Context: Ventilator-associated pneumonia (VAP) causes substantial morbidity and mortality. The influence of intermittent subglottic secretion drainage (SSD) in preventing VAP has been supported by literature studies.Objective: To find out the effectiveness of subglottic secretion drainage (SSD) on prevention of ventilator associated pneumonia (VAP) using endotracheal tube with subglottic secretion drainage (ETT-SSD).Methodology: This study was carried out in the 10 beded medical-care Intensive Care Unit (ICU) of BIRDEM Hospital, Dhaka over a period of one and half year, enrolling 48 subjects. Patients expected to require mechanical ventilation (MV) for more than >48 hrs were randomly assigned to one of two groups: one was ventilated with ETT-SSD and the other with conventional endotracheal tube (ETT-C).Results: Primary outcome was the overall incidence of VAP based on quantitative culture of distal pulmonary samplings performed after each clinical suspicion. Other outcomes included incidence of early and late onset VAP, duration of MV, duration of ICU stay and in hospital mortality. Microbiologically confirmed VAP occurred in 23 patients, 6 of 24 (25%) in the SSD group and 17 of 24 (70.83%) in the control group.Conclusion: The use of an ETT with intermittent SSD in a patient on MV helps to prevent ventilator associated pneumonia.Bangladesh Crit Care J March 2018; 6(1): 7-15
Title: A comparative study on prevention of ventilator associated pneumonia using endotracheal tube with or without intermittent subglottic secretion drainage device
Description:
Context: Ventilator-associated pneumonia (VAP) causes substantial morbidity and mortality.
The influence of intermittent subglottic secretion drainage (SSD) in preventing VAP has been supported by literature studies.
Objective: To find out the effectiveness of subglottic secretion drainage (SSD) on prevention of ventilator associated pneumonia (VAP) using endotracheal tube with subglottic secretion drainage (ETT-SSD).
Methodology: This study was carried out in the 10 beded medical-care Intensive Care Unit (ICU) of BIRDEM Hospital, Dhaka over a period of one and half year, enrolling 48 subjects.
Patients expected to require mechanical ventilation (MV) for more than >48 hrs were randomly assigned to one of two groups: one was ventilated with ETT-SSD and the other with conventional endotracheal tube (ETT-C).
Results: Primary outcome was the overall incidence of VAP based on quantitative culture of distal pulmonary samplings performed after each clinical suspicion.
Other outcomes included incidence of early and late onset VAP, duration of MV, duration of ICU stay and in hospital mortality.
Microbiologically confirmed VAP occurred in 23 patients, 6 of 24 (25%) in the SSD group and 17 of 24 (70.
83%) in the control group.
Conclusion: The use of an ETT with intermittent SSD in a patient on MV helps to prevent ventilator associated pneumonia.
Bangladesh Crit Care J March 2018; 6(1): 7-15.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Intermittent Subglottic Secretion Drainage and Ventilator-associated Pneumonia: A Multicenter Trial
Intermittent Subglottic Secretion Drainage and Ventilator-associated Pneumonia: A Multicenter Trial
Abstract
Rationale
Ventilator-associated pneumonia (VAP) causes substantial morbidity and mortality. The influence of sub...
Comparative study of the reliability of ultrasound to confirm the position of
endotracheal tube with cuff inflated with saline versus air
Comparative study of the reliability of ultrasound to confirm the position of
endotracheal tube with cuff inflated with saline versus air
Aim: To compare the reliability of transtracheal ultrasound to confirm the
endotracheal tube position with saline versus air inflated cuff. Methods: This was a
...
Learning endotracheal intubation with the Video Endotracheal Tube Guide
Learning endotracheal intubation with the Video Endotracheal Tube Guide
Introduction Video laryngoscopes facilitate the visualization of the glottis but do not guarantee endotracheal intubation due to difficulties in guiding the endotracheal tube to t...
Learning endotracheal intubation with the Video Endotracheal Tube Guide
Learning endotracheal intubation with the Video Endotracheal Tube Guide
Introduction Video laryngoscopes facilitate the visualization of the glottis but do not guarantee endotracheal intubation due to difficulties in guiding the endotracheal tube to t...
BACTERIOLOGY AND ANTIBIOTIC SENSITIVITY PATTERNS IN VENTILATOR-ASSOCIATED PNEUMONIA
BACTERIOLOGY AND ANTIBIOTIC SENSITIVITY PATTERNS IN VENTILATOR-ASSOCIATED PNEUMONIA
Background: Ventilator-Associated Pneumonia is the most common cause of hospital-acquired infections among patients admitted in Intensive Care Unit with mechanical ventilation. Ide...
A comparative study between I-gel and endotracheal tube in elective laparoscopic cholecystectomy surgeries under general anesthesia
A comparative study between I-gel and endotracheal tube in elective laparoscopic cholecystectomy surgeries under general anesthesia
Background: With increase in incidence of gall bladder stone the laparoscopic cholecystectomy preferred in various hospitals. Laryngoscopic stimulation of oropharyngeal and larynge...