Javascript must be enabled to continue!
Influence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution.
View through CrossRef
Objectives: This study compared the influence of occlusal anatomy on acrylic CAD/CAM crowns fracture load and stress distribution. The null hypothesis was that there would be no difference between the provisional crowns fracture load and stress according to different occlusal anatomy.Methods: A full-crown preparation was simulated using dentin analogue (G10, Protec, São Paulo, Brazil) totaling 20 identical preparations. Next, twenty acrylic crowns were milled using different occlusal design parameter (Young or Adult) available in the software database. The crowns were cemented (Temp-bond, NE Kerr Dental, Brea, CA, USA) and fractured using a compressive load (0.5 mm/min of cross-head speed). Data were analyzed by using one-way ANOVA and Tukey tests (p< 0.05). A similar geometry was modeled and exported to the analysis software to perform a static structural analysis. The maximum principal stress was calculated using the finite element method with 300 N chewing load simulation.Results: The occlusal anatomy significantly influenced the load-to-fracture (p<0.05). Young design showed lower fracture load (1139±132 N) than Adult design (2007±345 N). The tensile stress distribution showed a similar pattern for both groups however the highest stress peak was calculated for Young design (76 MPa) in the occlusal surface.Conclusion: The anatomy design with higher cusp angulation and occlusal sulcus more evident can increase the stress concentration and reduce the fracture load for acrylic resin CAD/CAM crowns.
University Library System, University of Pittsburgh
Title: Influence of occlusal anatomy on acrylic resin CAD/CAM crowns fracture load and stress distribution.
Description:
Objectives: This study compared the influence of occlusal anatomy on acrylic CAD/CAM crowns fracture load and stress distribution.
The null hypothesis was that there would be no difference between the provisional crowns fracture load and stress according to different occlusal anatomy.
Methods: A full-crown preparation was simulated using dentin analogue (G10, Protec, São Paulo, Brazil) totaling 20 identical preparations.
Next, twenty acrylic crowns were milled using different occlusal design parameter (Young or Adult) available in the software database.
The crowns were cemented (Temp-bond, NE Kerr Dental, Brea, CA, USA) and fractured using a compressive load (0.
5 mm/min of cross-head speed).
Data were analyzed by using one-way ANOVA and Tukey tests (p< 0.
05).
A similar geometry was modeled and exported to the analysis software to perform a static structural analysis.
The maximum principal stress was calculated using the finite element method with 300 N chewing load simulation.
Results: The occlusal anatomy significantly influenced the load-to-fracture (p<0.
05).
Young design showed lower fracture load (1139±132 N) than Adult design (2007±345 N).
The tensile stress distribution showed a similar pattern for both groups however the highest stress peak was calculated for Young design (76 MPa) in the occlusal surface.
Conclusion: The anatomy design with higher cusp angulation and occlusal sulcus more evident can increase the stress concentration and reduce the fracture load for acrylic resin CAD/CAM crowns.
Related Results
Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Comparative In vitro Analysis of Characteristics Between CAD-CAM Fabricated Ceramic Crowns and 3D-Printed Resin-Based Dental Crowns
Objectives: Dental crown clinical longevity mainly depends on how materials resist wear and maintain their surface quality. Three-Dimensionally (3D) printed resin-based crowns and ...
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Comparing the Repair of Veneered Zirconia Crowns with Ceramic or Composite Resin: An in Vitro Study
Statement of problem: Current techniques for repairing porcelain-chipped restorations have several limitations. With advances in CAD/CAM technology, the combination of resin cement...
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Comparative Evaluation of Fracture Strength of Implant Supported Crown Fabricated from CAD/CAM and 3D Printed Resin Matrix Ceramic
Objective: To compare fracture strength of screw-retained implant-supported crown of resin matrix ceramic when fabricated using CAD/CAM and 3D printing Material and method: vericom...
CAD‐CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study
CAD‐CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study
AbstractObjectiveTo evaluate the volumetric changes on occlusal surface of computer‐aided design and computer‐aided manufacturing (CAD‐CAM) occlusal devices fabricated following a ...
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Fracture Modelling Using Seismic Based Fracture Intensity Volume, a Case Study in Middle East
Abstract
In this paper, a case study in a fractured carbonate reservoir is presented to demonstrate the approach of fracture modeling using fracture intensity vol...
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Abstract
Background
Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK)...
The accuracy of anatomic landmarks on the occlusal plane: a comparative study between conventional and 3D image method
The accuracy of anatomic landmarks on the occlusal plane: a comparative study between conventional and 3D image method
Abstract
Background
To establish the occlusal plane, the conventional methods for facial analysis to gain accurate alignment of the occlusal plane a...
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
Effect of Milling Protocols on Trueness and Precision of Ceramic Crowns
AbstractPurposeTo investigate the effect of different milling protocols for different ceramic materials on the trueness and precision of milled ceramic crowns.Materials and Methods...