Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Influence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution.

View through CrossRef
Objectives: This study compared the influence of occlusal anatomy on acrylic CAD/CAM crowns fracture load and stress distribution. The null hypothesis was that there would be no difference between the provisional crowns fracture load and stress according to different occlusal anatomy.Methods: A full-crown preparation was simulated using dentin analogue (G10, Protec, São Paulo, Brazil) totaling 20 identical preparations. Next, twenty acrylic crowns were milled using different occlusal design parameter (Young or Adult) available in the software database. The crowns were cemented (Temp-bond, NE Kerr Dental, Brea, CA, USA) and fractured using a compressive load (0.5 mm/min of cross-head speed). Data were analyzed by using one-way ANOVA and Tukey tests (p< 0.05). A similar geometry was modeled and exported to the analysis software to perform a static structural analysis. The maximum principal stress was calculated using the finite element method with 300 N chewing load simulation.Results: The occlusal anatomy significantly influenced the load-to-fracture (p<0.05). Young design showed lower fracture load (1139±132 N) than Adult design (2007±345 N). The tensile stress distribution showed a similar pattern for both groups however the highest stress peak was calculated for Young design (76 MPa) in the occlusal surface.Conclusion: The anatomy design with higher cusp angulation and occlusal sulcus more evident can increase the stress concentration and reduce the fracture load for acrylic resin CAD/CAM crowns.
Title: Influence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution.
Description:
Objectives: This study compared the influence of occlusal anatomy on acrylic CAD/CAM crowns fracture load and stress distribution.
The null hypothesis was that there would be no difference between the provisional crowns fracture load and stress according to different occlusal anatomy.
Methods: A full-crown preparation was simulated using dentin analogue (G10, Protec, São Paulo, Brazil) totaling 20 identical preparations.
Next, twenty acrylic crowns were milled using different occlusal design parameter (Young or Adult) available in the software database.
The crowns were cemented (Temp-bond, NE Kerr Dental, Brea, CA, USA) and fractured using a compressive load (0.
5 mm/min of cross-head speed).
Data were analyzed by using one-way ANOVA and Tukey tests (p< 0.
05).
A similar geometry was modeled and exported to the analysis software to perform a static structural analysis.
The maximum principal stress was calculated using the finite element method with 300 N chewing load simulation.
Results: The occlusal anatomy significantly influenced the load-to-fracture (p<0.
05).
Young design showed lower fracture load (1139±132 N) than Adult design (2007±345 N).
The tensile stress distribution showed a similar pattern for both groups however the highest stress peak was calculated for Young design (76 MPa) in the occlusal surface.
Conclusion: The anatomy design with higher cusp angulation and occlusal sulcus more evident can increase the stress concentration and reduce the fracture load for acrylic resin CAD/CAM crowns.

Related Results

Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Objectives: Dental crown clinical longevity mainly depends on how materials resist wear and maintain their surface quality. Three-Dimensionally (3D) printed resin-based crowns and ...
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cement...
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Objective: To compare fracture strength of screw-retained implant-supported crown of resin matrix ceramic when fabricated using CAD/CAM and 3D printing Material and method: vericom...
Influence of Thickness and Surface Conditioning on Fracture Resistance of Occlusal Veneer
Influence of Thickness and Surface Conditioning on Fracture Resistance of Occlusal Veneer
Abstract Background: The purpose of the current study was to assess the impact of restoration thickness, surface conditioning and the interaction between them on the fractu...
Evolution and significance of CaM KMT- Calmodulin interaction- A journey of more than 40 years
Evolution and significance of CaM KMT- Calmodulin interaction- A journey of more than 40 years
The calmodulin (CaM) family serves as the primary calcium sensor. Upon receiving calcium signals, CaM binds calcium ions and regulates the activity of numerous effector proteins. I...

Back to Top