Javascript must be enabled to continue!
A 3D Printing Based Anthropomorphic Eye Phantom Development
View through CrossRef
This study aimed to construct a tissue-equivalent anthropomorphic phantom using 3D printing to enable dosimetry with radiochromic films of the optical apparatus in external beam radiotherapy. Slices were developed based on and intended to be used in conjunction with the reference phantom ATOM. 3D printing with polylactic acid (PLA) was utilized to represent soft tissues, while a mixture of gypsum, salt, and water was used as a skull bone simulator. The validation of the phantom was conducted through Hounsfield Units (HU) assessments to verify the homogeneity and compatibility with the ATOM phantom. Homogeneity was confirmed with a variation of 28.1% in the PLA component and 6.6% in the gypsum mixture. The results also demonstrated compatibility with the materials of the ATOM phantom. The phantom was successfully constructed and validated, making it suitable for testing as a dosimetric system for evaluating doses in the ocular region during radiotherapeutic procedures.
Sociedade Brasileira de Proteção Radiológica - SBPR
Title: A 3D Printing Based Anthropomorphic Eye Phantom Development
Description:
This study aimed to construct a tissue-equivalent anthropomorphic phantom using 3D printing to enable dosimetry with radiochromic films of the optical apparatus in external beam radiotherapy.
Slices were developed based on and intended to be used in conjunction with the reference phantom ATOM.
3D printing with polylactic acid (PLA) was utilized to represent soft tissues, while a mixture of gypsum, salt, and water was used as a skull bone simulator.
The validation of the phantom was conducted through Hounsfield Units (HU) assessments to verify the homogeneity and compatibility with the ATOM phantom.
Homogeneity was confirmed with a variation of 28.
1% in the PLA component and 6.
6% in the gypsum mixture.
The results also demonstrated compatibility with the materials of the ATOM phantom.
The phantom was successfully constructed and validated, making it suitable for testing as a dosimetric system for evaluating doses in the ocular region during radiotherapeutic procedures.
Related Results
Rd-phantom and RD-Ext-phantom morphisms
Rd-phantom and RD-Ext-phantom morphisms
A morphism f of left R-modules is called an RD-phantom morphism if the
induced morphism Tor1(R=aR,f)=0 for any a ? R. Similarly, a morphism g
of left R-modules is said to be ...
Psihološke odrednice sindroma suhog oka
Psihološke odrednice sindroma suhog oka
Introduction: Dry eye disease (DED) is a worldwide public health problem that may cause serious consequences for the patient's health. The etiology of the disease is multifactorial...
Phantom smoking among young adult bar patrons
Phantom smoking among young adult bar patrons
Objective
To explore the prevalence and sociodemographic makeup of smokers who do not self-identify as smokers (ie, phantom smokers) compared with self-identifyin...
Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia
AIM: To investigate the incidence of preoperative dry eye and related factors in patients undergoing corneal refractive surgery to correct myopia.
METHODS: A total of 141 patients ...
Development, Construction, and Evaluation of an Alternative Dosimetry Phantom for Computed Tomography
Development, Construction, and Evaluation of an Alternative Dosimetry Phantom for Computed Tomography
This article aims to present the development, construction, and evaluation of an alternative computed tomography dose index (CTDI) phantom. Epoxy resin was mixed with an iodine-bas...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
Optimisation of screen printing process for functional printing
Optimisation of screen printing process for functional printing
PurposeThe purpose of this study is to explain the effects of screen printing parameters on the quantity of ink deposited and the print quality in the context of printing of functi...
Effectiveness of radiation shields to minimize operator dose in the bronchoscopy suite: a phantom study and clinical cases
Effectiveness of radiation shields to minimize operator dose in the bronchoscopy suite: a phantom study and clinical cases
Abstract
Background
The purpose of this study was to 1) evaluate the effectiveness of radiation shields to minimize radiation exposure to the bronchoscopist location in a ...

