Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody test for diagnosis of rabies in animals in Bhutan
View through CrossRef
Abstract
Background: Rabies kills approximately 59,000 people in the world each year worldwide. Rapid and accurate diagnosis of rabies is important for instituting rapid containment measures and for advising the exposed people for postexposure treatment. The application of a rapid diagnostic tests in the field can greatly enhance disease surveillance and diagnostic activities, especially in resource poor settings. In this study, a total of 179 brain tissue samples collected from different rabies suspect animal species (113 dogs, 50 cattle, 10 cats, 3 goats, 2 horses, and 1 bear) were selected and tested using both rapid immunochromatographic kit and the reference standard fluorescent antibody test (FAT). We evaluated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a rapid antigen detection test kit produced by BioNote, Inc. (Hwaseong-si, Korea) relative to a FAT for its fit-for-purpose for confirmation of clinical cases of rabies for early response and enhancing rabies surveillance. Results: Among 179 samples examined in this study, there was a concordance in results by the rapid test and FAT in 115 positive samples and 54 negative samples. Test results were discordant in 10 samples which were positive by FAT, but negative (false negative) by rapid kit. The rapid test kit showed a sensitivity of 92% (95% CI: 85.9 – 95.6) and specificity of 100% (95% CI: 93.4 – 100) using FAT as the reference standard. The positive and negative predictive values were found to be 100% (95% CI:96.7 – 100) and 84.4% (95% CI: 73.6 – 91.3), respectively. Overall, there was 94.4% (95% CI: 90 – 96.9) test agreement between rapid test and FAT (Kappa value = 0.874) with a positive percent agreement and negative percent agreement of 92 and 100%, respectively. Conclusions: Our finding demonstrated that the rapid test kit (BioNote) can be used for rabies surveillance and confirming clinical case of rabies in animals for making rapid decisions particularly controlling rabies outbreaks in resource poor settings.
Springer Science and Business Media LLC
Tenzin Tenzin
Kelzang Lhamo
Purna B Rai
Dawa Tshering
Pema Jamtsho
Jamyang Namgyal
Thrinang Wangdi
Sangay Letho
Tuku Rai
Sonam Jamtsho
Chendu Dorji
Sangay Rinchen
Lungten Lungten
Karma Wangmo
Lungten Lungten
Pema Wangchuk
Tshewang Gempo
Kezang Jigme
Karma Phuntshok
Tenzinla Tenzinla
Ratna B Gurung
Kinzang Dukpa
Title: Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody test for diagnosis of rabies in animals in Bhutan
Description:
Abstract
Background: Rabies kills approximately 59,000 people in the world each year worldwide.
Rapid and accurate diagnosis of rabies is important for instituting rapid containment measures and for advising the exposed people for postexposure treatment.
The application of a rapid diagnostic tests in the field can greatly enhance disease surveillance and diagnostic activities, especially in resource poor settings.
In this study, a total of 179 brain tissue samples collected from different rabies suspect animal species (113 dogs, 50 cattle, 10 cats, 3 goats, 2 horses, and 1 bear) were selected and tested using both rapid immunochromatographic kit and the reference standard fluorescent antibody test (FAT).
We evaluated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a rapid antigen detection test kit produced by BioNote, Inc.
(Hwaseong-si, Korea) relative to a FAT for its fit-for-purpose for confirmation of clinical cases of rabies for early response and enhancing rabies surveillance.
Results: Among 179 samples examined in this study, there was a concordance in results by the rapid test and FAT in 115 positive samples and 54 negative samples.
Test results were discordant in 10 samples which were positive by FAT, but negative (false negative) by rapid kit.
The rapid test kit showed a sensitivity of 92% (95% CI: 85.
9 – 95.
6) and specificity of 100% (95% CI: 93.
4 – 100) using FAT as the reference standard.
The positive and negative predictive values were found to be 100% (95% CI:96.
7 – 100) and 84.
4% (95% CI: 73.
6 – 91.
3), respectively.
Overall, there was 94.
4% (95% CI: 90 – 96.
9) test agreement between rapid test and FAT (Kappa value = 0.
874) with a positive percent agreement and negative percent agreement of 92 and 100%, respectively.
Conclusions: Our finding demonstrated that the rapid test kit (BioNote) can be used for rabies surveillance and confirming clinical case of rabies in animals for making rapid decisions particularly controlling rabies outbreaks in resource poor settings.
Related Results
Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody Test for Diagnosis of Rabies in Animals in Bhutan
Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody Test for Diagnosis of Rabies in Animals in Bhutan
Abstract
Background Rabies kills approximately 59,000 people in the world each year worldwide. Rapid and accurate diagnosis of rabies is important for instituting rapid con...
Knowledge, Attitude, and Practice (KAP) towards Rabies, its Suspected Cases and Associated Economic Impact in West Shewa Zone, Oromia, Ethiopia
Knowledge, Attitude, and Practice (KAP) towards Rabies, its Suspected Cases and Associated Economic Impact in West Shewa Zone, Oromia, Ethiopia
Abstract
Background
Rabies is a neglected zoonotic disease that affects many developing countries in which it is endemic, inclu...
Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody test for diagnosis of rabies in animals in Bhutan
Evaluation of a Rapid Immunochromatographic test kit to the Gold Standard Fluorescent Antibody test for diagnosis of rabies in animals in Bhutan
Abstract
Background: Rabies kills approximately 59,000 people in the world each year worldwide. Rapid and accurate diagnosis of rabies is important for instituting rapid co...
Understanding Strategies for Implementing Integrated Information Systems for Rabies Surveillance
Understanding Strategies for Implementing Integrated Information Systems for Rabies Surveillance
Rabies continues to be one of the most perilous viral diseases that affect the nervous system and remains a significant threat to public health across the globe. Available data tha...
Understanding Strategies for Implementing Integrated Information Systems for Rabies Surveillance
Understanding Strategies for Implementing Integrated Information Systems for Rabies Surveillance
Rabies continues to be one of the most perilous viral diseases that affect the nervous system and remains a significant threat to public health across the globe. Available data tha...
Establishing the Basis for Rabies Control in Liberia
Establishing the Basis for Rabies Control in Liberia
Abstract
In 2017, the Swiss Tropical and Public Health Institute established a partnership with the Liberian Ministry of Agriculture on a rabies project entitled “Multice...
Pemetaan dan Analisis Kejadian Rabies di Kabupaten Buleleng Tahun 2010-2016
Pemetaan dan Analisis Kejadian Rabies di Kabupaten Buleleng Tahun 2010-2016
Rabies merupakan salah satu penyakit menular yang masih menjadi permasalahan di Indonesia terutama di Pulau Bali. Kejadian rabies di Pulau Bali khususnya di Kabupaten Buleleng masi...
Assessment of Dog Owners’ Knowledge, Attitude and Practice Towards Rabies in Sabon Gari Local Government Area, Kaduna State, Nigeria
Assessment of Dog Owners’ Knowledge, Attitude and Practice Towards Rabies in Sabon Gari Local Government Area, Kaduna State, Nigeria
Rabies is a fatal viral zoonosis of serious public health concern worldwide that occurs in over 150 countries. In Nigeria, the disease is endemic and remains neglected, misdiagnos...