“Dynamic Canthopexy” Drill Hole Canthal Repositioning
View through CrossRef
Abstract
Background
Canthopexies can be performed to modify the eye slant, both when the lateral canthus is lower than the medial one (congenital defect) or in case the patient asks for an almond-shaped eye (cosmetic indication).
Objectives
This peculiar type of canthopexy can be defined as “dynamic canthopexy,” meaning that the lateral canthus is released from its original insertion and raised to a higher position. The goal of this study is to demonstrate the differences and the efficacy of the dynamic cantoplasty.
Methods
The authors reviewed 30 patients treated with a “dynamic canthopexy” between January 2005 and March 2015. Eighteen patients were affected by true downslanting palpebral fissure, and 12 patients had a normal eye shape but were wishing for a more “Asian” look. Dynamic canthopexy involves a total modification of the canthal suspension system and its careful reconstruction at a higher level inside the orbital rim. To obtain a permanent result, canthal ligament and tendon had to be anchored to drill holes in the orbital rim bone with nonabsorbable sutures. Symmetry was very carefully assessed. The average surgical time was 1 hour.
Results
This surgery proved extremely effective in all cases. Patients must be warned, though, that an initial hypercorrection is necessary to achieve the desired canthal position. About 6 months after surgery the result of this operation can be considered permanent. Severe complications are rare.
Conclusions
Dynamic canthopexy can provide stable correction of anti-Mongolian slant. It can also be effectively employed to obtain permanent slant eyes when required by purely cosmetic patients. If precisely carried out, this technique can yield very rewarding outcomes.
Level of Evidence: 4
Oxford University Press (OUP)
Title: “Dynamic Canthopexy” Drill Hole Canthal Repositioning
Description:
Abstract
Background
Canthopexies can be performed to modify the eye slant, both when the lateral canthus is lower than the medial one (congenital defect) or in case the patient asks for an almond-shaped eye (cosmetic indication).
Objectives
This peculiar type of canthopexy can be defined as “dynamic canthopexy,” meaning that the lateral canthus is released from its original insertion and raised to a higher position.
The goal of this study is to demonstrate the differences and the efficacy of the dynamic cantoplasty.
Methods
The authors reviewed 30 patients treated with a “dynamic canthopexy” between January 2005 and March 2015.
Eighteen patients were affected by true downslanting palpebral fissure, and 12 patients had a normal eye shape but were wishing for a more “Asian” look.
Dynamic canthopexy involves a total modification of the canthal suspension system and its careful reconstruction at a higher level inside the orbital rim.
To obtain a permanent result, canthal ligament and tendon had to be anchored to drill holes in the orbital rim bone with nonabsorbable sutures.
Symmetry was very carefully assessed.
The average surgical time was 1 hour.
Results
This surgery proved extremely effective in all cases.
Patients must be warned, though, that an initial hypercorrection is necessary to achieve the desired canthal position.
About 6 months after surgery the result of this operation can be considered permanent.
Severe complications are rare.
Conclusions
Dynamic canthopexy can provide stable correction of anti-Mongolian slant.
It can also be effectively employed to obtain permanent slant eyes when required by purely cosmetic patients.
If precisely carried out, this technique can yield very rewarding outcomes.
Level of Evidence: 4.
Related Results
INNER AND OUTER INTERCANTHAL DISTANCES IN A NIGERIAN POPULATION
INNER AND OUTER INTERCANTHAL DISTANCES IN A NIGERIAN POPULATION
This study investigated the inner and outer intercanthal distances in a Nigeria population. Materials and Methods: The cross sectional study was carried on 384 adults (males and ...
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Abstract
Rotating drill pipe passing through dog-legs suffers fatigue damage due to cyclic bending stresses. Curves of the cumulative fatigue damage incurred in e...
Drillpipe Stress Distribution and Cumulative Fatigue Analysis in Complex Well Drilling: New Approach in Fatigue Optimization
Drillpipe Stress Distribution and Cumulative Fatigue Analysis in Complex Well Drilling: New Approach in Fatigue Optimization
Abstract
In the today high-cost and complex drilling environment, the importance of drillstring failure issue has dramatically reappeared, in spite of many manufa...
Mechanism and application of drill pipe bending induced borehole collapse in soft coal seam drilling
Mechanism and application of drill pipe bending induced borehole collapse in soft coal seam drilling
AbstractGas extraction drilling is a necessary measure for managing gas hazards. For soft coal seams where gas extraction drilling holes are prone to collapse, it is believed that ...
Hyoid bone position and upper airway patency: A computational finite element modeling study
Hyoid bone position and upper airway patency: A computational finite element modeling study
ABSTRACT
Background and Objectives
The hyoid bone’s inferior baseline position in obstructive sleep apnea (OSA) has led to surg...
Numerical analysis and Experimental Investigation of Lateral vibration on Drill String under Axial Load Constrained with Horizontal Pipe
Numerical analysis and Experimental Investigation of Lateral vibration on Drill String under Axial Load Constrained with Horizontal Pipe
Abstract
Horizontal well technology is an important means to improve drilling efficiency and oil and gas production, but it is easy to generate the lateral vibration...
Improved Formation Evaluation With Log-Test-Log Technique
Improved Formation Evaluation With Log-Test-Log Technique
Abstract
Formation evaluation has been greatly improved by obtaining the data from drill-stem testing and a series of logs with one trip in the hole. The log is run ...
The Application of Reverse Z-Plasty Design in Medial Canthal Skin Redundancy Reconstruction Surgery
The Application of Reverse Z-Plasty Design in Medial Canthal Skin Redundancy Reconstruction Surgery
Purpose:
To investigate the clinical outcomes of reverse Z-plasty in the reconstruction of epicanthal fold.
...