Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Variability in venous gas emboli following the same dive at 3,658 meters

View through CrossRef
Update: originally posted in Vol 48 #2 Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.e., venous gas emboli [VGE]). Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules. However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.S. Navy Diving Manual (Rev. 7). Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet. Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the cross correction method) for 30 minutes in a hyperbaric chamber. All dives were completed following a 60-minute exposure at 12,000 feet. Following the dive, the chamber was decompressed back to altitude for two hours. Echocardiograph measurements were performed every 20 minutes post-dive. Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively. No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude. Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4. Using the cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.
Title: Variability in venous gas emboli following the same dive at 3,658 meters
Description:
Update: originally posted in Vol 48 #2 Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.
e.
, venous gas emboli [VGE]).
Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules.
However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.
S.
Navy Diving Manual (Rev.
7).
Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet.
Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the cross correction method) for 30 minutes in a hyperbaric chamber.
All dives were completed following a 60-minute exposure at 12,000 feet.
Following the dive, the chamber was decompressed back to altitude for two hours.
Echocardiograph measurements were performed every 20 minutes post-dive.
Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively.
No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude.
Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4.
Using the cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.

Related Results

Abstract P3-01-08: Infiltrating immune cells in the tumor emboli of inflammatory breast cancer
Abstract P3-01-08: Infiltrating immune cells in the tumor emboli of inflammatory breast cancer
Abstract INTRODUCTION: Inflammatory breast cancer (IBC) is a rare and aggressive type of locally advanced breast cancer. The hallmark of IBC is the presence of E-Cad...
Variability in venous gas emboli following the same dive at 3,658 meters
Variability in venous gas emboli following the same dive at 3,658 meters
Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bub...
Effect of Lactiplantibacillus plantarum LPJZ-658 on caecum microbiota and serum metabolomics of Luhua broiler
Effect of Lactiplantibacillus plantarum LPJZ-658 on caecum microbiota and serum metabolomics of Luhua broiler
IntroductionThe purpose of this study was to investigate the effects of dietary supplementation of Lactiplantibacillus plantarum LPJZ-658 on body weight and serum indexes of Luhua ...
Underwater pulse oximetry reveals increased rate of arterial oxygen desaturation across repeated freedives to 11 metres of freshwater
Underwater pulse oximetry reveals increased rate of arterial oxygen desaturation across repeated freedives to 11 metres of freshwater
Introduction: Recreational freedivers typically perform repeated dives to moderate depths with short recovery intervals. According to freediving standards, these recovery intervals...
First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel
First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel
Germonpré P, Van der Eecken P, Van Renterghem E, Germonpré F-L, Balestra C. First impressions: Use of the Azoth Systems O’Dive subclavian bubble monitor on a liveaboard dive vessel...
Decompression at 1.3 versus 1.6 bar and Nitrogen Elimination and Venous Gas Emboli: A Randomized Controlled Trial
Decompression at 1.3 versus 1.6 bar and Nitrogen Elimination and Venous Gas Emboli: A Randomized Controlled Trial
Plogmark O, Hjelte C, Olsson M, Ekström M, Frånberg O. Decompression at 1.3 versus 1.6 bar and Nitrogen Elimination and Venous Gas Emboli: A Randomized Controlled Trial. Undersea H...
Gamma Camera Detection of Experimental Pulmonary Emboli After Peripheral Injection of Indium-111 Labeled Platelets
Gamma Camera Detection of Experimental Pulmonary Emboli After Peripheral Injection of Indium-111 Labeled Platelets
A simple, noninvasive method for the direct visualization of pulmonary emboli would be of considerable value for the diagnosis of this common disorder, especially in patients who h...
Comparisons of Pore Structure for Unconventional Tight Gas, Coalbed Methane and Shale Gas Reservoirs
Comparisons of Pore Structure for Unconventional Tight Gas, Coalbed Methane and Shale Gas Reservoirs
Extended abstract Tight sands gas, coalbed methane and shale gas are three kinds of typical unconventional natural gas. With the decrease of conventional oil and gas...

Back to Top