Inter-study reproducibility of cardiovascular magnetic resonance-derived hemodynamic force assessments
View through CrossRef
AbstractCardiovascular magnetic resonance (CMR)-derived hemodynamic force (HDF) analyses have been introduced recently enabling more in-depth cardiac function evaluation. Inter-study reproducibility is important for a widespread clinical use but has not been quantified for this novel CMR post-processing tool yet. Serial CMR imaging was performed in 11 healthy participants in a median interval of 63 days (range 49–87). HDF assessment included left ventricular (LV) longitudinal, systolic peak and impulse, systolic/diastolic transition, diastolic deceleration as well as atrial thrust acceleration forces. Inter-study reproducibility and study sample sizes required to demonstrate 10%, 15% or 20% relative changes of HDF measurements were calculated. In addition, intra- and inter-observer analyses were performed. Intra- and inter-observer reproducibility was excellent for all HDF parameters according to intraclass correlation coefficient (ICC) values (> 0.80 for all). Inter-study reproducibility of all HDF parameters was excellent (ICC ≥ 0.80 for all) with systolic parameters showing lower coeffients of variation (CoV) than diastolic measurements (CoV 15.2% for systolic impulse vs. CoV 30.9% for atrial thrust). Calculated sample sizes to detect relative changes ranged from n = 12 for the detection of a 20% relative change in systolic impulse to n = 200 for the detection of 10% relative change in atrial thrust. Overall inter-study reproducibility of CMR-derived HDF assessments was sufficient with systolic HDF measurements showing lower inter-study variation than diastolic HDF analyses.
Springer Science and Business Media LLC
Title: Inter-study reproducibility of cardiovascular magnetic resonance-derived hemodynamic force assessments
Description:
AbstractCardiovascular magnetic resonance (CMR)-derived hemodynamic force (HDF) analyses have been introduced recently enabling more in-depth cardiac function evaluation.
Inter-study reproducibility is important for a widespread clinical use but has not been quantified for this novel CMR post-processing tool yet.
Serial CMR imaging was performed in 11 healthy participants in a median interval of 63 days (range 49–87).
HDF assessment included left ventricular (LV) longitudinal, systolic peak and impulse, systolic/diastolic transition, diastolic deceleration as well as atrial thrust acceleration forces.
Inter-study reproducibility and study sample sizes required to demonstrate 10%, 15% or 20% relative changes of HDF measurements were calculated.
In addition, intra- and inter-observer analyses were performed.
Intra- and inter-observer reproducibility was excellent for all HDF parameters according to intraclass correlation coefficient (ICC) values (> 0.
80 for all).
Inter-study reproducibility of all HDF parameters was excellent (ICC ≥ 0.
80 for all) with systolic parameters showing lower coeffients of variation (CoV) than diastolic measurements (CoV 15.
2% for systolic impulse vs.
CoV 30.
9% for atrial thrust).
Calculated sample sizes to detect relative changes ranged from n = 12 for the detection of a 20% relative change in systolic impulse to n = 200 for the detection of 10% relative change in atrial thrust.
Overall inter-study reproducibility of CMR-derived HDF assessments was sufficient with systolic HDF measurements showing lower inter-study variation than diastolic HDF analyses.
Related Results
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
Analysis of magnetohydrodynamic drag character for hypersonic vehicles
In hypersonic flight, a very high temperature area can form ahead of the nose of aerocraft due to the shock aerodynamic heating, which leads to air weakly ionized. Many researchers...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...
Is the nuclear attraction just magnetic moment interaction between nucleons?
Is the nuclear attraction just magnetic moment interaction between nucleons?
Abstract
By reexamining the magnetic moment interaction between nucleons, it is argued in this article that the formula for calculating magnetic induction generated by magn...
Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
Impact of fully automated assessment on interstudy reproducibility of biventricular volumes and function in cardiac magnetic resonance imaging
AbstractCardiovascular magnetic resonance (CMR) imaging provides reliable assessments of biventricular morphology and function. Since manual post-processing is time-consuming and p...
Association between dog and cat ownership with cardiovascular disease: A systematic review and meta-analysis
Association between dog and cat ownership with cardiovascular disease: A systematic review and meta-analysis
Background: Numerous studies have described the correlation of pet ownership with cardiovascular diseases, with dog and cat ownership emerging as the predominant forms of pet compa...
Mechanisms of E-cadherin force transmission
Mechanisms of E-cadherin force transmission
<p>Cells are subject to a wide variety of forces throughout their lifetimes. During epithelial morphogenesis, epithelial cells form sheets of cells that line the cavities and...
Unveiling the Burden of Cardiovascular Disorders in Pediatric Stroke—Insights from Pakistan
Unveiling the Burden of Cardiovascular Disorders in Pediatric Stroke—Insights from Pakistan
Pediatric stroke, though relatively uncommon, poses significant clinical challenges due to its high rates of morbidity and mortality [1]. Its incidence varies with age, remaining l...
Hemodynamic phenotypes linked to high-altitude subclinical organ damage
Hemodynamic phenotypes linked to high-altitude subclinical organ damage
Abstract
Background
Chronic exposure to high-altitude hypoxia imposes sustained cardiovascular stress, yet hemodynamic adaptati...