Javascript must be enabled to continue!
Correlation and clinical significance of placental tissue selectin (E), angiotensin II and its receptors, and oxidized lipid levels in patients with preeclampsia
View through CrossRef
Background: The purpose was to analyze the levels of placental tissue selectins (E), angiotensin II (AngII) and its receptors (ATRs), and oxidized lipids (malondialdehyde (MDA), 8-isoprostane 2a) in patients with preeclampsia (PE). (8-iso-PGF2a)) correlation and clinical significance. Methods: Select 30 PE pregnant women who were admitted to our hospital from March 2023 to January 2024 as the case group, and select another 30 normal pregnant women who were registered in our hospital during the same period as the health group .The general information of the two groups and placental tissue selectin (E), plasma AngII, ATRs, placental tissue MDA, 8-iso-PGF2a and blood pressure levels (systolic blood pressure (SBP), diastolic blood pressure (DBP)) were compared. Pearson correlation was used to analyze the correlation between the expression of selectin (E), AngII, ATRs, MDA, 8-iso-PGF2a and the levels of SBP and DBP. ROC curves were drawn to analyze the value of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a individually and jointly in predicting the risk of PE. Results: The expression of placental tissue selectin (E), AngII, ATRs, MDA, 8-iso-PGF2a and the levels of SBP and DBP in the case group were higher than those in the healthy group (P<0.05). Pearson correlation showed that the expression levels of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a were positively correlated with SBP and DBP (r>0, P<0.05). The results of drawing the ROC curve showed that the AUCs of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a expression in predicting the occurrence of PE were 0.854, 0.756, 0.745, 0.885, 0.900, and 0.905 respectively. Conclusions: Placenta tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a are highly expressed in pregnant women with PE. The expression of the above indicators is related to maternal blood pressure levels, and their combination can effectively increase predictive value of the risk of PE.
Centre for Evaluation in Education and Science (CEON/CEES)
Title: Correlation and clinical significance of placental tissue selectin (E), angiotensin II and its receptors, and oxidized lipid levels in patients with preeclampsia
Description:
Background: The purpose was to analyze the levels of placental tissue selectins (E), angiotensin II (AngII) and its receptors (ATRs), and oxidized lipids (malondialdehyde (MDA), 8-isoprostane 2a) in patients with preeclampsia (PE).
(8-iso-PGF2a)) correlation and clinical significance.
Methods: Select 30 PE pregnant women who were admitted to our hospital from March 2023 to January 2024 as the case group, and select another 30 normal pregnant women who were registered in our hospital during the same period as the health group .
The general information of the two groups and placental tissue selectin (E), plasma AngII, ATRs, placental tissue MDA, 8-iso-PGF2a and blood pressure levels (systolic blood pressure (SBP), diastolic blood pressure (DBP)) were compared.
Pearson correlation was used to analyze the correlation between the expression of selectin (E), AngII, ATRs, MDA, 8-iso-PGF2a and the levels of SBP and DBP.
ROC curves were drawn to analyze the value of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a individually and jointly in predicting the risk of PE.
Results: The expression of placental tissue selectin (E), AngII, ATRs, MDA, 8-iso-PGF2a and the levels of SBP and DBP in the case group were higher than those in the healthy group (P<0.
05).
Pearson correlation showed that the expression levels of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a were positively correlated with SBP and DBP (r>0, P<0.
05).
The results of drawing the ROC curve showed that the AUCs of placental tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a expression in predicting the occurrence of PE were 0.
854, 0.
756, 0.
745, 0.
885, 0.
900, and 0.
905 respectively.
Conclusions: Placenta tissue selectin (E), AngII, ATRs, MDA, and 8-iso-PGF2a are highly expressed in pregnant women with PE.
The expression of the above indicators is related to maternal blood pressure levels, and their combination can effectively increase predictive value of the risk of PE.
Related Results
Soluble l‐Selectin as an Independent Biomarker of Bronchial Asthma
Soluble l‐Selectin as an Independent Biomarker of Bronchial Asthma
BackgroundWe sought to determine the association of plasma level of soluble l‐selectin (sL‐selectin) and F206L polymorphism of l‐selectin with asthma.MethodsA total of 90 asthmatic...
Development of angiotensin (1‐7) as an agent to accelerate dermal repair
Development of angiotensin (1‐7) as an agent to accelerate dermal repair
Angiotensin II has been shown to be a potent agent in the acceleration of wound repair. Angiotensin (1‐7), a fragment of angiotensin II that is not hypertensive, was found to be co...
P-Selectin, and Not E-Selectin, Negatively Regulates Murine Megakaryocytopoiesis
P-Selectin, and Not E-Selectin, Negatively Regulates Murine Megakaryocytopoiesis
Abstract
To assess the role of P-selectin and E-selectin in megakaryocytopoiesis, in vitro assays were performed in animal models deficient in both adhesion receptor...
COURSE PREGNANCY AND ITS OUTCOME IN WOMEN AT THE HIGH RISK GROUP FOR PREECLAMPSIA
COURSE PREGNANCY AND ITS OUTCOME IN WOMEN AT THE HIGH RISK GROUP FOR PREECLAMPSIA
Introduction. Preeclampsia constitutes a significant proportion of maternal and prenatal morbidity and mortality. The rate of prenatal mortality in severe preeclampsia is 18-30 ‰, ...
Abstract 125: Modified Angiotensin II Has Lower Vasoconstrictive Effect Than Angiotensin II
Abstract 125: Modified Angiotensin II Has Lower Vasoconstrictive Effect Than Angiotensin II
Introduction:
The renin-angiotensin-aldosterone system (RAAS) is involved in the regulation of the blood pressure, water- and electrolyte balance. Pathophysiologically,...
Genetic Risk Factors Associated With Preeclampsia and Hypertensive Disorders of Pregnancy
Genetic Risk Factors Associated With Preeclampsia and Hypertensive Disorders of Pregnancy
ImportanceA genetic contribution to preeclampsia susceptibility has been established but is still incompletely understood.ObjectiveTo disentangle the underlying genetic architectur...
Comparison of L‐selectin blood level and gene polymorphism in tuberculosis patients with healthy individuals
Comparison of L‐selectin blood level and gene polymorphism in tuberculosis patients with healthy individuals
BackgroundThe inflammatory response to Mycobacterium tuberculosis bacilli influences tuberculosis (TB) progression. In this study, we aimed to identify the Phe206Leu polymorphism a...

