Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Thermal Influence on the LRI Scale Factor

View through CrossRef
<p>In this talk we present the current status of our investigations regarding variations of the LRI scale factor with spotlight on the thermal environment of the LRI. Furthermore, we describe an alternative derivation of the scale factor through LRI telemetry data.</p><p>In the current SDS processing scheme for deriving the LRI scale factor, a cross-calibration to the KBR range is employed, which numerically estimates the LRI scale and a time-tag offset by minimizing the difference between KBR and LRI range. Typical numerical values are in the order of 2.2*10<sup>-6</sup> for the scale and a few tens of microseconds for the time-tag offset. The scale shows some recurring features on large time scales, which we were investigating in depth.</p><p>At first, we use a LRI telemetry based model for the nominal laser frequency (see https://doi.org/10.5194/egusphere-egu2020-15569), which already reduces the LRI scale to below ±5*10<sup>-8</sup>, but does not suppress the features occurring on a 3-month time scale. To address these, we investigate thermal variations of the LRI instrument and its subsystems. We do not expect the temperatures to directly influence the laser frequency, but rather assume a proportionality of temperature and phase, which would manifest in tone errors at 1 CPR and 2 CPR. With our analysis, we were able to derive linear coupling factors for mapping temperature variations to errors in the LRI ranging data. With this tone error correction applied, the difference between LRI and KBR range can be reduced by about 60% at low frerquencies. Currently, we’re investigating the influence of our correction on the 1 CPR and 2 CPR amplitudes and their differences w.r.t. the KBR range.</p><p>Our goal is to derive a model for the LRI scale factor, which uses only LRI telemetry and temperature sensors. That would be especially beneficial in case the KBR observation become unavailable in GRACE-FO, and is furthermore helpful for the design of future laser ranging instruments.</p>
Title: Thermal Influence on the LRI Scale Factor
Description:
<p>In this talk we present the current status of our investigations regarding variations of the LRI scale factor with spotlight on the thermal environment of the LRI.
Furthermore, we describe an alternative derivation of the scale factor through LRI telemetry data.
</p><p>In the current SDS processing scheme for deriving the LRI scale factor, a cross-calibration to the KBR range is employed, which numerically estimates the LRI scale and a time-tag offset by minimizing the difference between KBR and LRI range.
Typical numerical values are in the order of 2.
2*10<sup>-6</sup> for the scale and a few tens of microseconds for the time-tag offset.
The scale shows some recurring features on large time scales, which we were investigating in depth.
</p><p>At first, we use a LRI telemetry based model for the nominal laser frequency (see https://doi.
org/10.
5194/egusphere-egu2020-15569), which already reduces the LRI scale to below ±5*10<sup>-8</sup>, but does not suppress the features occurring on a 3-month time scale.
To address these, we investigate thermal variations of the LRI instrument and its subsystems.
We do not expect the temperatures to directly influence the laser frequency, but rather assume a proportionality of temperature and phase, which would manifest in tone errors at 1 CPR and 2 CPR.
With our analysis, we were able to derive linear coupling factors for mapping temperature variations to errors in the LRI ranging data.
With this tone error correction applied, the difference between LRI and KBR range can be reduced by about 60% at low frerquencies.
Currently, we’re investigating the influence of our correction on the 1 CPR and 2 CPR amplitudes and their differences w.
r.
t.
the KBR range.
</p><p>Our goal is to derive a model for the LRI scale factor, which uses only LRI telemetry and temperature sensors.
That would be especially beneficial in case the KBR observation become unavailable in GRACE-FO, and is furthermore helpful for the design of future laser ranging instruments.
</p>.

Related Results

Relative Kinematic Orbit Determination for GRACE-FO Satellite by Jointing GPS and LRI
Relative Kinematic Orbit Determination for GRACE-FO Satellite by Jointing GPS and LRI
As the first in-orbit formation satellites equipped with a Laser Ranging Interferometer (LRI) instrument, Gravity Recovery and Climate Experiment Follow-on (GRACE-FO) satellites ar...
Scale Factor Determination for the GRACE-FO LRI and Thermal Coupling in KBR-LRI Residuals
Scale Factor Determination for the GRACE-FO LRI and Thermal Coupling in KBR-LRI Residuals
<p>The GRACE-FO missions hosts two ranging instruments, namely the prime K-Band Ranging (KBR) and the Laser Ranging Interferometer (LRI) as a technology demonstrator....
Novel LRI Level 0/1A Data Simulator
Novel LRI Level 0/1A Data Simulator
GRACE-FO was launched almost six years ago, following the successful GRACE mission. Measuring changes in the Earth's mass distribution is useful for climate research, such as monit...
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements 
Near-Surface Properties of Europa Constrained by the Galileo PPR Measurements 
NASA's Europa Clipper mission will characterize the current and recent surface activity of the icy-moon Europa through a wide range of remote sensing observations. In particular, t...
Patterns in GRACE-FO LRI Post-Fit Range Rate Residuals
Patterns in GRACE-FO LRI Post-Fit Range Rate Residuals
The LRI on GRACE Follow-On (GRACE-FO) provided range and range rate measurements for more than 4 years. At our institute we produce monthly gravity field coefficients from these ob...
Management of Corneal Astigmatism by Limbal Relaxing Incisions during Phacoemulsification
Management of Corneal Astigmatism by Limbal Relaxing Incisions during Phacoemulsification
Background: Phacoemulsification is one of the most successfully and commonly performed cataract surgeries worldwide. Modern cataract and refractive surgery aims not only to improve...
Interfacial thermal conductance of gallium nitride/graphene/diamond heterostructure based on molecular dynamics simulation
Interfacial thermal conductance of gallium nitride/graphene/diamond heterostructure based on molecular dynamics simulation
<sec>Gallium nitride chips are widely used in high-frequency and high-power devices. However, thermal management is a serious challenge for gallium nitride devices. To improv...

Back to Top