Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A new laser–based and ultra–portable gas sensor for indoor and outdoor formaldehyde (HCHO) monitoring

View through CrossRef
Abstract. In this work, a new commercially available, laser–based, and ultra–portable formaldehyde (HCHO) gas sensor is characterized, and its usefulness for monitoring HCHO mixing ratios in both indoor and outdoor environments is assessed. Stepped calibrations and intercomparison with well–established laser–induced fluorescence (LIF) instrumentation allow a performance evaluation of the absorption-based, mid–infrared HCHO sensor from Aeris Technologies, Inc. The Aeris sensor displays linear behavior (R-squared > 0.940) and shows good agreement with LIF instruments from Harvard and NASA Goddard. A non–linear least–squares fitting algorithm developed independently of the sensor's manufacturer to fit the sensor's raw absorption data during post-processing further improves instrument performance. The 3σ limit of detection (LOD) for a 15 and 60 min integration time is 690 and 420 pptv HCHO, respectively, for mixing ratios reported in real-time, though the LOD improves to 570 and 300 pptv HCHO, respectively, during post-processing. This sub-ppbv precision is sufficient for most HCHO levels measured in indoor and outdoor environments. While the compact Aeris sensor is currently not a replacement for the most sensitive research–grade instrumentation available, its usefulness for monitoring HCHO is clearly demonstrated.
Title: A new laser–based and ultra–portable gas sensor for indoor and outdoor formaldehyde (HCHO) monitoring
Description:
Abstract.
In this work, a new commercially available, laser–based, and ultra–portable formaldehyde (HCHO) gas sensor is characterized, and its usefulness for monitoring HCHO mixing ratios in both indoor and outdoor environments is assessed.
Stepped calibrations and intercomparison with well–established laser–induced fluorescence (LIF) instrumentation allow a performance evaluation of the absorption-based, mid–infrared HCHO sensor from Aeris Technologies, Inc.
The Aeris sensor displays linear behavior (R-squared > 0.
940) and shows good agreement with LIF instruments from Harvard and NASA Goddard.
A non–linear least–squares fitting algorithm developed independently of the sensor's manufacturer to fit the sensor's raw absorption data during post-processing further improves instrument performance.
The 3σ limit of detection (LOD) for a 15 and 60 min integration time is 690 and 420 pptv HCHO, respectively, for mixing ratios reported in real-time, though the LOD improves to 570 and 300 pptv HCHO, respectively, during post-processing.
This sub-ppbv precision is sufficient for most HCHO levels measured in indoor and outdoor environments.
While the compact Aeris sensor is currently not a replacement for the most sensitive research–grade instrumentation available, its usefulness for monitoring HCHO is clearly demonstrated.

Related Results

The Annual Characteristics of Rainwater HCHO in Guiyang City, Southwest of China
The Annual Characteristics of Rainwater HCHO in Guiyang City, Southwest of China
AbstractHCHO is ubiquitous and important chemical constitutes in the troposphere. The concentrations of the HCHO (aq) in the rainwater were measured in the Guiyang city, southeaste...
Hidden formaldehyde in cosmetic products
Hidden formaldehyde in cosmetic products
AbstractBackgroundFormaldehyde is a common cause of contact allergy. Hidden formaldehyde, that is, formaldehyde in products without formaldehyde releasers, has previously been dete...
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae s.l. in Northern Ghana
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae s.l. in Northern Ghana
Abstract Background: Selection pressure from continued exposure to insecticides drives the development of insecticide resistance and changes in resting behavior of malaria ...
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae s.l. in Northern Ghana
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae s.l. in Northern Ghana
Abstract Background Selection pressure from continued exposure to insecticides drives the development of insecticide resistance and changes in resting behavior of malaria v...
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae in Northern Ghana
Insecticide resistance in indoor and outdoor-resting Anopheles gambiae in Northern Ghana
Abstract Background Selection pressure from continued exposure to insecticides drives development of insecticide resistance and changes in resting behaviour of malaria vect...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Formaldehyde Activation and Dissociation on Defective Co-doped CeO 2 (111): First-Principles Calculations
Formaldehyde Activation and Dissociation on Defective Co-doped CeO 2 (111): First-Principles Calculations
DFT+U calculations have been utilized to explore theoretically three potential pathways of HCHO oxidation on Co-doped CeO 2 (111) with O-vacancy...
Mapping isoprene emissions over North America using formaldehyde column observations from space
Mapping isoprene emissions over North America using formaldehyde column observations from space
We present a methodology for deriving emissions of volatile organic compounds (VOC) using space‐based column observations of formaldehyde (HCHO) and apply it to data from the Globa...

Back to Top