Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Interventional therapy study on using micro-catheter joint with guide wire private for occlusion in coronary artery chronic total occlusion

View through CrossRef
Objective To evaluate the feasibility and safety of using micro-catheter joint with occlusion private guide wire for patients with coronary artery chronic total occlusion (CTO) intervention. Method Twelve patients were diagnosis as coronary CTO by radial artery angiography, and the disease itself or the opposite side had coronary collateral circulations. Prorsad posted in soft guide wire to the proximal occlusion, extended the soft guide wire, then posted in micro-catheter to the proximal occlusion and withdrawed the soft guide wire. Using micro-catheter to change different CTO special guide wires, fine controlled guide wire direction, adjusted the guide wire head-end hardness and then did highly selective angiography by micro-catheter. After the occlusion, did balloon dilatation and stenting. Results Eleven cases were successful to do percutaneous transluminal coronary angioplasty (PTCA) and stenting, and one case was failed. Intraoperative, there were no complications both coronary artery dissection and perforation. Conclusion Using micro-catheter joint with guide wire private for occlusion, is a safe and effective method in coronary artery CTO intervention.
Title: Interventional therapy study on using micro-catheter joint with guide wire private for occlusion in coronary artery chronic total occlusion
Description:
Objective To evaluate the feasibility and safety of using micro-catheter joint with occlusion private guide wire for patients with coronary artery chronic total occlusion (CTO) intervention.
Method Twelve patients were diagnosis as coronary CTO by radial artery angiography, and the disease itself or the opposite side had coronary collateral circulations.
Prorsad posted in soft guide wire to the proximal occlusion, extended the soft guide wire, then posted in micro-catheter to the proximal occlusion and withdrawed the soft guide wire.
Using micro-catheter to change different CTO special guide wires, fine controlled guide wire direction, adjusted the guide wire head-end hardness and then did highly selective angiography by micro-catheter.
After the occlusion, did balloon dilatation and stenting.
Results Eleven cases were successful to do percutaneous transluminal coronary angioplasty (PTCA) and stenting, and one case was failed.
Intraoperative, there were no complications both coronary artery dissection and perforation.
Conclusion Using micro-catheter joint with guide wire private for occlusion, is a safe and effective method in coronary artery CTO intervention.

Related Results

Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
A study on risk factors of coronary artery disease in Chong Qing city
A study on risk factors of coronary artery disease in Chong Qing city
Objective To investigate the relationship between risk factors and coronary artery disease in Chong Qing city, and to provide scientific basis for preventing and ...
The effects of transcatheter closure of coronary-pulmonary arterial fistulas in adults
The effects of transcatheter closure of coronary-pulmonary arterial fistulas in adults
Objective Congenital coronary artery fistula (CAF) is an extremely rare congenital anomaly of the coronary artery. We report our experience with Tran catheter occ...
Preliminary experience with 5 and 6 french diagnostic catheters as guiding catheters for coronary angioplasty
Preliminary experience with 5 and 6 french diagnostic catheters as guiding catheters for coronary angioplasty
AbstractWith the reduction in profile of balloon dilation catheters, until recently, it has been the internal dimensions and performance of the guiding catheter that has mandated t...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

Back to Top