Javascript must be enabled to continue!
A UNIQUOME BASED METHOD FOR THE PROTEIN IDENTIFICATION BY MASS SPECTROMETRY
View through CrossRef
Abstract
Protein identification by mass spectrometry is a pivotal step in proteomics. Numerous methods have been developed to securely and effectively identify proteins derived from experimentally detected peptides by mass spectrometry. The dominant approach is based on the assumption that each experimentally identified peptide can be matched with a peptide included in a database of peptide sequences, generated by in silico digestion of proteins with a specific proteolytic enzyme. In this way, the protein containing the peptide can be identified. In a more advanced approach, the proteins and their in silico–digested peptides in the database are transformed into theoretical mass spectrometry spectra, and search engines match the experimentally obtained spectra to these theoretical spectra generated from protein and peptide sequences. We developed an alternative method for protein identification using Core Unique Peptides (CrUPs) and the Uniquome, termed as Uniquome-Based Protein Identification Method (UB-PIM). According to this method, instead of searching for peptides in the database of in silico–digested peptides, we search for CrUPs within the experimentally obtained peptides by mass spectrometry. If a peptide contains at least one CrUP, it can be directly correlated to the protein from which the CrUP is derived. Because of the unique nature of CrUPs, peptides obtained by MS can securely and uniquely identify the protein of origin. This provides a reference space in which even single-peptide identifications can achieve high specificity, reducing the ambiguity caused by shared or homologous sequences and improving the interpretability of MS data. Furthermore, UB-PIM can be applied to any type of peptide and is effective with both Data-Independent Acquisition (DIA) and Data-Dependent Acquisition (DDA) approaches, as well as with top-down and bottom-up proteomics. This allows confident protein identification from minimal evidence, expands the scope of detectable proteins, and remains computationally efficient, rapid, and universally applicable.
Cold Spring Harbor Laboratory
Title: A UNIQUOME BASED METHOD FOR THE PROTEIN IDENTIFICATION BY MASS SPECTROMETRY
Description:
Abstract
Protein identification by mass spectrometry is a pivotal step in proteomics.
Numerous methods have been developed to securely and effectively identify proteins derived from experimentally detected peptides by mass spectrometry.
The dominant approach is based on the assumption that each experimentally identified peptide can be matched with a peptide included in a database of peptide sequences, generated by in silico digestion of proteins with a specific proteolytic enzyme.
In this way, the protein containing the peptide can be identified.
In a more advanced approach, the proteins and their in silico–digested peptides in the database are transformed into theoretical mass spectrometry spectra, and search engines match the experimentally obtained spectra to these theoretical spectra generated from protein and peptide sequences.
We developed an alternative method for protein identification using Core Unique Peptides (CrUPs) and the Uniquome, termed as Uniquome-Based Protein Identification Method (UB-PIM).
According to this method, instead of searching for peptides in the database of in silico–digested peptides, we search for CrUPs within the experimentally obtained peptides by mass spectrometry.
If a peptide contains at least one CrUP, it can be directly correlated to the protein from which the CrUP is derived.
Because of the unique nature of CrUPs, peptides obtained by MS can securely and uniquely identify the protein of origin.
This provides a reference space in which even single-peptide identifications can achieve high specificity, reducing the ambiguity caused by shared or homologous sequences and improving the interpretability of MS data.
Furthermore, UB-PIM can be applied to any type of peptide and is effective with both Data-Independent Acquisition (DIA) and Data-Dependent Acquisition (DDA) approaches, as well as with top-down and bottom-up proteomics.
This allows confident protein identification from minimal evidence, expands the scope of detectable proteins, and remains computationally efficient, rapid, and universally applicable.
Related Results
Endothelial Protein C Receptor
Endothelial Protein C Receptor
IntroductionThe protein C anticoagulant pathway plays a critical role in the negative regulation of the blood clotting response. The pathway is triggered by thrombin, which allows ...
Breast Carcinoma within Fibroadenoma: A Systematic Review
Breast Carcinoma within Fibroadenoma: A Systematic Review
Abstract
Introduction
Fibroadenoma is the most common benign breast lesion; however, it carries a potential risk of malignant transformation. This systematic review provides an ove...
MSFC: A New Feature Construction Method for Accurate Diagnosis of Mass Spectrometry Data
MSFC: A New Feature Construction Method for Accurate Diagnosis of Mass Spectrometry Data
Abstract
Background
Mass spectrometry technology can realize dynamic detection of many complex matrix samples in a simple, rapid, compassionate, precise, and high-throughp...
Desmoid-Type Fibromatosis of The Breast: A Case Series
Desmoid-Type Fibromatosis of The Breast: A Case Series
Abstract
IntroductionDesmoid-type fibromatosis (DTF), also called aggressive fibromatosis, is a rare, benign, locally aggressive condition. Mammary DTF originates from fibroblasts ...
Mass spectrometry of oligosaccharides
Mass spectrometry of oligosaccharides
Abstract
I.
Introduction
162
II.
CHARACTERISTICS OF TANDEM MASS SPECTRA OF CARBOHYDRATES
163
A. Ionization of Carbohydrates
163
1. Electrospray Ionization (E...
Identification of the ‘wrong’ active pharmaceutical ingredient in a counterfeit Halfan™ drug product using accurate mass electrospray ionisation mass spectrometry, accurate mass tandem mass spectrometry and liquid chromatography/mass spectrometry
Identification of the ‘wrong’ active pharmaceutical ingredient in a counterfeit Halfan™ drug product using accurate mass electrospray ionisation mass spectrometry, accurate mass tandem mass spectrometry and liquid chromatography/mass spectrometry
AbstractMethodology is presented for identifying an unknown active (pharmaceutical) ingredient (AI) in a counterfeit drug product. A range of mass spectrometric techniques, i.e., a...
Mass Spectrometry of Long‐Lived RadionuclidesUpdate based on the original article by J.S. Becker,Encyclopedia of Analytical Chemistry, © 2000, John Wiley & Sons, Ltd.
Mass Spectrometry of Long‐Lived RadionuclidesUpdate based on the original article by J.S. Becker,Encyclopedia of Analytical Chemistry, © 2000, John Wiley & Sons, Ltd.
AbstractInorganic mass spectrometric methods are powerful multielement analytical techniques for sensitive determination at the trace and ultratrace level, and for isotope ratio me...
Comparison of flow injection analysis electrospray mass spectrometry and tandem mass spectrometry and electrospray high‐field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry for the determination of underivatized amino acid
Comparison of flow injection analysis electrospray mass spectrometry and tandem mass spectrometry and electrospray high‐field asymmetric waveform ion mobility mass spectrometry and tandem mass spectrometry for the determination of underivatized amino acid
AbstractTwenty proteinogenic amino acids (AAs) were determined without derivatization using flow injection analysis followed by electrospray ionization mass spectrometry and tandem...

