Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS

View through CrossRef
<div class="section abstract"> <div class="htmlview paragraph">This specification describes a method and acceptance criteria for testing automotive wire harness retainer clips. Retainer clips are plastic parts that hold a wire harness or electrical connector in a specific position. Typical plastic retainers work by having a set of “branches” that can be inserted into a hole sized to be easy to install but provide acceptable retention. This specification tests retainer clips for mechanical retention when exposed to the mechanical and environmental stresses typically found in automotive applications over a 15-year service life. This specification has several test options to allow the test to match to the expected service conditions. The variability of applications typically arises a) from different ambient temperatures near the clip, different proximity to automotive fluids, different exposure to standing water or water spray and different thicknesses of the holes that the clip is inserted into. Clips are typically inserted into sheet or rolled metal from 0.6mm to 8mm thick so this specification focuses on that range. Outside of this range requires a custom test.</div> <div class="htmlview paragraph">The procedures described in this document have been evaluated for the design types shown in <span class="xref">Table 2.3</span>. Use of USCAR-44 for other than a design shown in <span class="xref">Table 2.3</span> may or may not produce acceptable test correlation to actual experience but USCAR has not reviewed any data. USCAR-44 can be used at all phases of development, production, and field analysis since it is a performance test and not a process validation or quality assessment.</div> <div class="htmlview paragraph">No retainer may be represented as having met USCAR/EWCAP specifications unless conformance to all applicable requirements of this specification have been verified and documented. All required verification and documentation must be provided by the supplier of the part. If testing is performed by another source, it does not relieve the primary supplier of responsibility for documentation (DVP&amp;R) of all test results and for verification that all samples tested met all applicable acceptance criteria.</div></div>
SAE International
Title: PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS
Description:
<div class="section abstract"> <div class="htmlview paragraph">This specification describes a method and acceptance criteria for testing automotive wire harness retainer clips.
Retainer clips are plastic parts that hold a wire harness or electrical connector in a specific position.
Typical plastic retainers work by having a set of “branches” that can be inserted into a hole sized to be easy to install but provide acceptable retention.
This specification tests retainer clips for mechanical retention when exposed to the mechanical and environmental stresses typically found in automotive applications over a 15-year service life.
This specification has several test options to allow the test to match to the expected service conditions.
The variability of applications typically arises a) from different ambient temperatures near the clip, different proximity to automotive fluids, different exposure to standing water or water spray and different thicknesses of the holes that the clip is inserted into.
Clips are typically inserted into sheet or rolled metal from 0.
6mm to 8mm thick so this specification focuses on that range.
Outside of this range requires a custom test.
</div> <div class="htmlview paragraph">The procedures described in this document have been evaluated for the design types shown in <span class="xref">Table 2.
3</span>.
Use of USCAR-44 for other than a design shown in <span class="xref">Table 2.
3</span> may or may not produce acceptable test correlation to actual experience but USCAR has not reviewed any data.
USCAR-44 can be used at all phases of development, production, and field analysis since it is a performance test and not a process validation or quality assessment.
</div> <div class="htmlview paragraph">No retainer may be represented as having met USCAR/EWCAP specifications unless conformance to all applicable requirements of this specification have been verified and documented.
All required verification and documentation must be provided by the supplier of the part.
If testing is performed by another source, it does not relieve the primary supplier of responsibility for documentation (DVP&amp;R) of all test results and for verification that all samples tested met all applicable acceptance criteria.
</div></div>.

Related Results

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS
PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS
<div class="section abstract"> <div class="htmlview paragraph">This specification describes a method and acceptance criteria for testing automotive wire harness retai...
PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS
PERFORMANCE SPECIFICATION FOR AUTOMOTIVE WIRE HARNESS RETAINER CLIPS
<div class="section abstract"> <div class="htmlview paragraph">This specification describes a method and acceptance criteria for testing automotive wire harness retai...
A SURVEY OF RETENTION PROTOCOLS AND TRENDS PRACTICED BY ORTHODONTISTS FROM CENTRAL INDIA: AN OBSERVATIONAL STUDY
A SURVEY OF RETENTION PROTOCOLS AND TRENDS PRACTICED BY ORTHODONTISTS FROM CENTRAL INDIA: AN OBSERVATIONAL STUDY
Introduction: Retention is necessary following orthodontic treatment to prevent relapse of the final occlusal outcome. So the aim of the study is to evaluate retention procedures a...
Exploring Genre-Specific Thought Patterns Through Real-Time Experience Sampling of Movie Clips
Exploring Genre-Specific Thought Patterns Through Real-Time Experience Sampling of Movie Clips
Understanding cognition during media consumption is crucial to understanding how individuals process complex stimuli in everyday life. This study employed multi-dimensional Experie...
Polymer versus Titanium Clips in Laparoscopic Cholecystectomy
Polymer versus Titanium Clips in Laparoscopic Cholecystectomy
Background: Surgical clips are commonly used during laparoscopic cholecystectomy for cystic duct and artery ligation. Titanium and polymer clips are the two most common types used ...
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
With preheating wire by resistance heat, laser hot wire welding improves process stability and wire deposition efficiency, which gives broad potential applications in surfacing and...
Hem-o-lok clips are safe and efficacious for laparoscopic cholecystectomy: Preliminary results of a single center experience
Hem-o-lok clips are safe and efficacious for laparoscopic cholecystectomy: Preliminary results of a single center experience
Introduction: The aim of this retrospective study was to compare the outcomes after laparoscopic cholecystectomy using titanium clips or Hem-o-lok polymeric clips to close cystic a...
The Wire Harness
The Wire Harness
Abstract This chapter describes a “wire harness,” which performs the power distribution function in a vehicle electrical system. The wire harness consists of wires, conne...

Back to Top