Operating principles of peristaltic pumping through a dense array of valves
View through CrossRef
Immersed nonlinear elements are prevalent in biological systems that require a preferential flow direction, such as the venous and the lymphatic system. We investigate here a certain class of models where the fluid is driven by peristaltic pumping and the nonlinear elements are ideal valves that completely suppress backflow. This highly nonlinear system produces discontinuous solutions that are difficult to study. We show that, as the density of valves increases, the pressure and flow are well approximated by a continuum of valves which can be analytically treated, and we demonstrate through numeric simulation that the approximation works well even for intermediate valve densities. We find that the induced flow is linear in the peristaltic amplitude for small peristaltic forces and, in the case of sinusoidal peristalsis, is independent of pumping direction. Despite the continuum approximation used, the physical valve density is accounted for by modifying the resistance of the fluid appropriately. The suppression of backflow causes a net benefit in adding valves when the valve density is low, but once the density is high enough, valves predominately suppress forward flow, suggesting there is an optimum number of valves per wavelength. The continuum model for peristaltic pumping through an array of valves presented in this work can eventually provide insights about the design and operating principles of complex flow networks with a broad class of nonlinear elements.
Title: Operating principles of peristaltic pumping through a dense array of valves
Description:
Immersed nonlinear elements are prevalent in biological systems that require a preferential flow direction, such as the venous and the lymphatic system.
We investigate here a certain class of models where the fluid is driven by peristaltic pumping and the nonlinear elements are ideal valves that completely suppress backflow.
This highly nonlinear system produces discontinuous solutions that are difficult to study.
We show that, as the density of valves increases, the pressure and flow are well approximated by a continuum of valves which can be analytically treated, and we demonstrate through numeric simulation that the approximation works well even for intermediate valve densities.
We find that the induced flow is linear in the peristaltic amplitude for small peristaltic forces and, in the case of sinusoidal peristalsis, is independent of pumping direction.
Despite the continuum approximation used, the physical valve density is accounted for by modifying the resistance of the fluid appropriately.
The suppression of backflow causes a net benefit in adding valves when the valve density is low, but once the density is high enough, valves predominately suppress forward flow, suggesting there is an optimum number of valves per wavelength.
The continuum model for peristaltic pumping through an array of valves presented in this work can eventually provide insights about the design and operating principles of complex flow networks with a broad class of nonlinear elements.
Related Results
Design, Fabrication, and Evaluation of a Biomimetic Soft Peristaltic Pump for Biomedical Applications
Design, Fabrication, and Evaluation of a Biomimetic Soft Peristaltic Pump for Biomedical Applications
Peristaltic pumping can be observed in biological organs which contain hollow tubular cavities, including intestines, esophagus, and ureter [1, 2]. These act as positive d...
Short Intussusception Valves Prevent Reflux After Jejunal Interposition Bilioduodenal Anastomosis
Short Intussusception Valves Prevent Reflux After Jejunal Interposition Bilioduodenal Anastomosis
Short whole circumference and semi‐circumference intussusception valves were created in interposition
cholecysto‐jejunal‐duodenal conduits in pigs to determine which method best pr...
Subsurface Safety Valves
Subsurface Safety Valves
ABSTRACT
Because most of our company's production is in open water of navigable channels, management has been vitally concerned about controlling offshore wells i...
Research on mechanical characteristics and safety of working platform in rod pumping process
Research on mechanical characteristics and safety of working platform in rod pumping process
Rod pumping on offshore platform provides a solution to low efficient extraction of offshore heavy oil and the safety of working platform is the prerequisite for the implementation...
Numerical modeling the impacts of increasing groundwater pumping upon discharge decline of the BL Spring located in Xilin Gol League in east inner Mongolia, China
Numerical modeling the impacts of increasing groundwater pumping upon discharge decline of the BL Spring located in Xilin Gol League in east inner Mongolia, China
Spring discharge decline induced by increasing groundwater pumping under the background of increasing water demand for agricultural, industrial, and domestic utilizations has been ...
Reliability assessment of mobile pumping units
Reliability assessment of mobile pumping units
An analytical formula for determining the mathematical expectation and variance is derived . functions reliability mobile pumping units, allowing evaluate residual development With...
Numerical study of two-dimensional peristaltic flows
Numerical study of two-dimensional peristaltic flows
The Navier–Stokes equations are solved numerically for two-dimensional peristaltic flows by using the finite-difference technique employing the upwind SOR method, and the velocity,...
Carrier-to-Noise Ratio for Distributed Raman Amplifiers with Different Pumping Configurations
Carrier-to-Noise Ratio for Distributed Raman Amplifiers with Different Pumping Configurations
Distributed Raman amplifiers (DRAs) achieve higher bit rate, low noise figure, a decreased nonlinear penalty, long-haul transmission, small channel spacing and operating near zero ...