Javascript must be enabled to continue!
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
View through CrossRef
Abstract
Objective. Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination. Approach. A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μm and 100 ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.4 MeV protons. Main results. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09% and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT. Significance. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
Title: First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Description:
Abstract
Objective.
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body.
Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector.
This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination.
Approach.
A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μm and 100 ps, respectively.
Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET).
With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.
4 MeV protons.
Main results.
Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.
09% and 51.
12%.
Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT.
Significance.
While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT.
Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
Related Results
Flight Reservation System
Flight Reservation System
Flight reservation System is a computerized system used to store and retrieve information and conduct transactions related to air travel. The project is aimed at exposing the relev...
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography in the diagnosis of bacteriologically confirmed pulmonary tuberculosis in hospitalised Xpert MTB/RIF-negative patients
The role of chest radiography to diagnose active tuberculosis in symptomatic patients who have a negative Xpert MTB/RIF (Xpert) test result is unclear. This study aimed to assess t...
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Orthopedic Injury Diagnosis Using Digital Radiography: A Retrospective Study
Background: Hundred patients were examined to determine the effectiveness of digital radiography in detecting Orthopedic injuries. The decisive findings showed that digital radiogr...
Geomorphology and geochronology of the coseismic? Emad Deh rock avalanche of the Zagros MountainsGeomorphology and geochronology of the coseismic? Emad Deh rock avalanche of the Zagros Mountains
Geomorphology and geochronology of the coseismic? Emad Deh rock avalanche of the Zagros MountainsGeomorphology and geochronology of the coseismic? Emad Deh rock avalanche of the Zagros Mountains
<p>This work documents for the first time the prehistoric, but morphologically pristine, Emad Deh rock avalanche, located in the Fars Arc of the Zagros Mountains. The...
Triggering Mechanisms of Gayari Avalanche, Pakistan
Triggering Mechanisms of Gayari Avalanche, Pakistan
Abstract
A massive snow avalanche occurred on April, 2012 at Gayari, located in NE part of Pakistan, close to India and China Border. The catastrophic avalanche killed near...
THE MODERN MEDIUM-SCALE MAPPING OF THE AVALANCE DANGER IN THE UKRAINIAN CARPATHIANS
THE MODERN MEDIUM-SCALE MAPPING OF THE AVALANCE DANGER IN THE UKRAINIAN CARPATHIANS
There is a characteristic phenomenon of mountain landscape in Avalanche. Mountain development entails the need to take into account the avalanche hazard. The important task of the ...
Avalanche Susceptibility mapping of District Shigar, Pakistan using GIS-based MCDA–AHP modeling
Avalanche Susceptibility mapping of District Shigar, Pakistan using GIS-based MCDA–AHP modeling
Abstract
In snow-covered mountainous terrain like the Himalayas, avalanches are responsible for the majority of fatalities and property damage. Statistics and information o...
Mechanosensory cephalic bristles mediate rapid flight initiation in endothermic hawkmoths
Mechanosensory cephalic bristles mediate rapid flight initiation in endothermic hawkmoths
AbstractEndothermic insects including bees, butterflies, and moths need to warm up their flight muscles before taking flight. For instance, diurnal butterflies bask in the sun to h...

