Image registration is essential in treatment planning and position verification for highly radiation conformal delivery methods. The purpose of this study is to evaluate the accuracy of image registration in Varian Eclipse V. 8.6.17 and Oncentra V. 3.2.303 treatment planning system (TPS). Then the suitable image registration method of mutual information and match point between planning computed tomography and cone beam computed tomography are observed for 20 head and neck cases. The image registration verifications were performed in 2 TPSs using ImSim commercial QA software. The three set of images from ImSim commercial QA software, which the first one was stationary, the second set was 5, 10, 15 degree rotation and the third set was 5, 10, 15 mm translation in X, Y, and Z axes, were imported to Eclipse and Oncentra TPSs. The registration was made between the stationary and moving images. The registration errors were observed for mutual information and match point registration algorithms in each TPS. Then the planning CT image and cone beam CT image for 20 head and neck patients were registered on the Eclipse TPS by the mutual information and match point methods. The position shifts by the two methods were compared and evaluated with those registered optimization by radiation oncologist. For the registration of ImSim phantom, the Eclipse TPS shows slightly better registration than Oncentra TPS. The mutual information method demonstrates slightly less registration error than match point method, because pixel by pixel is used for mutual information while 4 points is selected for the match point registration method. The ImSim QA software can check both translation and rotation with no influence of setup position compared with the phantom or patient study. The registration error is increased when moving set is rotated >5 degree for all axes. For cone beam CT registration with planning CT of head and neck patients, the mean deviation from registered optimization by radiation oncologist for mutual information method are 2.02 ± 2.00 mm and 0.82 ± 1.16 degree and for match point method are 3.05 ± 2.92 mm and 1.31 ± 1.35 degree. The mutual information also shows superior image registration than match point method. From the result the mutual information and match point methods can assist the medical oncologist to optimize the image registration easily and reliably without image misalignment.
Office of Academic Resources, Chulalongkorn University
Title: Verification of image registration for the commercial treatmetn planning systems
Description:
Image registration is essential in treatment planning and position verification for highly radiation conformal delivery methods.
The purpose of this study is to evaluate the accuracy of image registration in Varian Eclipse V.
8.
6.
17 and Oncentra V.
3.
2.
303 treatment planning system (TPS).
Then the suitable image registration method of mutual information and match point between planning computed tomography and cone beam computed tomography are observed for 20 head and neck cases.
The image registration verifications were performed in 2 TPSs using ImSim commercial QA software.
The three set of images from ImSim commercial QA software, which the first one was stationary, the second set was 5, 10, 15 degree rotation and the third set was 5, 10, 15 mm translation in X, Y, and Z axes, were imported to Eclipse and Oncentra TPSs.
The registration was made between the stationary and moving images.
The registration errors were observed for mutual information and match point registration algorithms in each TPS.
Then the planning CT image and cone beam CT image for 20 head and neck patients were registered on the Eclipse TPS by the mutual information and match point methods.
The position shifts by the two methods were compared and evaluated with those registered optimization by radiation oncologist.
For the registration of ImSim phantom, the Eclipse TPS shows slightly better registration than Oncentra TPS.
The mutual information method demonstrates slightly less registration error than match point method, because pixel by pixel is used for mutual information while 4 points is selected for the match point registration method.
The ImSim QA software can check both translation and rotation with no influence of setup position compared with the phantom or patient study.
The registration error is increased when moving set is rotated >5 degree for all axes.
For cone beam CT registration with planning CT of head and neck patients, the mean deviation from registered optimization by radiation oncologist for mutual information method are 2.
02 ± 2.
00 mm and 0.
82 ± 1.
16 degree and for match point method are 3.
05 ± 2.
92 mm and 1.
31 ± 1.
35 degree.
The mutual information also shows superior image registration than match point method.
From the result the mutual information and match point methods can assist the medical oncologist to optimize the image registration easily and reliably without image misalignment.

Related Results

Shenzi 16-Inch Oil Export SCR CVA Verification
Shenzi 16-Inch Oil Export SCR CVA Verification
Abstract In 2006 Enterprise developed a 16-inch oil export system from Shenzi field located in Green Canyon Block 653 in the Gulf of Mexico, approximately 120 nau...
Platform Verification - Aview From Amember Of Industry
Platform Verification - Aview From Amember Of Industry
ABSTRACT Concerns have been raised in many sectors regarding the safety and reliability of offshore platforms. In this paper, the history of offshore operations a...
Double Exposure
Double Exposure
I. Happy Endings Chaplin’s Modern Times features one of the most subtly strange endings in Hollywood history. It concludes with the Tramp (Chaplin) and the Gamin (Paulette Godda...
Assessment of the Status of Birth Registration in Gamo Gofa Zone and Konso Woreda, SNNPR, Ethiopia
Assessment of the Status of Birth Registration in Gamo Gofa Zone and Konso Woreda, SNNPR, Ethiopia
Abstract Background: According to the monitoring results in Africa, the regional average completeness rate of birth registration has increased from around 40% to 56% from 2...
High-performance image registration algorithms for multi-core processors
High-performance image registration algorithms for multi-core processors
Deformable registration consists of aligning two or more 3D images into a common coordinate frame. Fusing multiple images in this fashion quantifies changes in organ shape, size, a...
Detection method of PCB component based on automatic optical stitching algorithm
Detection method of PCB component based on automatic optical stitching algorithm
Purpose – This paper aims to propose image stitching by reduction of full line and taking line image as registration image to solve the problem of automatic optic i...

Back to Top