Dynamic CBCT imaging using prior model-free spatiotemporal implicit neural representation (PMF-STINR)
View through CrossRef
Abstract
Objective. Dynamic cone-beam computed tomography (CBCT) can capture high-spatial-resolution, time-varying images for motion monitoring, patient setup, and adaptive planning of radiotherapy. However, dynamic CBCT reconstruction is an extremely ill-posed spatiotemporal inverse problem, as each CBCT volume in the dynamic sequence is only captured by one or a few x-ray projections, due to the slow gantry rotation speed and the fast anatomical motion (e.g. breathing). Approach. We developed a machine learning-based technique, prior-model-free spatiotemporal implicit neural representation (PMF-STINR), to reconstruct dynamic CBCTs from sequentially acquired x-ray projections. PMF-STINR employs a joint image reconstruction and registration approach to address the under-sampling challenge, enabling dynamic CBCT reconstruction from singular x-ray projections. Specifically, PMF-STINR uses spatial implicit neural representations to reconstruct a reference CBCT volume, and it applies temporal INR to represent the intra-scan dynamic motion of the reference CBCT to yield dynamic CBCTs. PMF-STINR couples the temporal INR with a learning-based B-spline motion model to capture time-varying deformable motion during the reconstruction. Compared with the previous methods, the spatial INR, the temporal INR, and the B-spline model of PMF-STINR are all learned on the fly during reconstruction in a one-shot fashion, without using any patient-specific prior knowledge or motion sorting/binning. Main results. PMF-STINR was evaluated via digital phantom simulations, physical phantom measurements, and a multi-institutional patient dataset featuring various imaging protocols (half-fan/full-fan, full sampling/sparse sampling, different energy and mAs settings, etc). The results showed that the one-shot learning-based PMF-STINR can accurately and robustly reconstruct dynamic CBCTs and capture highly irregular motion with high temporal (∼ 0.1 s) resolution and sub-millimeter accuracy. Significance. PMF-STINR can reconstruct dynamic CBCTs and solve the intra-scan motion from conventional 3D CBCT scans without using any prior anatomical/motion model or motion sorting/binning. It can be a promising tool for motion management by offering richer motion information than traditional 4D-CBCTs.
Title: Dynamic CBCT imaging using prior model-free spatiotemporal implicit neural representation (PMF-STINR)
Description:
Abstract
Objective.
Dynamic cone-beam computed tomography (CBCT) can capture high-spatial-resolution, time-varying images for motion monitoring, patient setup, and adaptive planning of radiotherapy.
However, dynamic CBCT reconstruction is an extremely ill-posed spatiotemporal inverse problem, as each CBCT volume in the dynamic sequence is only captured by one or a few x-ray projections, due to the slow gantry rotation speed and the fast anatomical motion (e.
g.
breathing).
Approach.
We developed a machine learning-based technique, prior-model-free spatiotemporal implicit neural representation (PMF-STINR), to reconstruct dynamic CBCTs from sequentially acquired x-ray projections.
PMF-STINR employs a joint image reconstruction and registration approach to address the under-sampling challenge, enabling dynamic CBCT reconstruction from singular x-ray projections.
Specifically, PMF-STINR uses spatial implicit neural representations to reconstruct a reference CBCT volume, and it applies temporal INR to represent the intra-scan dynamic motion of the reference CBCT to yield dynamic CBCTs.
PMF-STINR couples the temporal INR with a learning-based B-spline motion model to capture time-varying deformable motion during the reconstruction.
Compared with the previous methods, the spatial INR, the temporal INR, and the B-spline model of PMF-STINR are all learned on the fly during reconstruction in a one-shot fashion, without using any patient-specific prior knowledge or motion sorting/binning.
Main results.
PMF-STINR was evaluated via digital phantom simulations, physical phantom measurements, and a multi-institutional patient dataset featuring various imaging protocols (half-fan/full-fan, full sampling/sparse sampling, different energy and mAs settings, etc).
The results showed that the one-shot learning-based PMF-STINR can accurately and robustly reconstruct dynamic CBCTs and capture highly irregular motion with high temporal (∼ 0.
1 s) resolution and sub-millimeter accuracy.
Significance.
PMF-STINR can reconstruct dynamic CBCTs and solve the intra-scan motion from conventional 3D CBCT scans without using any prior anatomical/motion model or motion sorting/binning.
It can be a promising tool for motion management by offering richer motion information than traditional 4D-CBCTs.
Related Results
Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
Radiographic imaging of the mandibular third molar (M3) is a valuable diagnostic tool. It provides information on tooth position, root morphology, and relations to surrounding anat...
Barriers Toward Better CBCT Knowledge, Attitude, and Practice
Barriers Toward Better CBCT Knowledge, Attitude, and Practice
Objective: This study attempts to evaluate the knowledge, attitude, and clinical practice of Iraqi dentists toward CBCT use, referral patterns, observed challenges, and the impacts...
Trends in CBCT current practice within three UK paediatric dental departments
Trends in CBCT current practice within three UK paediatric dental departments
Abstract
Introduction
Cone beam computed tomography (CBCT) is used across all dental specialties and has a number of advantages compared to 2D images. The SEDENTEXCT guidelines pro...
Inclination of maxillary
and mandibular incisors –
comparison of measurements
from teleroentgenograms and
CBCT
Inclination of maxillary
and mandibular incisors –
comparison of measurements
from teleroentgenograms and
CBCT
The assessment of incisor location in lateral cephalograms
is a standard strategy in orthodontic diagnostics. However,
determination of reference points on apices of roots of
incis...
Immunophenotypic changes in NRBCs of Philadelphia chromosome-negative myeloproliferative neoplasms and its clinical significance
Immunophenotypic changes in NRBCs of Philadelphia chromosome-negative myeloproliferative neoplasms and its clinical significance
Abstract
Purpose: Philadelphia chromosome-negative myeloproliferative neoplasms (MPNs) are challenging to differentiate in the early stages. Chronic inflammation and altera...
Informativeness of Cone Beam Computed Tomography in the Visualization of Injuries of Teeth and Facial Bones
Informativeness of Cone Beam Computed Tomography in the Visualization of Injuries of Teeth and Facial Bones
Introduction. Today, maxillofacial injuries (MFIs) remain a medical and social problem with an increasing frequency. Every year, a significant number of people receive facial injur...
Diagnostic efficacy of cone beam computed tomography in paediatric dentistry: a systematic review
Diagnostic efficacy of cone beam computed tomography in paediatric dentistry: a systematic review
AbstractPurposeTo determine in which clinical situations it is indicated or contra-indicated to prescribe cone beam computed tomography (CBCT) for paediatric patients.MethodsSystem...
Characterizing spatiotemporal population receptive fields in human visual cortex with fMRI
Characterizing spatiotemporal population receptive fields in human visual cortex with fMRI
AbstractThe use of fMRI and computational modeling has advanced understanding of spatial characteristics of population receptive fields (pRFs) in human visual cortex. However, we k...