Javascript must be enabled to continue!
Exploiting Zeta potential of air borne pathogenic bacteria for effective air decontamination
View through CrossRef
AbstractBackgroundAirborne microorganisms contribute significantly to hospital-associated infections (HAIs), particularly causing respiratory tract infections (RTIs). Multi-drug resistant (MDR) airborne pathogens pose a global clinical threat, challenging existing air decontamination technologies. While current methods effectively trap microbes, they often lack microbicidal properties. Exploitation of Zeta potential of microbes which are naturally charged could be a potential strategy for air decontamination, independent of their antimicrobial resistance. In this study, we tested the efficacy of ZeBox technology which relies on zeta potential to trap and eliminate airborne pathogens such as clinically isolated, MDRKlebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Escherichia coliof respiratory origin and a non RTI isolateStaphylococcus aureus.MethodsFive MDR bacterial pathogens which includeK. pneumoniae(2 nos),A. baumannii, P. aeruginosa, andE. colifrom patients with RTI and one pus isolate ofS. aureuswere included in the study. These isolates were aerosolized in a certified BSL-2 setting containing a ZeBox-powered Air Sterilization device. Viable bacteria were enumerated before and after exposure to the Zebox powered device. Clinical and laboratory isolated bacterial strains were assessed for zeta potential variations to understand its association with antibiotic resistance and pathogenicity.ResultsOur analyses revealed that Zeta potential is species specific, but independent of the pathogenicity and antibiotic susceptibility of the tested bacteria. Exposure to Zebox powered device for 5 mins resulted in a remarkable decline of microbial load with a minimum 5 log reduction (99.999%) of all the tested isolates, irrespective of their species. Zeta potential measurements further indicated a consistent killing mechanism of MDR pathogens by Zebox technology.ConclusionsThe current study underscores the reliability of zeta potential based air decontamination strategies for potential elimination of diverse, air borne MDR bacteria in healthcare settings.HighlightsZeta potential value of bacteria is not influenced by AST or pathogenicity of bacteria.Zeta potential driven device traps and kills airborne MDR bacteria with 99.999% efficiency.The efficacy of ZeBox technology is consistent across pathogens.
Cold Spring Harbor Laboratory
Title: Exploiting Zeta potential of air borne pathogenic bacteria for effective air decontamination
Description:
AbstractBackgroundAirborne microorganisms contribute significantly to hospital-associated infections (HAIs), particularly causing respiratory tract infections (RTIs).
Multi-drug resistant (MDR) airborne pathogens pose a global clinical threat, challenging existing air decontamination technologies.
While current methods effectively trap microbes, they often lack microbicidal properties.
Exploitation of Zeta potential of microbes which are naturally charged could be a potential strategy for air decontamination, independent of their antimicrobial resistance.
In this study, we tested the efficacy of ZeBox technology which relies on zeta potential to trap and eliminate airborne pathogens such as clinically isolated, MDRKlebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, Escherichia coliof respiratory origin and a non RTI isolateStaphylococcus aureus.
MethodsFive MDR bacterial pathogens which includeK.
pneumoniae(2 nos),A.
baumannii, P.
aeruginosa, andE.
colifrom patients with RTI and one pus isolate ofS.
aureuswere included in the study.
These isolates were aerosolized in a certified BSL-2 setting containing a ZeBox-powered Air Sterilization device.
Viable bacteria were enumerated before and after exposure to the Zebox powered device.
Clinical and laboratory isolated bacterial strains were assessed for zeta potential variations to understand its association with antibiotic resistance and pathogenicity.
ResultsOur analyses revealed that Zeta potential is species specific, but independent of the pathogenicity and antibiotic susceptibility of the tested bacteria.
Exposure to Zebox powered device for 5 mins resulted in a remarkable decline of microbial load with a minimum 5 log reduction (99.
999%) of all the tested isolates, irrespective of their species.
Zeta potential measurements further indicated a consistent killing mechanism of MDR pathogens by Zebox technology.
ConclusionsThe current study underscores the reliability of zeta potential based air decontamination strategies for potential elimination of diverse, air borne MDR bacteria in healthcare settings.
HighlightsZeta potential value of bacteria is not influenced by AST or pathogenicity of bacteria.
Zeta potential driven device traps and kills airborne MDR bacteria with 99.
999% efficiency.
The efficacy of ZeBox technology is consistent across pathogens.
Related Results
Dry versus wet decontamination in disaster medicine: a focused review
Dry versus wet decontamination in disaster medicine: a focused review
Background: A key component of disaster preparedness and response is efficient decontamination, especially in situations involving mass casualties and chemical, biological, radiolo...
European survey on decontamination in mass casualty incidents
European survey on decontamination in mass casualty incidents
Objective: The goal of this study is to assess the European status in the case of mass casualties regarding legislation, responsibilities of ministries and organizations, education...
Socio-Demographic and Eco-Epidemiological Parameters of Tick-Borne Infections Morbidity in Baikal Region
Socio-Demographic and Eco-Epidemiological Parameters of Tick-Borne Infections Morbidity in Baikal Region
The aim of the work was to compare the main socio-demographic and eco-epidemiological parameters of tick-borne viral encephalitis, tick-borne borrelioses and tick-borne rickettsios...
Emergency responders’ experiences of and expectations regarding decontamination
Emergency responders’ experiences of and expectations regarding decontamination
Purpose– There is an assumption in emergency planning that the public will “panic” or refuse to comply in the event of mass decontamination. This assumption has serious implication...
Myocardial performance index in fetal anemia
Myocardial performance index in fetal anemia
AbstractObjectiveThe objective of the study was to examine the correlation between fetal myocardial performance index (MPI) and hemoglobin (Hb) levels.MethodsIt is a prospective st...
Whole Exome Sequencing and Extended Thrombophilia Testing in Patients with Venous Thromboembolism
Whole Exome Sequencing and Extended Thrombophilia Testing in Patients with Venous Thromboembolism
Abstract
Introduction: Venous thromboembolism (VTE), defined as deep venous thrombosis (DVT) and pulmonary embolism (PE), is a cause of significant morbidity and mor...
Effect of Gram-positive bacteria on antibiotic resistance in Gram-negative bacteria
Effect of Gram-positive bacteria on antibiotic resistance in Gram-negative bacteria
Antibiotics are one of the most common treatments for bacterial infections, but the emergence of antibiotic resistance is a major threat to the control of infectious diseases. Many...
Distribution of pathogenic bacteria and antimicrobial sensitivity of eye infections in Suzhou
Distribution of pathogenic bacteria and antimicrobial sensitivity of eye infections in Suzhou
AIM: To investigate the types of bacteria in patients with eye infections in Suzhou and their drug resistance to commonly used antibacterial drugs.
METHODS: The clinical data of 15...