Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Modular Dual Mobility Articulation in primary and revision hip arthroplasty: lights and shadows

View through CrossRef
Abstract Purpose The use of dual mobility cups in total hip arthroplasty has gained popularity in light of the fact it enables to reduce dislocation through increased jumping distance (JD) and impingement-free arc of movement. Modular Dual Mobility Cup (modular DMC) systems have been recently introduced to enable the use of dual mobility cups with standard metal-backed shells. The objective of this study was twofold: calculate the JD for each modular DMC system and conduct a systematic literature review to report clinical outcomes and reasons for failure of this construct. Methods The JD was calculated using the Sariali formula: JD = 2Rsin [(π/2 – Ψ – arcsin (offset/R)) / 2]. A qualitative systematic literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive search for English and French articles between January 2000 and July 2020 was run on PubMed, EMBASE, Google Scholar, and Scopus with the primary objective of finding articles about modular DMC systems. Results We identified eight 8 different manufacturers of modular DMC systems and 327 publications on the subject. After screening for duplicates and eligibility, we identified 229 publications: 206 articles were excluded because they contained no reports on modular DMC systems, whereas other three were not included because they focused on biomechanical aspects. Among the 11 included articles, 2 were prospective case series, 9 were retrospective case series. True dislocation occurred in 25 cases (0.9%) and six of them were solved by closed reduction without necessity of revision, while all 5 intraprosthetic dislocations were operated. Conclusions modular DMCs are a valid method to deal with complex THA instability, with good clinical and patient-reported outcomes, low complication rates, and low revision rates at early follow-up. We would advise cautious optimism on the role of modular DMC implants, as it seems safer to use ceramic instead of metallic heads whenever possible to avoid the increase cobalt and chromium trace ion serum levels.
Title: Modular Dual Mobility Articulation in primary and revision hip arthroplasty: lights and shadows
Description:
Abstract Purpose The use of dual mobility cups in total hip arthroplasty has gained popularity in light of the fact it enables to reduce dislocation through increased jumping distance (JD) and impingement-free arc of movement.
Modular Dual Mobility Cup (modular DMC) systems have been recently introduced to enable the use of dual mobility cups with standard metal-backed shells.
The objective of this study was twofold: calculate the JD for each modular DMC system and conduct a systematic literature review to report clinical outcomes and reasons for failure of this construct.
Methods The JD was calculated using the Sariali formula: JD = 2Rsin [(π/2 – Ψ – arcsin (offset/R)) / 2].
A qualitative systematic literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.
A comprehensive search for English and French articles between January 2000 and July 2020 was run on PubMed, EMBASE, Google Scholar, and Scopus with the primary objective of finding articles about modular DMC systems.
Results We identified eight 8 different manufacturers of modular DMC systems and 327 publications on the subject.
After screening for duplicates and eligibility, we identified 229 publications: 206 articles were excluded because they contained no reports on modular DMC systems, whereas other three were not included because they focused on biomechanical aspects.
Among the 11 included articles, 2 were prospective case series, 9 were retrospective case series.
True dislocation occurred in 25 cases (0.
9%) and six of them were solved by closed reduction without necessity of revision, while all 5 intraprosthetic dislocations were operated.
Conclusions modular DMCs are a valid method to deal with complex THA instability, with good clinical and patient-reported outcomes, low complication rates, and low revision rates at early follow-up.
We would advise cautious optimism on the role of modular DMC implants, as it seems safer to use ceramic instead of metallic heads whenever possible to avoid the increase cobalt and chromium trace ion serum levels.

Related Results

Intraprosthetic dislocation after a revision hip replacement: a case report
Intraprosthetic dislocation after a revision hip replacement: a case report
ABSTRACT BACKGROUND: The dual mobility cup (DMC) was initially design in 1974. It was designed to offer additional stability in total hip arthroplasty (THA) and to prevent disloca...
Tapered Modular Femoral Stems for Revision Total Hip Arthroplasty Show Excellent Mid-Term Survivorship
Tapered Modular Femoral Stems for Revision Total Hip Arthroplasty Show Excellent Mid-Term Survivorship
Introduction: Revision total hip arthroplasty (THA) can be challenging in the face of proximal femoral bone loss, catastrophic implant failure, or recurrent hip instability. Tapere...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Complications of revision knee arthroplasty
Complications of revision knee arthroplasty
Due to the growing scale of arthroplasty and the widening of indications for knee joint replacement, the durability of joint functioning has become a critical issue. Untimely diagn...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
Evolution of disability in adults with hip arthroplasty: A national longitudinal study
AbstractObjectiveTo describe disability in individuals with hip arthroplasty and its evolution over 2 years compared with that in the general population, and to compare the degree ...
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
Analysis of Risk Factors for Perioperative Transfusion in Hip Arthroplasty and Modeling of a Nomogram
AIM: To investigate the risk factors of perioperative transfusion in hip arthroplasty and to construct a nomogram model to predict the risk of transfusion. METHODS: A total of 120 ...

Back to Top