Javascript must be enabled to continue!
Structural Optimization and Experimental Research of High-rise Guyed Tower
View through CrossRef
In this paper, the structural optimization of high-rise guyed tower is carried out for the guyed wire and tower column schemes. The schemes are compared from the four guyed wires and eight guyed wires, the width of the tower column, the uniform cross-section tower column and the variable cross-section tower column, etc. And the single-column tower with eight guyed wires and variable cross-section is recommended for the high-rise guyed tower. Through the full-scale test study of the high-rise guyed tower, the safety of the high-rise guyed tower structural optimization and the feasibility of engineering application are verified. According to the technical and economic analysis of traditional self-supporting towers and high-rise guyed towers recommended in this paper, it can be seen that the weight and total cost of the high-rise guyed towers are 75.3% and 88.5% of the traditional self-supporting towers respectively, demonstrating the technical and economic advantages of the high-rise guyed towers. The advantages and disadvantages of high-rise guyed towers and self-supporting towers are summarized for reference in engineering design.
Title: Structural Optimization and Experimental Research of High-rise Guyed Tower
Description:
In this paper, the structural optimization of high-rise guyed tower is carried out for the guyed wire and tower column schemes.
The schemes are compared from the four guyed wires and eight guyed wires, the width of the tower column, the uniform cross-section tower column and the variable cross-section tower column, etc.
And the single-column tower with eight guyed wires and variable cross-section is recommended for the high-rise guyed tower.
Through the full-scale test study of the high-rise guyed tower, the safety of the high-rise guyed tower structural optimization and the feasibility of engineering application are verified.
According to the technical and economic analysis of traditional self-supporting towers and high-rise guyed towers recommended in this paper, it can be seen that the weight and total cost of the high-rise guyed towers are 75.
3% and 88.
5% of the traditional self-supporting towers respectively, demonstrating the technical and economic advantages of the high-rise guyed towers.
The advantages and disadvantages of high-rise guyed towers and self-supporting towers are summarized for reference in engineering design.
Related Results
Corrosion analysis of guyed rod used for 500 kV transmission tower
Corrosion analysis of guyed rod used for 500 kV transmission tower
Abstract
As an important part of the guyed device of cable stayed tower, guyed rod plays a key role of preventing transmission tower from tilting and toppling. In th...
Model Test Of A Pile-Founded Guyed Tower
Model Test Of A Pile-Founded Guyed Tower
ABSTRACT
The development of structural concepts for deployment in deep waters has been actively pursued in the last decade by a number of oil operators and design...
Model Test of a Mooring System for a Pile-Founded Guyed Tower
Model Test of a Mooring System for a Pile-Founded Guyed Tower
ABSTRACT
The development of structural concepts for deployment in deep waters has been actively pursued in the 1ast decade by a number of oil operators and design...
VolturnUS 1:8-Scale FRP Floating Wind Turbine Tower: Analysis, Design, Testing and Performance
VolturnUS 1:8-Scale FRP Floating Wind Turbine Tower: Analysis, Design, Testing and Performance
In May of 2013 the VolturnUS 1:8 floating semi-submersible wind turbine was successfully deployed off the coast of Castine, Maine, making the unit the first grid connected offshore...
Influence of the Flexible Tower on Aeroelastic Loads of the Wind Turbine
Influence of the Flexible Tower on Aeroelastic Loads of the Wind Turbine
Based on the two-node Euler-Bernoulli beam, the tower system is discretized by finite element method, and the cubic Hermite polynomial is taken as the shape function of the beam el...
Influence of transmission tower load under extreme conditions during operation period on the stability of landslide and tower foundation
Influence of transmission tower load under extreme conditions during operation period on the stability of landslide and tower foundation
Abstract
Taking Yanzi landslide and 500 kV transmission tower foundations on the landslide as the research object, this paper presents a study of the influence of tr...
Parametric Design of Scroll-shaped Pylon of Single Tower Cable-stayed Bridge
Parametric Design of Scroll-shaped Pylon of Single Tower Cable-stayed Bridge
Using single-tower cable-stayed bridge as example, this article introduces the design and construction process of a cable-stayed bridge with a scroll-shaped tower, as well as the o...
Numerical Simulation of Impact Effect on Stability of Transmission Tower Foundation
Numerical Simulation of Impact Effect on Stability of Transmission Tower Foundation
The impact effect can cause structural damage to a transmission tower’s foundation and affect its overall stability. In order to study the influence of the impact effect on the sta...