An engineered biosensor enables dynamic aspartate measurements in living cells
View through CrossRef
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, highlighting the need for robust tools to measure aspartate abundance. However, comprehensive understanding of aspartate metabolism has been limited by the throughput, cost, and static nature of the mass spectrometry (MS)-based measurements that are typically employed to measure aspartate levels. To address these issues, we have developed a green fluorescent protein (GFP)-based sensor of aspartate (jAspSnFR3), where the fluorescence intensity corresponds to aspartate concentration. As a purified protein, the sensor has a 20-fold increase in fluorescence upon aspartate saturation, with dose-dependent fluorescence changes covering a physiologically relevant aspartate concentration range and no significant off target binding. Expressed in mammalian cell lines, sensor intensity correlated with aspartate levels measured by MS and could resolve temporal changes in intracellular aspartate from genetic, pharmacological, and nutritional manipulations. These data demonstrate the utility of jAspSnFR3 and highlight the opportunities it provides for temporally resolved and high-throughput applications of variables that affect aspartate levels.
eLife Sciences Publications, Ltd
Title: An engineered biosensor enables dynamic aspartate measurements in living cells
Description:
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, highlighting the need for robust tools to measure aspartate abundance.
However, comprehensive understanding of aspartate metabolism has been limited by the throughput, cost, and static nature of the mass spectrometry (MS)-based measurements that are typically employed to measure aspartate levels.
To address these issues, we have developed a green fluorescent protein (GFP)-based sensor of aspartate (jAspSnFR3), where the fluorescence intensity corresponds to aspartate concentration.
As a purified protein, the sensor has a 20-fold increase in fluorescence upon aspartate saturation, with dose-dependent fluorescence changes covering a physiologically relevant aspartate concentration range and no significant off target binding.
Expressed in mammalian cell lines, sensor intensity correlated with aspartate levels measured by MS and could resolve temporal changes in intracellular aspartate from genetic, pharmacological, and nutritional manipulations.
These data demonstrate the utility of jAspSnFR3 and highlight the opportunities it provides for temporally resolved and high-throughput applications of variables that affect aspartate levels.
Related Results
Release and fixation of CO2 by guinea-pig kidney tubules metabolizing aspartate
Release and fixation of CO2 by guinea-pig kidney tubules metabolizing aspartate
1. The metabolism of L-[U-14C]aspartate, L-[1-14C]aspartate and L-[4-14C]aspartate was studied in isolated guinea-pig kidney tubules. 2. Oxidation of C-1 plus that of C-4 of aspart...
An engineered biosensor enables dynamic aspartate measurements in living cells
An engineered biosensor enables dynamic aspartate measurements in living cells
Abstract
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, hi...
An engineered biosensor enables dynamic aspartate measurements in living cells
An engineered biosensor enables dynamic aspartate measurements in living cells
Abstract
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, hi...
An engineered biosensor enables dynamic aspartate measurements in living cells
An engineered biosensor enables dynamic aspartate measurements in living cells
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, highlighting the need for r...
An engineered biosensor enables dynamic aspartate measurements in living cells
An engineered biosensor enables dynamic aspartate measurements in living cells
Abstract
Intracellular levels of the amino acid aspartate are responsive to changes in metabolism in mammalian cells and can correspondingly alter cell function, hi...
Opening up "containment": Technological and social dimensions of biocontainment for genetically engineered organisms designed for deliberate release
Opening up "containment": Technological and social dimensions of biocontainment for genetically engineered organisms designed for deliberate release
Advances in engineering biology, together with growing interest and investment in supporting a bio-based economy in the US, are fueling research and development efforts into geneti...
Engineering of a biosensor for intracellular aspartate
Engineering of a biosensor for intracellular aspartate
ABSTRACT
Aspartate is a limiting metabolite in proliferating cells with its production closely linked to glutamine and mitochondrial metabolism. To date, measuring ...
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
Human tissues comprise trillions of cells that populate a complex space of molecular phenotypes and functions and that vary in abundance by 4–9 orders of magnitude. Relying solely ...