Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of the 0 h/1 h high-sensitivity cardiac troponin T algorithm in diagnosis of non-ST-segment elevation myocardial infarction (NSTEMI) in Han population

View through CrossRef
Abstract Objectives A rapid 0 h/1 h algorithm using high-sensitivity cardiac troponin T (hs-cTnT) for rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) is recommended by the European Society of Cardiology. We aim to prospectively evaluate the diagnostic performance of the algorithm in Chinese Han patients with suspected NSTEMI. Methods In this prospective diagnostic cohort study, 577 patients presenting to the emergency department with suspected NSTEMI and recent (<12 h) onset of symptoms were enrolled. The levels of serum hs-cTnT were measured on admission, 1 h later and 4–14 h later. All patients underwent the initial clinical assessment and were triaged into three groups (rule-out, rule-in and observe) according to the 0 h/1 h algorithm. The major cardiovascular events (MACE) were evaluated at the 7-day and 30-day follow-ups. Results Among 577 enrolled patients, NSTEMI was the final diagnosis for 106 (18.4%) patients. Based on the hs-cTnT 0 h/1 h algorithm, 148 patients (25.6%) were classified as rule-out, 278 patients (48.2%) as rule-in and 151 patients (26.2%) were assigned to the observe group. The rule-out approach resulted in a sensitivity of 100% and negative predictive value of 100%. The rule-in approach resulted in a specificity of 62.9% [95% CI (58.5–67.2%)] and positive predictive value of 37.1% [95%CI (31.3–42.8%)]. No MACE was observed in the rule-out group within 30-day follow-up. Conclusions The hs-cTnT 0 h/1 h algorithm is a safe tool for early rule-out of NSTEMI, while probably not an effective strategy for accurate rule-in of NSTEMI in Chinese Han population.
Title: Evaluation of the 0 h/1 h high-sensitivity cardiac troponin T algorithm in diagnosis of non-ST-segment elevation myocardial infarction (NSTEMI) in Han population
Description:
Abstract Objectives A rapid 0 h/1 h algorithm using high-sensitivity cardiac troponin T (hs-cTnT) for rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) is recommended by the European Society of Cardiology.
We aim to prospectively evaluate the diagnostic performance of the algorithm in Chinese Han patients with suspected NSTEMI.
Methods In this prospective diagnostic cohort study, 577 patients presenting to the emergency department with suspected NSTEMI and recent (<12 h) onset of symptoms were enrolled.
The levels of serum hs-cTnT were measured on admission, 1 h later and 4–14 h later.
All patients underwent the initial clinical assessment and were triaged into three groups (rule-out, rule-in and observe) according to the 0 h/1 h algorithm.
The major cardiovascular events (MACE) were evaluated at the 7-day and 30-day follow-ups.
Results Among 577 enrolled patients, NSTEMI was the final diagnosis for 106 (18.
4%) patients.
Based on the hs-cTnT 0 h/1 h algorithm, 148 patients (25.
6%) were classified as rule-out, 278 patients (48.
2%) as rule-in and 151 patients (26.
2%) were assigned to the observe group.
The rule-out approach resulted in a sensitivity of 100% and negative predictive value of 100%.
The rule-in approach resulted in a specificity of 62.
9% [95% CI (58.
5–67.
2%)] and positive predictive value of 37.
1% [95%CI (31.
3–42.
8%)].
No MACE was observed in the rule-out group within 30-day follow-up.
Conclusions The hs-cTnT 0 h/1 h algorithm is a safe tool for early rule-out of NSTEMI, while probably not an effective strategy for accurate rule-in of NSTEMI in Chinese Han population.

Related Results

Abstract 14211: Positive Predictive Value of Troponin for NSTEMI Based on Chief Complaint
Abstract 14211: Positive Predictive Value of Troponin for NSTEMI Based on Chief Complaint
Introduction: Serum troponin is a ubiquitous biomarker used to diagnose acute myocardial infarction (AMI). The positive predictive value (PPV) of high-sensitivity tropo...
Additional PKA phosphorylation sites in human cardiac troponin I
Additional PKA phosphorylation sites in human cardiac troponin I
We used mass spectrometry to monitor cAMP‐dependent protein kinase catalysed phosphorylation of human cardiac troponin I in vitro. Phosphorylation of isolated troponin I by cAMP‐de...
Study of Ischemia Modified Albumin as New Potential Diagnostic Biomarker In Acute Myocardial Infarction.
Study of Ischemia Modified Albumin as New Potential Diagnostic Biomarker In Acute Myocardial Infarction.
Background: Because of the varied presentation and associated high mortality the identification of patients with acute myocardial infarction is very critical for the patient manage...
Misleading Elevation of Troponin T caused by Polymyositis
Misleading Elevation of Troponin T caused by Polymyositis
Background: Elevations of cardiac enzymes are commonly used to indicate myocardial ischemia, but they can be elevated due to other conditions. Different forms of Troponin (cTnT, sT...
Severity of Coronary Artery Disease in Patients of NSTEMI Associated With Elevated Troponin Levels
Severity of Coronary Artery Disease in Patients of NSTEMI Associated With Elevated Troponin Levels
Non-ST-segment elevation myocardial infarction (NSTEMI) is more communal than ST-segment elevation myocardial infarction (STEMI), and statistics on the coexistence of severe corona...

Back to Top