Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

LOCALIZED MODES AND DIVACANCY ABSORPTION IN OXYGEN ION IMPLANTED Si

View through CrossRef
Optical absorption bands characteristic of localized vibrational modes for both interstitial and substitutional oxygen have been observed in crystalline Si implanted with 220-keV oxygen ions at 300°K. In addition, the fluence dependences for the vibrational modes and also for an electronic transition of the divacancy (1.8-μ band) have been measured. Implanted oxygen ions are found to enhance divacancy formation. This effect was not observed for Sb implantation. The sum of the observed interstitial and substitutional oxygen centers is approximately equal to the number of implanted oxygen ions. An ion fluence 300 times larger than that to detect divacancies was required to detect the vibrational modes of oxygen as expected from the relative production rates and absorption coefficients. At these high fluences the strengths of the vibrational bands increase in magnitude with fluence while the divacancy band decreases. At even higher fluences amorphous layer formation, as indicated by a milky coloration of the surface, caused a decrease in the spacing of optical interference fringes and in the magnitude of the oxygen vibrational bands.
Title: LOCALIZED MODES AND DIVACANCY ABSORPTION IN OXYGEN ION IMPLANTED Si
Description:
Optical absorption bands characteristic of localized vibrational modes for both interstitial and substitutional oxygen have been observed in crystalline Si implanted with 220-keV oxygen ions at 300°K.
In addition, the fluence dependences for the vibrational modes and also for an electronic transition of the divacancy (1.
8-μ band) have been measured.
Implanted oxygen ions are found to enhance divacancy formation.
This effect was not observed for Sb implantation.
The sum of the observed interstitial and substitutional oxygen centers is approximately equal to the number of implanted oxygen ions.
An ion fluence 300 times larger than that to detect divacancies was required to detect the vibrational modes of oxygen as expected from the relative production rates and absorption coefficients.
At these high fluences the strengths of the vibrational bands increase in magnitude with fluence while the divacancy band decreases.
At even higher fluences amorphous layer formation, as indicated by a milky coloration of the surface, caused a decrease in the spacing of optical interference fringes and in the magnitude of the oxygen vibrational bands.

Related Results

High Concentration Oxygen and Hypercapnia in Respiratory Disease
High Concentration Oxygen and Hypercapnia in Respiratory Disease
<p>Oxygen-induced elevations in arterial carbon dioxide tension have been demonstrated in patients with chronic obstructive pulmonary disease (COPD), asthma, pneumonia, obesi...
Closed-Loop Oxygen Control
Closed-Loop Oxygen Control
<p>Guidelines recommend that oxygen should be titrated to achieve a target oxygen saturation (SpO2 ) range in acutely unwell patients, a concept colloquially known as “swimmi...
The influence of nanostructure formation on properties for Cr implanted PET
The influence of nanostructure formation on properties for Cr implanted PET
ABSTRACTPolyethylene terephthalate (PET) has been modified by Cr ion implantation with a dose range from 1×1016to 2×1017ions /cm2 using a metal vapor vacuum arc MEVVA source. The s...
Effects of Ion Implantation on Protein Adsorption onto Silicone Rubber
Effects of Ion Implantation on Protein Adsorption onto Silicone Rubber
AbstractA study has been made on the surface wettability, atomic ratio, chemical structure, chemical bonding states and plasma protein adsorption of ion implanted silicone rubbers....
First-principle study of the oxygen adsorption on Zr surface with Nb or Ge
First-principle study of the oxygen adsorption on Zr surface with Nb or Ge
It is observed that the addition of Nb or Ge to Zr alloy can improve its corrosion resistance. Because of the extreme importance of the mechanism of oxidation to corrosion properti...
(Invited) 4H-SiC Ion Implanted Bipolar Junctions: Relevance of the 1950°C Temperature for Post Implantation Annealing
(Invited) 4H-SiC Ion Implanted Bipolar Junctions: Relevance of the 1950°C Temperature for Post Implantation Annealing
Ion implantation is a relevant technology for the fabrication of p-n interfaces in several SiC electronic devices; ion implanted source/drain and body regions in commercial 4H-SiC ...
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
Simulation of unidirectional ion ejection in linear ion traps with asymmetric radiofrequency voltage
RationaleLinear ion traps with simplified structure have been widely used in miniaturized mass spectrometers. However, linear ion traps usually have low ion detection efficiency wh...
Ion extraction experiment for electron cyclotron resonance ion source with different magnetic topology
Ion extraction experiment for electron cyclotron resonance ion source with different magnetic topology
Electron cyclotron resonance ion source (ECRIS) for space propulsion requires to be compact and efficient. In this work, ECRIS, which generates magnetic field through permanent mag...

Back to Top