Research and development of UHV AC transformer and shunt reactor
View through CrossRef
SUMMARYThe Jingdongnan‐Nanyang‐Jingmen UHV AC Pilot Project has already been put into service in China. In this paper, insulation level of power transformer and shunt reactor for 1000 kV power transmission project in China are introduced. UHV AC transformer and shunt reactor structures are given. Key technologies, including cooling type, regulating method for UHV AC transformer, pattern of outgoing line, and noise controlling, are discussed. Besides, due to the high voltage class, high capacity, and super size of UHV power transformer, the size of its test circuit is correspondingly enlarged, the impacts of stray inductance and capacitance will be more intense consequentially, thus in factory test including lighting impulse test, switching impulse voltage test, short‐duration induced AC voltage test at 500 kV side, and long‐duration induced AC voltage test with partial discharge measurement are presented. Copyright © 2011 John Wiley & Sons, Ltd.
Title: Research and development of UHV AC transformer and shunt reactor
Description:
SUMMARYThe Jingdongnan‐Nanyang‐Jingmen UHV AC Pilot Project has already been put into service in China.
In this paper, insulation level of power transformer and shunt reactor for 1000 kV power transmission project in China are introduced.
UHV AC transformer and shunt reactor structures are given.
Key technologies, including cooling type, regulating method for UHV AC transformer, pattern of outgoing line, and noise controlling, are discussed.
Besides, due to the high voltage class, high capacity, and super size of UHV power transformer, the size of its test circuit is correspondingly enlarged, the impacts of stray inductance and capacitance will be more intense consequentially, thus in factory test including lighting impulse test, switching impulse voltage test, short‐duration induced AC voltage test at 500 kV side, and long‐duration induced AC voltage test with partial discharge measurement are presented.
Copyright © 2011 John Wiley & Sons, Ltd.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Ventriculoportal Shunt, a New Transomphalic Extraperitoneal Surgical Technique in Treatment of Hydrocephalus
Ventriculoportal Shunt, a New Transomphalic Extraperitoneal Surgical Technique in Treatment of Hydrocephalus
Aim. The aim of this article was to report a new transomphalic extraperitoneal surgical technique for treatment of hydrocephalus, called ventriculoportal shunt. Materials and Metho...
<b>COMPARISON OF SUCCESS RATE OF FRONTAL VERSUS OCCIPITAL ENTRY SITE FOR VENTRICULOPERITONEAL SHUNT INSERTION IN PATIENTS WITH HYDROCEPHALUS</b>
<b>COMPARISON OF SUCCESS RATE OF FRONTAL VERSUS OCCIPITAL ENTRY SITE FOR VENTRICULOPERITONEAL SHUNT INSERTION IN PATIENTS WITH HYDROCEPHALUS</b>
Background: Hydrocephalus is a common neurological disorder characterized by an abnormal accumulation of cerebrospinal fluid within the brain ventricles. Surgical interventions, su...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
Role of intrathecal and topical vancomycin in prevention of ventriculoperitoneal shunt infections
Role of intrathecal and topical vancomycin in prevention of ventriculoperitoneal shunt infections
The objective of this study is to assess the role of intrathecal and topical vancomycin in the prevention of ventriculoperitoneal shunt infection. Infections of the ventriculoperit...
Ventriculoperitoneal Shunt versus Endoscopic Third Ventriculostomy in the treatment of Obstructive Hydrocephalus in Pediatric Midline Posterior Fossa tumors
Ventriculoperitoneal Shunt versus Endoscopic Third Ventriculostomy in the treatment of Obstructive Hydrocephalus in Pediatric Midline Posterior Fossa tumors
Abstract
Background
Treatment of secondary hydrocephalus due to posterior fossa tumors in these children is still a matter of co...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...