Javascript must be enabled to continue!
Renal puncture access using a blunt needle: proposal of the blunt puncture concept
View through CrossRef
Abstract
Purpose
Severe haemorrhage in percutaneous nephrolithotomy (PCNL) is an alarming event, and preventing injury to renal major vessels is a challenge. We evaluated the efficiency of a blunt needle in renal puncture procedures.
Methods
We first retrospectively reviewed the embolization images of post-PCNL patients to analyse the types of arteries injured, which were considered target arteries. Then, either a blunt needle or a conventional needle was used to directly puncture target arteries in ex vivo porcine kidneys and to establish renal access ex vivo and in vivo. The primary outcome was the incidence of target artery injuries, which were observed by digital subtraction angiography, nephroscopy and 3-dimensional endocasts. The secondary outcome was the rate of excreted fluid per access.
Results
The segmental and interlobar arteries were the most common types of injured arteries that needed to be embolized after PCNL. When these arteries were punctured directly, blunt needles reduced injury (1/20 vs. 16/20; OR 4.750; 95% CI 1.966–11.478; P < .001) by 76% compared to injuries induced by conventional needles. Moreover, the blunt needle group also had a significantly lower incidence of these arteries’ injuries ex vivo due to renal puncture and yielded a lower rate of excreted fluid in ex vivo and in vivo renal puncture procedures.
Conclusion
A blunt needle for renal puncture can be effective in reducing injury to renal major arteries and the accompanying haemorrhage. We propose the concept of blunt puncture, which may be a promising method for achieving safe renal access in PCNL.
Springer Science and Business Media LLC
Title: Renal puncture access using a blunt needle: proposal of the blunt puncture concept
Description:
Abstract
Purpose
Severe haemorrhage in percutaneous nephrolithotomy (PCNL) is an alarming event, and preventing injury to renal major vessels is a challenge.
We evaluated the efficiency of a blunt needle in renal puncture procedures.
Methods
We first retrospectively reviewed the embolization images of post-PCNL patients to analyse the types of arteries injured, which were considered target arteries.
Then, either a blunt needle or a conventional needle was used to directly puncture target arteries in ex vivo porcine kidneys and to establish renal access ex vivo and in vivo.
The primary outcome was the incidence of target artery injuries, which were observed by digital subtraction angiography, nephroscopy and 3-dimensional endocasts.
The secondary outcome was the rate of excreted fluid per access.
Results
The segmental and interlobar arteries were the most common types of injured arteries that needed to be embolized after PCNL.
When these arteries were punctured directly, blunt needles reduced injury (1/20 vs.
16/20; OR 4.
750; 95% CI 1.
966–11.
478; P < .
001) by 76% compared to injuries induced by conventional needles.
Moreover, the blunt needle group also had a significantly lower incidence of these arteries’ injuries ex vivo due to renal puncture and yielded a lower rate of excreted fluid in ex vivo and in vivo renal puncture procedures.
Conclusion
A blunt needle for renal puncture can be effective in reducing injury to renal major arteries and the accompanying haemorrhage.
We propose the concept of blunt puncture, which may be a promising method for achieving safe renal access in PCNL.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
A 3D Printing Personalized Percutaneous Nephroscope Puncture Guide Plate in Percutaneous Nephrolithotomy: A Pilot Study
A 3D Printing Personalized Percutaneous Nephroscope Puncture Guide Plate in Percutaneous Nephrolithotomy: A Pilot Study
Abstract
Objective Using CTU, combined with 3D printing technology, digital design, the development of individualized PCNL) puncture guides, preliminary discussion of its f...
Incidence and risk factors of Postdural Puncture Headache: Prospective cohort study design
Incidence and risk factors of Postdural Puncture Headache: Prospective cohort study design
Abstract
Background:Postdural puncture headache is one of the complications following spinal anaesthesia and accidental dural puncture. Several modifiable risk factors cont...
Incidence and risk factors of Postdural Puncture Headache: Prospective cohort study design
Incidence and risk factors of Postdural Puncture Headache: Prospective cohort study design
Abstract
Background: Post-dural puncture headache is one of the complications following spinal anaesthesia and accidental dural puncture. Several modifiable risk factors co...
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Needle consideration in umbilical two-port laparoscopic percutaneous extraperitoneal closure for patent processus vaginalis of children: hook-needle or forcep-needle
Abstract
Background
Although umbilical two-port laparoscopic percutaneous extraperitoneal closure for the treatment of processus vaginalis patency o...
Modified Ablation Catheter Guided Transseptal Puncture under ICE Guidance
Modified Ablation Catheter Guided Transseptal Puncture under ICE Guidance
Abstract
Background
Zero-fluoroscopy procedures have become increasingly popular in electrophysiological interventional surgery. As the key technology to achieve zero-fluo...
Design and Experimental Evaluation of Mosquito-Inspired Needle Structure in Soft Materials
Design and Experimental Evaluation of Mosquito-Inspired Needle Structure in Soft Materials
Abstract
Insects steer their stingers effortlessly to a specific target and release their venom in a certain path through the skin with minimal pain. These unique tr...
Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation
Semi-automatic puncture robotic system based on real-time multi-modal image fusion: preclinical evaluation
Abstract
Purpose
Traditional surgical robot system relying on computed tomography (CT) navigation suffers from two drawbacks during abdominal org...

