realizes the criterion of the linearity.
A major advantage of the proposed method is its low cost and ability to analyze the 5-nitroimidazole which was investigated and all its degradation products simultaneously.

Related Results

Total lung capacity without plethysmography
Total lung capacity without plethysmography
ABSTRACT Background Among the most basic measures of respiratory function is the total lung capacity (TLC). TLC is the pulmonar...
Role of total leukocyte count and C-reactive protein in diagnosis of acute appendicitis
Role of total leukocyte count and C-reactive protein in diagnosis of acute appendicitis
Background: Acute appendicitis is still one of the most common surgical emergencies. This study was conducted to check the sensitivity and specificity of Total leukocyte count (TLC...
Top-of-Line Spatial Corrosion Prediction in Gas Pipelines
Top-of-Line Spatial Corrosion Prediction in Gas Pipelines
The top-of-line corrosion (TLC) is corrosion observed at the upper section of a pipeline, as measured from the circumference of the pipe. The magnitude of TLC is mostly determined ...
Talc‐phengite‐albite assemblage in piemontite‐quartz schist of the Sanbagawa metamorphic belt, central Shikoku, Japan
Talc‐phengite‐albite assemblage in piemontite‐quartz schist of the Sanbagawa metamorphic belt, central Shikoku, Japan
Abstract The talc (Tlc) + phengite (Phn) + albite (Ab) assemblage is newly confirmed in MnOtotal‐rich (1.65 wt% in average) piemontite‐quartz schists from the intermediate‐ and hig...
Sour Top of Line Corrosion
Sour Top of Line Corrosion
Abstract Recent research has shown that sour top of line corrosion (TLC) is different from sweet TLC. The steel surface temperature is the most important factor for ...
Top of Line Corrosion Testing for a Gas Field with Acetic Acid and Low CO2
Top of Line Corrosion Testing for a Gas Field with Acetic Acid and Low CO2
Abstract Top of line corrosion (TLC) was studied in a flow loop under conditions representative for a gas field with a low CO2 partial pressure of 0.35 bar and prese...
Magnetic resonance elastography of the lungs: A repeatability and reproducibility study
Magnetic resonance elastography of the lungs: A repeatability and reproducibility study
Lung diseases are one of the leading causes of death worldwide, from which four million people die annually. Lung diseases are associated with changes in the mechanical properties ...

Back to Top