A Monte Carlo simulation of tritium β particle motion in a matrix material indicates that the probability of escape through the material surface is greater than 50% for near-surface tritium, but drops quite rapidly with increasing depth. Beyond an areal density depth of 2×10−5 g/cm2, the decline is close to exponential, with an e-folding length of approximately 3×10−5 g/cm2, the exact value varying slightly with the material. The sensitivity of the tritium imaging technique will decrease at a similar rate with increasing depth of tritium. Experimentally, the image intensity of a tritium-implanted graphite specimen was observed to decrease exponentially with coating thickness as an aluminum layer was evaporated onto its surface, with an exponent that was within 30% of the predicted value. The Monte Carlo simulation also indicated that the limit of lateral resolution of the tritium imaging technique will be slightly less than the depth of the tritium, subject always to Recknagel’s limit of resolution due to “chromatic aberration” of the electron optics, which is of the order of 200 nm. If tritium is uniformly distributed through the material, surface tritium so dominates image formation that Recknagel’s limit inevitably applies.
Title: Tritium depth dependence of tritium imaging
Description:
A Monte Carlo simulation of tritium β particle motion in a matrix material indicates that the probability of escape through the material surface is greater than 50% for near-surface tritium, but drops quite rapidly with increasing depth.
Beyond an areal density depth of 2×10−5 g/cm2, the decline is close to exponential, with an e-folding length of approximately 3×10−5 g/cm2, the exact value varying slightly with the material.
The sensitivity of the tritium imaging technique will decrease at a similar rate with increasing depth of tritium.
Experimentally, the image intensity of a tritium-implanted graphite specimen was observed to decrease exponentially with coating thickness as an aluminum layer was evaporated onto its surface, with an exponent that was within 30% of the predicted value.
The Monte Carlo simulation also indicated that the limit of lateral resolution of the tritium imaging technique will be slightly less than the depth of the tritium, subject always to Recknagel’s limit of resolution due to “chromatic aberration” of the electron optics, which is of the order of 200 nm.
If tritium is uniformly distributed through the material, surface tritium so dominates image formation that Recknagel’s limit inevitably applies.
Related Results
Tritium contaminated soil in sites for Semipalatinsk above-ground nuclear tests
Tritium contaminated soil in sites for Semipalatinsk above-ground nuclear tests
Semipalatinsk above-ground nuclear tests caused atmospheric fallout and radioactive contam-ination of the environment that resulted in the synthesis of great amount of radioisotope...
Embedding optimization reveals long-lasting history dependence in neural spiking activity
Embedding optimization reveals long-lasting history dependence in neural spiking activity
AbstractInformation processing can leave distinct footprints on the statistics of neural spiking. For example, efficient coding minimizes the statistical dependencies on the spikin...
The Road to Achieving Business Value With Reflection Sonic Imaging
The Road to Achieving Business Value With Reflection Sonic Imaging
Reflection sonic imaging has been around for decades. However, there are still open questions on the range of applications and what can be really taken to the bank to impact our bu...
TU‐B‐201‐03: Accounting for MV Imaging Dose and the Future of MV Imaging
TU‐B‐201‐03: Accounting for MV Imaging Dose and the Future of MV Imaging
Radiotherapy is in the era of image guided radiation therapy (IGRT) in which imaging procedures are routinely performed for patient positioning, and target localization. The additi...
Harmonizing and Optimizing CT Perfusion Stroke Imaging
Harmonizing and Optimizing CT Perfusion Stroke Imaging
This thesis focuses on harmonizing and optimizing CT perfusion (CTP) imaging for stroke. CTP imaging can help select patients with ischemic stroke for thrombectomy. However, due to...
TRITIUM DETERMINATION FROM WINE SAMPLES USING LIQUID SCINTILLATION COUNTING
TRITIUM DETERMINATION FROM WINE SAMPLES USING LIQUID SCINTILLATION COUNTING
Tritium measurement from aqueous fraction of the wines of known vineyard can be a useful tool in reconstruction of the tritium activity in different areas and makes possible to dat...
Naloxone Knowledge, Carrying, Purchase, and Use
Naloxone Knowledge, Carrying, Purchase, and Use
ImportanceWidespread naloxone access is a key policy response to the opioid crisis. Naloxone availability is typically estimated from pharmacy sales, which exclude naloxone provide...
Depth-aware salient object segmentation
Depth-aware salient object segmentation
Object segmentation is an important task which is widely employed in many computer vision applications such as object detection, tracking, recognition, and ret...