A Vicarious Calibration of the Probe-1 Hyperspectral Sensor

View through CrossRef
Analysis of Probe-1 hyperspectral data obtained during July 1998 revealed that neither the spectroscopic nor the radiometric laboratory calibrations supplied with the data were applicable, presumably because the sensor had suffered an undocumented opto-mechanical realignment between the calibration and the flight. In this paper the calculation of a new set of calibration coefficients is described, based upon the simultaneous acquisition of high-resolution GER3700 field spectra for a calibration site within the Probe-1 image. For the calibration calculations, an average ground-based reflectance spectrum for the target area was convolved and resampled to match the spectral characteristics of the Probe-1 sensor. The MODTRAN3 radiative-transfer code was used to correct the Probe-1 radiance spectra to surface reflectance, and an iterative numerical technique was applied to adjust the Probe-1 radiometric coefficients, to reduce the absolute reflectance difference between the GER3700 and Probe-1 spectra for the calibration site to 0.02 percent. This technique for the vicarious calibration of hyperspectral data has been implemented into the Imaging Spectrometer and Data Analysis System developed at the Canada Centre for Remote Sensing (CCRS).
Natural Resources Canada/CMSS/Information Management
Title: A Vicarious Calibration of the Probe-1 Hyperspectral Sensor
Description:
Analysis of Probe-1 hyperspectral data obtained during July 1998 revealed that neither the spectroscopic nor the radiometric laboratory calibrations supplied with the data were applicable, presumably because the sensor had suffered an undocumented opto-mechanical realignment between the calibration and the flight.
In this paper the calculation of a new set of calibration coefficients is described, based upon the simultaneous acquisition of high-resolution GER3700 field spectra for a calibration site within the Probe-1 image.
For the calibration calculations, an average ground-based reflectance spectrum for the target area was convolved and resampled to match the spectral characteristics of the Probe-1 sensor.
The MODTRAN3 radiative-transfer code was used to correct the Probe-1 radiance spectra to surface reflectance, and an iterative numerical technique was applied to adjust the Probe-1 radiometric coefficients, to reduce the absolute reflectance difference between the GER3700 and Probe-1 spectra for the calibration site to 0.
02 percent.
This technique for the vicarious calibration of hyperspectral data has been implemented into the Imaging Spectrometer and Data Analysis System developed at the Canada Centre for Remote Sensing (CCRS).

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Penerapan Prinsip Vicarious Liability dalam Pertanggungjawaban Perseroan Terbatas
Penerapan Prinsip Vicarious Liability dalam Pertanggungjawaban Perseroan Terbatas
AbstractA limited liability company is a legal subject capable of being responsible for the risks in carrying out its business. The principle of vicarious liability is the basis of...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Numerical Investigation of the Reynolds Number Effect on Five-Hole Probe Calibration
Numerical Investigation of the Reynolds Number Effect on Five-Hole Probe Calibration
Five-hole probes are widely used in turbomachinery applications. However, the Reynolds number dependence of the probe calibration has not received enough attention. The experimenta...
Vicarious Dissonance : Meta-analysis
Vicarious Dissonance : Meta-analysis
Vicarious dissonance is the phenomenon that describes the possibility that individuals may experience cognitive dissonance vicariously when they witness an inconsistent act committ...
Vicarious Dissonance : Meta-analysis
Vicarious Dissonance : Meta-analysis
Vicarious dissonance is the phenomenon that describes the possibility that individuals may experience cognitive dissonance vicariously when they witness an inconsistent act committ...
Learned Hyperspectral Compression Using a Student’s T Hyperprior
Learned Hyperspectral Compression Using a Student’s T Hyperprior
Hyperspectral compression is one of the most common techniques in hyperspectral image processing. Most recent learned image compression methods have exhibited excellent rate-distor...
Mapping Mineralogical Distributions on Mars with Unsupervised Machine Learning
Mapping Mineralogical Distributions on Mars with Unsupervised Machine Learning
Abstract Knowledge of the constituents of the Martian surface and their distributions over the planet informs us about Mars’ geomorphological formation and evolutionary h...

Back to Top