Javascript must be enabled to continue!
An examination of sleep spindle metrics in the Sleep Heart Health Study: superiority of automated spindle detection over total sigma power in assessing spindle activity
View through CrossRef
Abstract
Background. Sleep spindle activity is commonly estimated by measuring sigma power during stage 2 non-rapid eye movement (NREM2) sleep. However, spindles account for little of the total NREM2 interval and therefore sigma power over the entire interval may be misleading. This study compares derived spindle measures from direct automated spindle detection with those from gross power spectral analyses for the purposes of clinical trial design.Methods. We estimated spindle activity in a set of 8,440 overnight electroencephalogram (EEG) recordings from 5,793 patients from the Sleep Heart Health Study using both sigma power and direct automated spindle detection. Performance of the two methods was evaluated by ability to distinguish NREM2 from other NREM sleep stages and by determining the sample size required to detect decline in age-related spindle coherence with each method in a simulated clinical trial. Results. Mean sigma power in NREM2 was indistinguishable from other NREM states in 25% of recordings, vs only 7% for direct spindle measurement (P < 0.001). These percentages were 34% and 14% respectively for sigma coherence comparisons. In a simulated clinical trial, sigma power required a sample size of 115 to achieve 95% power to identify age-related changes in sigma coherence, while automated spindle detection required a sample size of only 60.Conclusions. Measurements of spindle activity utilizing automated spindle detection outperformed conventional sigma power analysis by a wide margin, suggesting that many studies would benefit from incorporation of automated spindle detection. These results further suggest that some previous studies which have failed to detect changes in sigma power or coherence may have failed simply because they were underpowered.
Research Square Platform LLC
Title: An examination of sleep spindle metrics in the Sleep Heart Health Study: superiority of automated spindle detection over total sigma power in assessing spindle activity
Description:
Abstract
Background.
Sleep spindle activity is commonly estimated by measuring sigma power during stage 2 non-rapid eye movement (NREM2) sleep.
However, spindles account for little of the total NREM2 interval and therefore sigma power over the entire interval may be misleading.
This study compares derived spindle measures from direct automated spindle detection with those from gross power spectral analyses for the purposes of clinical trial design.
Methods.
We estimated spindle activity in a set of 8,440 overnight electroencephalogram (EEG) recordings from 5,793 patients from the Sleep Heart Health Study using both sigma power and direct automated spindle detection.
Performance of the two methods was evaluated by ability to distinguish NREM2 from other NREM sleep stages and by determining the sample size required to detect decline in age-related spindle coherence with each method in a simulated clinical trial.
Results.
Mean sigma power in NREM2 was indistinguishable from other NREM states in 25% of recordings, vs only 7% for direct spindle measurement (P < 0.
001).
These percentages were 34% and 14% respectively for sigma coherence comparisons.
In a simulated clinical trial, sigma power required a sample size of 115 to achieve 95% power to identify age-related changes in sigma coherence, while automated spindle detection required a sample size of only 60.
Conclusions.
Measurements of spindle activity utilizing automated spindle detection outperformed conventional sigma power analysis by a wide margin, suggesting that many studies would benefit from incorporation of automated spindle detection.
These results further suggest that some previous studies which have failed to detect changes in sigma power or coherence may have failed simply because they were underpowered.
Related Results
L᾽«unilinguisme» officiel de Constantinople byzantine (VIIe-XIIe s.)
L᾽«unilinguisme» officiel de Constantinople byzantine (VIIe-XIIe s.)
<p>Νίκος Οικονομίδης</...
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
North Syrian Mortaria and Other Late Roman Personal and Utility Objects Bearing Inscriptions of Good Luck
<span style="font-size: 11pt; color: black; font-family: 'Times New Roman','serif'">ΠΗΛΙΝΑ ΙΓ&Delta...
A Comparison of Spindle Activity Measurements: Automated Spindle Detection Helps Distinguish Changes in Spindle Activity
A Comparison of Spindle Activity Measurements: Automated Spindle Detection Helps Distinguish Changes in Spindle Activity
Abstract
Study Objectives.
Sleep spindle activity is commonly estimated by measuring sigma power during stage 2 non-rapid eye movement (NREM2) sleep. However, spindles acc...
Un manoscritto equivocato del copista santo Theophilos († 1548)
Un manoscritto equivocato del copista santo Theophilos († 1548)
<p><font size="3"><span class="A1"><span style="font-family: 'Times New Roman','serif'">ΕΝΑ ΛΑΝ&...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Functoriality of the Schmidt Construction
Functoriality of the Schmidt Construction
After proving, in a purely categorial way, that the inclusion functor InAlg(Σ) from Alg(Σ), the category of many-sorted Σ-algebras, to PAlg(&Sigma...
Nurse-delivered sleep restriction therapy to improve insomnia disorder in primary care: the HABIT RCT
Nurse-delivered sleep restriction therapy to improve insomnia disorder in primary care: the HABIT RCT
Background
Insomnia is a prevalent and distressing sleep disorder. Multicomponent cognitive–behavioural therapy is the recommended first-line treatment, but access remains extremel...
0864 Severe Central Sleep Apnea
0864 Severe Central Sleep Apnea
Abstract
Introduction
Central sleep apnea (CSA) is a rare form of sleep disordered breathing with repeated apneic episodes with ...

