Javascript must be enabled to continue!
Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
View through CrossRef
AbstractCardiovascular magnetic resonance (CMR) imaging provides reliable assessments of biventricular morphology and function. Since manual post-processing is time-consuming and prone to observer variability, efforts have been directed towards novel artificial intelligence-based fully automated analyses. Hence, we sought to investigate the impact of artificial intelligence-based fully automated assessments on the inter-study variability of biventricular volumes and function. Eighteen participants (11 with normal, 3 with heart failure and preserved and 4 with reduced ejection fraction (EF)) underwent serial CMR imaging at in median 63 days (range 49–87) interval. Short axis cine stacks were acquired for the evaluation of left ventricular (LV) mass, LV and right ventricular (RV) end-diastolic, end-systolic and stroke volumes as well as EF. Assessments were performed manually (QMass, Medis Medical Imaging Systems, Leiden, Netherlands) by an experienced (3 years) and inexperienced reader (no active reporting, 45 min of training with five cases from the SCMR consensus data) as well as fully automated (suiteHEART, Neosoft, Pewaukee, WI, USA) without any manual corrections. Inter-study reproducibility was overall excellent with respect to LV volumetric indices, best for the experienced observer (intraclass correlation coefficient (ICC) > 0.98, coefficient of variation (CoV, < 9.6%) closely followed by automated analyses (ICC > 0.93, CoV < 12.4%) and lowest for the inexperienced observer (ICC > 0.86, CoV < 18.8%). Inter-study reproducibility of RV volumes was excellent for the experienced observer (ICC > 0.88, CoV < 10.7%) but considerably lower for automated and inexperienced manual analyses (ICC > 0.69 and > 0.46, CoV < 22.8% and < 28.7% respectively). In this cohort, fully automated analyses allowed reliable serial investigations of LV volumes with comparable inter-study reproducibility to manual analyses performed by an experienced CMR observer. In contrast, RV automated quantification with current algorithms still relied on manual post-processing for reliability.
Springer Science and Business Media LLC
Title: Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
Description:
AbstractCardiovascular magnetic resonance (CMR) imaging provides reliable assessments of biventricular morphology and function.
Since manual post-processing is time-consuming and prone to observer variability, efforts have been directed towards novel artificial intelligence-based fully automated analyses.
Hence, we sought to investigate the impact of artificial intelligence-based fully automated assessments on the inter-study variability of biventricular volumes and function.
Eighteen participants (11 with normal, 3 with heart failure and preserved and 4 with reduced ejection fraction (EF)) underwent serial CMR imaging at in median 63 days (range 49–87) interval.
Short axis cine stacks were acquired for the evaluation of left ventricular (LV) mass, LV and right ventricular (RV) end-diastolic, end-systolic and stroke volumes as well as EF.
Assessments were performed manually (QMass, Medis Medical Imaging Systems, Leiden, Netherlands) by an experienced (3 years) and inexperienced reader (no active reporting, 45 min of training with five cases from the SCMR consensus data) as well as fully automated (suiteHEART, Neosoft, Pewaukee, WI, USA) without any manual corrections.
Inter-study reproducibility was overall excellent with respect to LV volumetric indices, best for the experienced observer (intraclass correlation coefficient (ICC) > 0.
98, coefficient of variation (CoV, < 9.
6%) closely followed by automated analyses (ICC > 0.
93, CoV < 12.
4%) and lowest for the inexperienced observer (ICC > 0.
86, CoV < 18.
8%).
Inter-study reproducibility of RV volumes was excellent for the experienced observer (ICC > 0.
88, CoV < 10.
7%) but considerably lower for automated and inexperienced manual analyses (ICC > 0.
69 and > 0.
46, CoV < 22.
8% and < 28.
7% respectively).
In this cohort, fully automated analyses allowed reliable serial investigations of LV volumes with comparable inter-study reproducibility to manual analyses performed by an experienced CMR observer.
In contrast, RV automated quantification with current algorithms still relied on manual post-processing for reliability.
Related Results
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Mediator kinase submodule-dependent regulation of cardiac transcription
Mediator kinase submodule-dependent regulation of cardiac transcription
<p>Pathological cardiac remodeling results from myocardial stresses including pressure and volume overload, neurohumoral activation, myocardial infarction, and hypothyroidism...
A Pipeline for Automated Coordinate Assignment in Anatomically Accurate Biventricular Models
A Pipeline for Automated Coordinate Assignment in Anatomically Accurate Biventricular Models
AbstractThere is an increased interest, in the field of cardiac modeling, for an improved coordinate system that can consistently describe local position within a heart geometry ac...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
Hybrid Cardiac Imaging
Hybrid Cardiac Imaging
Abstract
Assessment of both coronary anatomy and myocardial perfusion are equally important for the appropriate treatment of patients with stable coronary artery dis...
Diagnostic Accuracy of Ultrasonography Versus Magnetic Resonance Imaging in the Detection of Endometrial Carcinoma Keeping Histopathology as Gold Standard
Diagnostic Accuracy of Ultrasonography Versus Magnetic Resonance Imaging in the Detection of Endometrial Carcinoma Keeping Histopathology as Gold Standard
Objective: To calculate the diagnostic accuracy of Ultrasonography versus Magnetic Resonance Imaging in detecting endometrial carcinoma with histopathology kept as a gold standard....
Echocardiographic characteristics of cardiac myxoma
Echocardiographic characteristics of cardiac myxoma
Abstract
Background
Accurate imaging differentiation of various cardiac masses is pivotal due to differences in clinical managem...
Two‐Year Performance of a Preshaped Lead for Left Ventricular Stimulation
Two‐Year Performance of a Preshaped Lead for Left Ventricular Stimulation
Important goals, when implanting a cardiac resynchronization therapy (CRT) system, are to reach a stable LV lead position in a suitable coronary sinus (CS) tributary associated wit...


