Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Enhanced Microwave Deicing Capacity of Cement Pavement with Carbon Fiber Screens

View through CrossRef
The combination of an absorbing structure and a road is a promising strategy for road deicing using microwaves. In this study, cement mortar (CM) specimens containing a carbon fiber screen (CFS) were prepared to concentrate electromagnetic losses on a road surface. The effect of the size and depth of the CFS on the surface heating efficiency of the microwave was studied and optimized, and a microwave deicing experiment was conducted. The results indicated that the destructive interference produced by the CFS led to the effective surface heating of the CM/CFS specimens. The optimal surface heating rate was 0.83 °C/s when the spacing, depth, and width of the CFS were 5.22, 13.31, and 2.80 mm, respectively. The deicing time was shortened by 21.68% from 83 to 65 s, and the heating rate increased by 17.14% from 0.70 to 0.82 °C/s for the specimen with CFS-1, which was 15 mm depth. Our results demonstrate that CM/CFS composite structures can be effectively applied to increase the capacity and accelerate the development of the microwave deicing of roads.
Title: Enhanced Microwave Deicing Capacity of Cement Pavement with Carbon Fiber Screens
Description:
The combination of an absorbing structure and a road is a promising strategy for road deicing using microwaves.
In this study, cement mortar (CM) specimens containing a carbon fiber screen (CFS) were prepared to concentrate electromagnetic losses on a road surface.
The effect of the size and depth of the CFS on the surface heating efficiency of the microwave was studied and optimized, and a microwave deicing experiment was conducted.
The results indicated that the destructive interference produced by the CFS led to the effective surface heating of the CM/CFS specimens.
The optimal surface heating rate was 0.
83 °C/s when the spacing, depth, and width of the CFS were 5.
22, 13.
31, and 2.
80 mm, respectively.
The deicing time was shortened by 21.
68% from 83 to 65 s, and the heating rate increased by 17.
14% from 0.
70 to 0.
82 °C/s for the specimen with CFS-1, which was 15 mm depth.
Our results demonstrate that CM/CFS composite structures can be effectively applied to increase the capacity and accelerate the development of the microwave deicing of roads.

Related Results

Experimental Study of Hybrid Deicing System
Experimental Study of Hybrid Deicing System
Abstract The hybrid deicing system combines the traditional electrothermal deicing system with the electro impulse deicing system. Firstly, the prototype design of t...
Micro/nano manufacturing aircraft surface with anti-icing and deicing performances: An overview
Micro/nano manufacturing aircraft surface with anti-icing and deicing performances: An overview
Abstract The aircraft surface is prone to icing when flying under windward conditions. It is required to protect the aircraft surface from icing for flight safety...
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
This study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contaminat...
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
ABSTRACT: The integrity of cement sheath is critical to oil and gas effective extraction, in which the cement displacement efficiency and solidify quality are the...
Development of a Continuous Testing Device for Pavement Structure Bearing Capacity
Development of a Continuous Testing Device for Pavement Structure Bearing Capacity
Pavement structure bearing capacity is an important evaluation parameter in pavement design, construction, maintenance management, and reconstruction, and is generally expressed by...
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
Cement-soil mixing piles have been commonly used to enhance the bearing capacity of fly ash stratum and mitigate the settlement damage to the surrounding environment. However, only...
Decision-making system and verification of pavement diseases treatment scheme for highway reconstruction and extension
Decision-making system and verification of pavement diseases treatment scheme for highway reconstruction and extension
Abstract Based on the case of a highway reconstruction and extension project in Guangdong Province, a decision-making system for the treatment of the old pavement...
Behavior of Nano Calcium Carbonate Modified Smart Cement Contaminated with Oil Based Drilling Mud
Behavior of Nano Calcium Carbonate Modified Smart Cement Contaminated with Oil Based Drilling Mud
Abstract As oil and gas exploration and production expands around the world, there are unique challenges in well construction beginning at the seafloor. There are se...

Back to Top